Packing uses for

The styrene-divinylbenzene matrix of the Styragel packings is chemically very inert, which makes this family of packings useful for a broad range of applications. The chromatographic conditions for the analysis of many polymers have been worked out in detail. A more specific discussion of the solvents recommended for the different polymer types is included in Section III,A,4. [Pg.327]

Figure 9-6RR. Intalox Grid-type packing useful for fouling, solids and heat transfer high-strength, low-pressure drop, high capacity, better efficiency than most structured and random packing. Used by permission of Norton Chemical Process Products Corp., Bull. IG-1. Figure 9-6RR. Intalox Grid-type packing useful for fouling, solids and heat transfer high-strength, low-pressure drop, high capacity, better efficiency than most structured and random packing. Used by permission of Norton Chemical Process Products Corp., Bull. IG-1.
A Norton [139] correlation for modern, random dumped packings used for distillation up to 200 psia is (use high performance internal distributors and supports) from surface tension of 4 dynes/cm but less than 33, and liquid viscosity of at least 0.83 to 0.08 cps but not greater ... [Pg.378]

Heats of solution are the basis for instant cold packs and instant hot packs used for the first-aid treatment of minor sprains and pulled muscles. These packs have two separate compartments. One contains water, and the other contains a salt NH4 NO3 for cold packs and MgSO. or CaCl2 for hot packs. Kneading the pack breaks the wall between the compartments, allowing the salt to mix with water. As the salt dissolves to form an aqueous solution, the temperature of the pack changes. Heat is absorbed or released only as the salt dissolves, however, so after all of the salt has dissolved, the pack gradually returns to room temperature. Further manipulation of the pack has no effect. [Pg.849]

Unlike the pellicular packings used for ion exchange, the packings used in ion exclusion are derived from totally sulphonated polymeric materials. Separation is dependent upon three different mechanisms Donnan exclusion, steric exclusion and adsorption/partitioning. [Pg.44]

The column packings used for SEC must be compatible with aqueous mobile phases and therefore must be hydrophilic in nature. The support surface must be inert to minimize interactions with protein analytes. The packing must be available in pore sizes suitable for permeation of a wide range of proteins, and the pores should be uniform in diameter. Because the separation only takes place within the pore system, the porosity of the packing should be as large as possible. The support material should be chemically compatible with SEC mobile phases and mechanically stable under high flow rates and pressures. [Pg.98]

The technique of Gel Permeation Chromatography (GPC) was Introduced by Moore and Hendrickson (1,2 ) in 1964 for determining molecular weight distributions of polymer samples. The chromatographic column packings used for this new technique consisted of porous spheres of crossllnked styrene-divlnyl benzene resins (37-75ym) that were subsequently available as a family of columns under the name Styragel. Analytical column dimensions were 7.8 mm I.D. X 4 ft (122 cm). [Pg.47]

Wang and Li have reported the determination of procaine hydrochloride injections, and the quality control of 4-aminobenzoic acid [144]. The column packing used for this work consisted of 8 g of silanized siliceous earth support with 5 mL of hexanol as the stationary phase, previously percolated with 20 mL of 0.05 M sodium carbonate. The drug injection solution (containing 10 mg of procaine hydrochloride) was applied to the column, and eluted with 30 mL of 0.05 M sodium carbonate. The eluent was diluted to 50 mL with water, and 4-aminobenzoic acid was determined by an absorbance measurement at 266 nm. Procaine was then eluted from the column using 60 mL of 0.1 M hydrochloric acid. This eluent was treated with 10 mL of acetate buffer (pH 6), and diluted to 100 ml with water. The analyte was determined on the basis of its absorbance at 290 nm. Equations for the computation of procaine and 4-aminobenzoic acid concentrations were presented. [Pg.441]

Cartridge Column—Disposable off-line tube packed with >1 g of packing used for sample and solvent preparation. (See SFE and Windowing.)... [Pg.214]

TMS Si-O-Si-C Methyl, CH3 Bonded, reverse Tetramethylsilane lowest resolution of reverse phase packings useful for survey separations and... [Pg.131]

Heat packs Packs used for first aid purposes by giving off heat. [Pg.62]

The appropriate smoke flavouring for canned fish or seafood will be dependent upon the liquid system used in canning the product. With water-packed canned fish, aqueous smoked flavourings can be added directly to the canning solution used to pack the fish. Steaks or fillets can be marinated in an oil-based smoke flavouring for 48 hours and then canned. An alternative method of application would be the addition of an oil-based smoke flavour in the oil pack used for canning fish or seafood products. [Pg.305]

A typical HPLC column is a stainless steel tube filled with small-particle packing used for sample separation. HPLC columns can be categorized in a number of ways ... [Pg.48]

There are two popular stationary-phase materials. Polystyrene-divinylben-zene resins are useful materials, and the pore size can be easily controlled by the amount of divinylbenzene crosslinking. Silica and derivatized silica are also heavily used, and provide better mechanical rigidity. The problem with these and all packings used for SEC is to find a material that will be tmly inert to all chemical interactions with the solutes. [Pg.147]

Sieve-tray towers are very effective, both with respect to liquid-handling capacity and extraction efficiency, particularly for systems of low interfacial tension which do not require mechanical agitation for good dispersion. The general assembly of plates and downspouts is much the same as for gas-liquid contact except that a weir is not required. Towers packed with the same random packing used for gas-liquid contact have also been used for liquid extractors however, mass-transfer rates are poor. It is recommended instead that sieve-tray towers be used for systems of low interfacial tension and mechanically agitated extractors for those of high interfacial tension (Treybal, 1980). [Pg.463]

Samples of each batch should be retained in the primary container used for the study or in a suitable bulk container for at least 2 years after the termination or completion of the relevant clinical trial. If the sample is not stored in the pack used for the study, stability data should be available to justify the shelf-life in the pack used. [Pg.112]

Another example is TSK-Phenyl S-PW from Toyo Soda, Japan. To prepare this packing, hydrophobic phenyl groups are attached to TSKgel GSOOOPW, a hydrophilized methacrylate packing used for aqueous size xclusion chromatography (6). [Pg.135]

Finally, you want to make sure that the surface chemistry of the preparative packing is identical to the surface chemistry of the packing used for the loading study. Ask the manufacturer for advice ... [Pg.154]

FIGURE 33.6 Sensor packs used for closed-loop standing. [Pg.535]

Internal dimensions and packings used for acid and oleum towers. [Pg.91]

The column packings used for non-aqueous size-exclusion chromatography fall broadly into three classes ... [Pg.134]

Opening the sample container in many cases the spectrum is collected through the plastic or glass bottle or through the plastic film on food or the plastic bubble packs used for pharmaceutical tablets. In many cases, no sample preparation is required at aU. When DR measurements are made, not only is no sample preparation required, but the method is also nondestructive, as Figure 4.60 shows. [Pg.317]

This Chapter discusses the nature of commercial lithium-ion battery packs used for portable equipment in Section 2, limitations of commercial lithium-ion cells in Section 3, quality control of commercial lithium-ion cells in Section 4 and the commercial li-ion cells and battery pack safety certification process in Section 5. [Pg.388]

NA Steam and flow building Houses hydraulic power packs used for supplying hydraulic control power to steam valves located in the 109-N building. Steel butler-type building. [Pg.109]

Packing used for fractionation can also reduce the pressure drop (Delta P) in a tower compared to trays. Tray designs are more limited in Delta P reduction. The packing surface allows intimate contact between vapor and liquid without having to have the vapor pass through the liquid. The liquid phase coats the packing surface as a film so the liquid phase movement is... [Pg.16]


See other pages where Packing uses for is mentioned: [Pg.337]    [Pg.825]    [Pg.106]    [Pg.388]    [Pg.8]    [Pg.31]    [Pg.226]    [Pg.1756]    [Pg.226]    [Pg.117]    [Pg.70]    [Pg.223]    [Pg.1750]    [Pg.259]    [Pg.287]    [Pg.272]    [Pg.395]    [Pg.1339]    [Pg.569]    [Pg.213]    [Pg.49]    [Pg.12]    [Pg.200]    [Pg.214]   