Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Monitoring design

Frederick, E. R. (ed.), "Proceedings, ConHnuous Emission Monitoring Design, Operation, and Experience, Specialty Conference." Air Pollution Control Association, Pittsburgh, 1981. Morrow, N. L, Brief, R. S., and Bertrand, R. R., Chem. Eng. 79, 85-98 (1972). [Pg.552]

Maintain direct contact with users to monitor design engineering and quality assurance potential problems for newly fielded items Materiel Assignments. [Pg.744]

If the exploratory study Is conducted well. It will provide some data for achieving the overall objectives of the total monitoring study. It will provide a check of the feasibility and efficacy of all aspects of the monitoring design Including the QA/QC plan. It will serve as a training vehicle for participants. It will pinpoint where additional measurements need to be made. Finally, It will provide a body of Information and data which may be Incorporated Into the final report for the total monitoring study. [Pg.104]

Project cost data were reported for 24 of the 138 SVE projects in the dataset. In most cases, the components that make up the project costs were not reported. However, it is likely that these incorporate different components, such as treatment, monitoring, design, oversight, and health and safety. The median reported total cost for all SVE projects was approximately USD206,000, with most projects having a total cost between USD100,000 and USD400,000. [Pg.1010]

Another sensor system that further expands the capabilities of the Chronotox is the Personal Tape Sampler (PTS). The PTS (Figure 5) is a miniaturized gas monitor designed primarily to be worn by a worker during his entire workshift. It operates on the principle of specific chemical colorimetric reactions occurring on a dry chemically impregnated paper tape and gives... [Pg.525]

As another example let us describe an environmental particulate monitor designed for continuously monitoring radioactive contamination of air, as developed by MGP Instruments Inc., 5000 Highlands Parkway, Suite 150, Smyrna, Georgia 30082, tel. (404) 432 2744, fax (404) 432 9179. [Pg.428]

Pry, W.C. Stagner, W.C. Wichman, K.C. Computer-interfaced capacitive sensor for monitoring the granulation process 1 granulation monitor design and application. J. Pharm. Sci. 1984, 73, 420-421. [Pg.4096]

In evaluating the electrode for use with cooling tower waters, Dimmock and Midgley [4 ] concluded that the potentiometric method is at least as sensitive as any other cuTently availaUe, and is che )er and more convenient than otlier methods of comparable sensitivity and precision . We have tried to anticipate field conditions and their impact upon the method, so the information could be incorporated into monitor design. While comparisons may be odious, they are also inevitable, so we included the established techniques in our testing. [Pg.779]

Kollat, J.B., Reed, P.M., 2006. Comparing state-of-the-art evolutionary multi-objective algorithms for long-term groundwater monitoring design. Advances in Water Resources, 29(2006), 792-807. [Pg.544]

Hanrahan, G., Patil, D.G. and Wang, J. (2004) Electrochemical sensors for environmental monitoring design, development and applications, J. Environ. Monit., 6, pp. 657-664. [Pg.151]

Processing/industrial Process monitoring and control, quality control, workplace monitoring, waste stream monitoring In-line/at-line analysis, real time monitoring, designed to be smart sensors... [Pg.556]

Applications in Clinical Analysis An example of the application of a potentiometric enzyme-based biosensor in clinical analysis is an automated monitor designed specifically to analyze blood samples at the bedside of palicnls. The i-STAT Portable Clinical Analyzer, shown in I igure 23-14a. is a handheld device capable of determining a broad range of clinically important analytes such as polas-... [Pg.681]

Monitoring design. In order to meet one or several of the objectives the number... [Pg.307]

Cause of liability of defective product Design fault Fabrication fault Instruction fault Negligence during production monitoring Design fault Fabrication fault Instruction fault Possibly development fault... [Pg.25]

Electrochemical H2S sensors are among the most dependable, stable and reliable type of gas detecting sensors available. However, no sensor can detect gas unless it is used. The only way of being sure that toxic contaminants are not present in dangerous concentrations is to look for them with an atmospheric monitor designed for their detection, and take action at the appropriate concentration. [Pg.81]

Screens on computer monitors can also create work-related cases. Reflections of light sources on the screen can cause eye strain and visual errors. The reflected glare may result from reflections of nearby windows or overhead lighting. A user may adjust the head position that leads to fatigued neck and shoulder muscles or related effects. Some call this fanrily of cumulative disorders VDT (visual display terminal) syndrome or computer vision syndrome. Recent monitor designs reduce such problems through non-glare monitor surfaces. [Pg.291]

Yang, Z.F., Ke, T.H. Wang, C.M. et al. 1995. Theory and practice on monitoring design for exca-vation of shiplock at left of Wuqianxi hydroelectric power station. Journal of Engineering Geology 3(2) 1-11. [Pg.8]


See other pages where Monitoring design is mentioned: [Pg.632]    [Pg.158]    [Pg.1041]    [Pg.66]    [Pg.632]    [Pg.289]    [Pg.632]    [Pg.779]    [Pg.784]    [Pg.847]    [Pg.554]    [Pg.382]    [Pg.21]    [Pg.21]    [Pg.612]    [Pg.510]    [Pg.433]    [Pg.73]    [Pg.14]    [Pg.163]    [Pg.6]    [Pg.578]    [Pg.432]    [Pg.4239]    [Pg.324]    [Pg.27]    [Pg.201]    [Pg.351]   
See also in sourсe #XX -- [ Pg.329 , Pg.330 ]




SEARCH



© 2024 chempedia.info