Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

On-line setting

A recent extension of the scope of SPE-GC and SPE-GC-MS concerns the use of AED detection with its multielement detection capability and unusually high selectivity. Hankemeier [67] has described on-line SPE-GC-AED with an on-column interface to transfer 100 iL of desorbing solvent to the GC. The fully on-line set-up is characterised by detection limits of 5-20 ngL because of quantitative transfer of the analytes from the SPE to the GC module. On-line coupling of SPE with GC is more delicate than SPE-LC, because of the inherent incompatibility between the aqueous part of the SPE step and the dry part of the GC system. [Pg.437]

The results for the remaining case studies are summarized in Table 6. An important aspect obtained from these results is that in all cases, the minimum batch time to obtain the desired product concentration in the on-line set point... [Pg.112]

Step 3 Next choose Postprocessing/Domain Plot Parameters/General, and fill in the window. Click on the Line Extrusion tab, and choose concentration to plot (it is the default choice). Click on Line Settings, choose Legend, and set the Line Marker to Cycle. Chck Apply or OK. Figure. 9.7 is the result. [Pg.156]

When Is NIR Imaging Worth Using in On-Line Settings ... [Pg.274]

Among the above-described advantages of NIR hyperspectral imaging in on-line settings, we can include the following ... [Pg.274]

NIR imaging can be used to discriminate between same-color objects with different chemical compositions among the properties of NIR this is the most exploited in on-line settings, to sort objects of diverse composition. [Pg.274]

Blood components are also collected through apheresis. In apheresis, advanced blood cell separators are used to collect one or more specific blood components from a donor. The cell separators collect blood iato a separation chamber, isolate the desired blood components, and return the blood components not needed to the donor. This procedure is performed on-line within one sterile disposable tubiag set. The two principal components collected through apheresis are plasma and siagle-donor platelets (SDP). [Pg.520]

Immunosensors promise to become principal players ia chemical, diagnostic, and environmental analyses by the latter 1990s. Given the practical limits of immunosensors (low ppb or ng/mL to mid-pptr or pg/mL) and their portabiUty, the primary appHcation is expected to be as rapid screening devices ia noncentralized clinical laboratories, ia iatensive care faciUties, and as bedside monitors, ia physicians offices, and ia environmental and iadustrial settings (49—52). Industrial appHcations for immunosensors will also include use as the basis for automated on-line or flow-injection analysis systems to analyze and control pharmaceutical, food, and chemical processing lines (53). Immunosensors are not expected to replace laboratory-based immunoassays, but to open up new appHcations for immunoassay-based technology. [Pg.30]

In 1982, the European Space Agency s Information Retrieval Service (ESA/IRS) introduced the ZOOM command, providing users with a mechanism to analy2e retrieved sets. In 1984, service at a baud rate of 2400 was made available by Tymnet and Telenet for pubHc access to on-line databases. In 1985, the first commercial CD-ROM drives for personal computers became available, along with the first commercial CD-ROM databases. [Pg.113]

Numeric. Researchers routinely use reported numeric measurements and data in thek work. Handbooks have been the primary source for locating this type of information, but numeric databases are now increasing in availabiUty. Advantages of searching numeric databases on-line include ease of use, dkect access to desked data, and abiUty to manipulate the information in the answer set. [Pg.118]

A CIP system includes pipelines, interconnected with valves to direct fluid to appropriate locations, and the control circuit, which consists of interlines to control the valves that direct the cleaning solutions and water through the lines, and air lines which control and move the valves. A programmer controls the timing and the air flow to the valves on a set schedule. The 3A Standards for CIP components, equipment, and installation have been developed. A simple CIP system circuit is shown in Figure 11. [Pg.361]

On-line analysis is often more expensive and difficult to set up initially but can be more accurate and rehable if performed properly. On-line analyzers can also be used to provide real-time control of a process through a secondary variable such as severity or conversion, as opposed to controlling a primary variable, such as temperature (36,52). [Pg.42]

Foxboro developed a self-tuning PID controller that is based on a so-called expert system approach for adjustment of the controller parameters. The on-line tuning of K, Xi, and Xo is based on the closed-loop transient response to a step change in set point. By evaluating the salient characteristics of the response (e.g., the decay ratio, overshoot, and closed-loop period), the controller parameters can be updated without actually finding a new process model. The details of the algorithm, however, are proprietary... [Pg.735]

Membrane extraetion ean easily be set up in flow systems and ean be eonneeted in an automated way on-line to various analytieal instmments. Also, offline eheap hollow-fiber systems are available. High degrees of elean up and enriehment ai e obtained, whieh is very important for reliable and sensitive ehemieal analysis. Reeent applieations of automated detenuination of PCB and phenols will be presented. [Pg.244]

Many plants use off-line optimization. Off-line optimization is an open loop eontrol system. Instead of the elosed loop system, whieh eontrols the plant settings, data is provided to the operator so that he ean make the deeisions based on the findings of the operational data. Off-line systems are also used by engineers to design plants and by maintenanee personnel to plan plant maintenanee. Comparisons of the on-line systems to off-line systems ean be seen in Table 19-1. [Pg.654]

When the reboiler was brought back on line, the water was swept into the heat transfer oil lines and immediately vaporized. This set up a liquid hammer, which burst the surge tank. It was estimated that this required a gauge pressure of 450 psi (30 bar). The top of the vessel was blown off in one piece, and the rest of the vessel was split into 20 pieces. The hot oil formed a cloud of fine mist, which ignited immediately, forming a fireball 35 m in diameter. (Mists can explode at temperatures below the flash point of the bulk liquid see Section 19.5.)... [Pg.258]

The applicability of these findings for actual operational tasks was evaluated by considering the incidence of data entry errors recorded by the on-line plant computer system over the 24-hour shift cycles. It was judged that the data entry task, which involved evaluating the set point changes needed for... [Pg.116]

Figure 2.17 Schematic representation of the set-up used for on-line liquid-liquid exti action coupled with capillary GC when using a membrane phase separator. Reprinted from Journal of High Resdution Chromatography, 13, E. C. Goosens et al., Determination of hexachloro-cyclohexanes in gi ound water by coupled liquid-liquid extraction and capillaiy gas cliro-matography , pp. 438-441, 1990, with permission from Wiley-VCH. Figure 2.17 Schematic representation of the set-up used for on-line liquid-liquid exti action coupled with capillary GC when using a membrane phase separator. Reprinted from Journal of High Resdution Chromatography, 13, E. C. Goosens et al., Determination of hexachloro-cyclohexanes in gi ound water by coupled liquid-liquid extraction and capillaiy gas cliro-matography , pp. 438-441, 1990, with permission from Wiley-VCH.

See other pages where On-line setting is mentioned: [Pg.126]    [Pg.239]    [Pg.126]    [Pg.113]    [Pg.279]    [Pg.519]    [Pg.126]    [Pg.239]    [Pg.126]    [Pg.113]    [Pg.279]    [Pg.519]    [Pg.343]    [Pg.723]    [Pg.329]    [Pg.112]    [Pg.114]    [Pg.200]    [Pg.150]    [Pg.52]    [Pg.54]    [Pg.56]    [Pg.57]    [Pg.354]    [Pg.460]    [Pg.80]    [Pg.534]    [Pg.741]    [Pg.506]    [Pg.654]    [Pg.291]    [Pg.449]    [Pg.450]    [Pg.16]    [Pg.17]    [Pg.31]    [Pg.35]   


SEARCH



When Is NIR Imaging Worth Using in On-Line Settings

© 2024 chempedia.info