Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Numbers of standards

READ STANDARD DEVIATIONS OF VLE MEASUREMENTS- ND IS THE NUMBER OF STANDARD DEVIATIONS WHICH ARE DUPLICATED (1.UE.NO.LE-NN). [Pg.235]

Fig. 2.26 Comparison of a number of standard isotherms of nitrogen at 77 K, plotted as n/n against pip . O, Shnll x, Pierce , de Boer el , Cranston and Inkley. ... Fig. 2.26 Comparison of a number of standard isotherms of nitrogen at 77 K, plotted as n/n against pip . O, Shnll x, Pierce , de Boer el , Cranston and Inkley. ...
The steps may be so chosen as to correspond to consecutive points on the experimental isotherm. In practice it is more convenient to divide the desorption process into a number of standard steps, either of relative pressure, or of pore radius, which is of course a function of relative pressure. The amount given up during each step i must be converted into a liquid volume i , (by use of the normal liquid density) in some procedures the conversion is deferred to a late stage in the calculation, but conceptually it is preferable to undertake the conversion at the outset. As indicated earlier, the task then becomes (i) to calculate the contribution dv due to thinning of the adsorbed film, and thus obtain the core volume associated with the mean core radius r by the subtraction = t ... [Pg.134]

Complex environmental samples originate from diverse matrices (the predominant material of which the sample to be analyzed is composed). These matrices, usually either water or soil/sediment, can contain as many as 50 to 100 organic components at widely varying concentrations. The EPA approach to the analysis of these samples involves the analysis of specific (or target) compounds and the use of authentic standards for quality control. The current number of standards in the EPA repository is about 1500, and their analysis is covered by various approved methods. [Pg.295]

Determined by revised ASTM standard number of standard not yet assigned. [Pg.295]

There are a large number of standard methods suitable for each stage in the hazard analysis and risk assessment procedure. The selection of the proper method depends on several factors. Some of these are the type of process, the stage in the lifetime of the process, the experience and capabiUties of the participants, and the step in the procedure that is being examined. Information regarding the selection of the proper procedure is available in an excellent and comprehensive reference (1). [Pg.470]

Effectiveness of these EP oils can be evaluated by a number of laboratory test units such as those shown in Figure 4. While the American Society for Testing and Materials (ASTM) procedures describe a number of standard test procedures (10), the operating conditions and test specimen materials should be chosen to simulate as nearly as possible those in an appHcation. [Pg.236]

It is necessary to use a sufficient number of standards to adequately define the relationship between concentration and response. [Pg.243]

Calibration Cahbration entails the adjustment of a measurement device so that the value from the measurement device agrees with the value from a standard. The International Standards Organization (ISO) has developed a number of standards specifically directed to cahbration of measurement devices. Furthermore, compliance with the ISO 9000 standards requires that the working standard used to cahbrate a measurement device must be traceable to an internationally recognized standard such as those maintained by the National Institute of Standards and Technology (NIST). [Pg.759]

Performance and Cost Data for Indirect-Heat Rotary Steam-Tube Dryers Table 12-22 contains data for a number of standard sizes of steam-tube diyers. Prices tabulated are for ordinaiy carbon steel construction. Installed costs will run from 150 to 300 percent of purchase cost. [Pg.1210]

A typical low-alloy grade [American Iron and Steel Institute (AISI) 4340] contains 0.40 percent C, 0.70 percent Mn, 1.85 percent Ni, 0.80 percent Cr, and 0.25 percent Mo. Many other alloying agents are used to produce a large number of standard AISI and proprietary grades. [Pg.2443]

A number of standard synthetic reference books are available. A review article by Kossell and Seliger discusses protective groups used in oligonucleotide syntheses, including protection for the phosphate group, which is not included in this book, and a series of articles describe various aspects of protective group chemistry. [Pg.4]

The empirical parameters method uses simple mathematical approximation equations, whose coefficients (empirical parameters) are predetermined from the experimental intensities and known compositions and thicknesses of thin-film standards. A large number of standards are needed for the predetermination of the empirical parameters before actual analysis of an unknown is possible. Because of the difficulty in obtaining properly calibrated thin-film standards with either the same composition or thickness as the unknown, the use of the empirical parameters method for the routine XRF analysis of thin films is very limited. [Pg.342]

SIMS is one of the most powerful surface and microanalytical techniques for materials characterization. It is primarily used in the analysis of semiconductors, as well as for metallurgical, and geological materials. The advent of a growing number of standards for SIMS has gready enhanced the quantitative accuracy and reliability of the technique in these areas. Future development is expected in the area of small spot analysis, implementation of post-sputtering ionization to SIMS (see the articles on SALI and SNMS), and newer areas of application, such as ceramics, polymers, and biological and pharmaceutical materials. [Pg.548]

There are literally many thousands of chemical compounds that are potential air pollutants. It would be impossible to present all the pertinent data and information needed to evaluate each and every air pollution scenario. There are, however, a wealth of information and data bases that are available on the worldwide Web, along with a number of standard hard copy references to obtain information on the chemical and physical properties, and health risks of potential atmospheric contaminants. [Pg.148]

Recently, much emphasis has been put on the harmful effects of small particles, i.e., particulate matter (PM), on human health. A number of standards have been established to characterize the PM fractions in the air and their effects on human health. A widely used PM standard in force in both Europe and the United States is based on the mass concentration of particles with a diameter of 10 gm or less (PMjo). However, recently the U.S. Environmental Protection Agency (EPA) proposed a new standard that is based on the aerodynamic diameter of 2.5 gm particles. This new standard emphasizes the significant impact of small particles on human health, especially on the respiratory and cardiovascular systems. 4 ... [Pg.251]

The requirements governing certification to ISO 9000 are contained in a number of standards ... [Pg.13]

Process workers often complain that valves are inaccessible. Emergency valves should always be readily accessible but other valves, if they are operated, say, once a year or less often, can be out of reach. It is reasonable to expect workers to get a ladder or scramble into a pipe trench at this frequency. Designers should remember that if a valve is just within reach of an average person then half of the population cannot reach it. Equipment should be placed such that at least 95% of the population can reach it. Guidance on specific measurements to achieve this objective is available in a number of standard human factors textbooks (see Bibliography). [Pg.119]

The Gl procedure consists of a number of standard calculation steps that aim to find an equilibrium geometry, an electronic energy and a set of harmonic force constants. The defects mentioned above are assumed additive, and they are investigated in turn. [Pg.322]

A suitable planned maintenance system, irrespective of the location or type of business, is complied from a number of standard elements (see the appendix at the end of this chapter) ... [Pg.785]

A number of standards exist for the determination of some of these parameters. BS 1377 Part 3 1990 refers to methods of tests for soils for civil engineering purposes, and Part 9 refers to these and corrosivity tests in situ. It is significant that the standard draws attention to the fact that the results of the tests that are described should be interpreted by a specialist. ASTM tests for pH and resistivity of soil used for corrosion testing are covered by G51 1977(R1984) and G57 1978 (R1984), respectively. [Pg.1077]

Throughout this book the use of a number of standard analytical samples is recommended in order that practical experience may be gained on substances of known composition. In addition, standard reference materials of environmental samples for trace analysis are used for calibration standards, and pure organic compounds are employed as standard materials for elemental analysis. [Pg.830]

The treatment in this chapter has been theoretical. For a brief, dear, and very practical description of computational details for a number of standard problems, [10] is unsurpassed, and [12] can be recommended for programming techniques for automatic computers. For information on ordinary differential equations, the reader should consult [2], and for partial differential equations, [1]. For general methods of reduction to algebraic form as well as methods of solution, see [5], [7], and [8]. [Pg.97]

Nevertheless, despite all the new resins primarily designed for specialist market niches, for the most part we are primarily concerned with a limited number of standard resin types that provide common exchange functions for general industrial and institutional boiler plant processes such as ... [Pg.346]

Although the decomposition of a data table yields the elution profiles of the individual compounds, a calibration step is still required to transform peak areas into concentrations. Essentially we can follow two approaches. The first one is to start with a decomposition of the peak cluster by one of the techniques described before, followed by the integration of the peak of the analyte. By comparing the peak area with those obtained for a number of standards we obtain the amount. One should realize that the decomposition step is necessary because the interfering compound is unknown. The second approach is to directly calibrate the method by RAFA, RBL or GRAFA or to decompose the three-way table by Parafac. A serious problem with these methods is that the data sets measured for the sample and for the standard solution should be perfectly synchronized. [Pg.303]

Perform a regression analysis on the calibration curve and calculate the values of slope (m), intercept i) and for a number of standards n. [Pg.69]


See other pages where Numbers of standards is mentioned: [Pg.985]    [Pg.546]    [Pg.167]    [Pg.124]    [Pg.548]    [Pg.22]    [Pg.427]    [Pg.354]    [Pg.22]    [Pg.113]    [Pg.11]    [Pg.182]    [Pg.299]    [Pg.501]    [Pg.620]    [Pg.19]    [Pg.486]    [Pg.30]    [Pg.318]    [Pg.796]    [Pg.569]    [Pg.210]    [Pg.1]    [Pg.12]   
See also in sourсe #XX -- [ Pg.276 ]




SEARCH



Minimal Number of Internal Standards for Quantification

Standard Form (Exponential) Numbers and Powers of

Standard number

© 2024 chempedia.info