Packings reversed-phase

Gels made in this way have virtually no usable porosity and are called Jordi solid bead packings. They can be used in the production of low surface area reverse phase packings for fast protein analysis and in the manufacture of hydrodynamic volume columns as well as solid supports for solid-phase syntheses reactions. An example of a hydrodynamic volume column separation is shown in Fig. 13.2 and its calibration plot is shown in Fig. 13.3. The major advantage of this type of column is its ability to resolve very high molecular weight polymer samples successfully. [Pg.369]

Another example of the use of a C8 column for the separation of some benzodiazepines is shown in figure 8. The column used was 25 cm long, 4.6 mm in diameter packed with silica based, C8 reverse phase packing particle size 5 p. The mobile phase consisted of 26.5% v/v of methanol, 16.5%v/v acetonitrile and 57.05v/v of 0.1M ammonium acetate adjusted to a pH of 6.0 with glacial acetic acid and the flow-rate was 2 ml/min. The approximate column efficiency available at the optimum velocity would be about 15,000 theoretical plates. The retention time of the last peak is about 12 minutes giving a retention volume of 24 ml. [Pg.300]

TEST MIXTORES FOR EVALUATING THE PERFORMANCE OF NORMAL AND REVERSED-PHASE PACKINGS... [Pg.698]

It would be easier to describe those classes of compounds not normally separated by RPLC than to catalogue the applications to which RPLC has been turned. Applications for reversed phase can be found in virtually every area of analysis and are reviewed regularly in the journal Analytical Chemistry. RPLC has not been in general use for the analysis of inorganic ions, which are readily separated by ion exchange chromatography polysaccharides, which tend to be too hydrophilic to separate by RPLC polynucleotides, which tend to adsorb irreversibly to the reversed phase packing and compounds which are so hydrophobic that reversed phase offers little selectivity. [Pg.160]

Hanson, M., Kurganov, A., Unger, K. K., and Davankov, V. A., Polymer-coated reversed-phase packings in high-performance liquid chromatography, /. Chromatogr. A, 656, 369, 1993. [Pg.191]

Berger [340] has examined the use of pSFC in polymer/additive analysis. As many polymer additives are moderately polar and nonvolatile SFC is an appropriate separation technique at temperatures well below those at which additives decompose [300,341,342], SFC is also a method of choice for additives which hydrolyse easily. Consequently, Raynor et al. [343] and others [284,344] consider that SFC (especially in combination with SFE) is the method of choice for analysing polymer additives as a relatively fast and efficient sample preparation method. Characterisation of product mixtures of nonpolar to moderately polar components encompassing a wide range of molecular masses can be accomplished by cSFC-FID. Unknown polymer additives may be identified quite adequately by means of cSFC-FID by comparison with retention times of standards [343], However, identification by this method tends to be time-consuming and requires that all the candidate compounds are on hand. SFC-FID of some low-to-medium polarity additives on reversed-phase packed columns... [Pg.214]

J. A. Montgomery, T. P. Johnston, H. J. Thomas, J. R. Piper, and C. Temple, Jr., The use of microparticu-late reversed-phase packing in high pressure liquid chromatography of compounds of biological interest. [Pg.350]

Many other types of solid phase adsorbents, including those based on conventional and specialty materials like restricted access media (RAM), can increase analysis speed and improve assay performance. These types of materials, also known as internal reversed-phase packings, are especially useful for assaying target compounds in biological samples such as serum and plasma. They are chemically modified porous silicas that have hydrophilic external surfaces and restricted-access hydrophobic internal surfaces. The ratio of interior to external surface areas is large. Macromolecules such as proteins cannot enter the pores of the RAM (they are excluded from the hydrophobic internal surface) and they elute quickly through the column. However, the smaller analyte molecules that can enter the pores are retained via interactions with the hydrophobic bonded phase within... [Pg.350]

A mixture of acetyl acetone, 1-nitronaphthalene, and naphthalene has been proposed for evaluating reversed-phase packing material [102]. This reveals the usual optimum kinetic chromatographic parameters (the naphthalene peak), the degree of activity or end-capping status of the column (the ratio of the 1-nitronaphthalene and naphthalene retention times) and trace metal activity (the shape and intensity of the acetylacetone peak). [Pg.544]

Neue, U. D., Serowik, E., Iraneta, P., Alden, B. A. and Walter, T. H., A Universal Procedure for the Assessment of the Reproducibility and the Classification of Silica-Based Reversed-Phase Packings 1. Assessment of the Reproducibility of Reversed-Phase Packings. /. Chromatogr. A, 849 87—100, 1999. [Pg.121]

The CEC phases must be capable of carrying a charge to generate an EOE and appropriate moieties to facilitate the chromatographic processes. Silica-based reversed-phase packing materials have been most widely used in CEC. The use of polymeric and mixed-mode bonded particles has also been reported. Eor the silica-based phases, the carbon chains bonded on the silica surface provide the retention and selectivity for analytes, and the residual silanol groups on the surface of the silica are ionizable and generate the EOF. [Pg.452]

An HPLC method for chlorogenic acids with lactones in six different commercial brands of roasted coffee was developed by Schrader et al. (143). Hydroxycinnamic acid derivatives, including mono- and di-caffeoylquinic acids, corresponding lactones, and feruloylquinic acids were extracted from coffee with methanol at 80°C for 1 h under reflux. An HPLC method using step-gradient elution with 2% aqueous acetic acid (eluent A) and ACN (eluent B) for a 75-min run time was developed. Determination was carried out by HPLC with UV detection at 324 nm, and further confirmation was conducted by HPLC-thermospray (TSP)-MS and HPLC-diode array detection. Elution order for mono-caffeoylquinic acid (CQA) was 3-CQA, 5-CQA, followed by 4-CQA, which was different from the usual elution order of mono-CQA (Fig. 17). These results indicate that it is currently not possible to predict the elution order of different reversed-phase packings due to the different selectivity (143). [Pg.814]


See other pages where Packings reversed-phase is mentioned: [Pg.156]    [Pg.110]    [Pg.121]    [Pg.150]    [Pg.207]    [Pg.189]    [Pg.701]    [Pg.715]    [Pg.109]    [Pg.274]    [Pg.160]    [Pg.140]    [Pg.32]    [Pg.63]    [Pg.309]    [Pg.106]    [Pg.106]    [Pg.107]    [Pg.117]    [Pg.121]    [Pg.453]    [Pg.39]    [Pg.41]    [Pg.240]    [Pg.248]    [Pg.32]    [Pg.76]    [Pg.239]    [Pg.240]    [Pg.480]    [Pg.610]    [Pg.187]    [Pg.17]    [Pg.75]    [Pg.504]   
See also in sourсe #XX -- [ Pg.106 ]

See also in sourсe #XX -- [ Pg.17 , Pg.18 , Pg.19 ]




SEARCH



Internal-surface reversed-phase packings

Packings phase

Reverse-phase packing, description

Reversed-phase HPLC column packings

Reversed-phase columns packings

Reversed-phase packing materials, silica-based

Reversed-phase packings variation