Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Method matrix-assisted laser desorption

Analytes must be liberated from their associated solvent molecules as well as be ionized to allow mass separation. Several ionization methods enable ion production from the condensed phase and have been used for the coupling of CE to MS. Among them, atmospheric pressure ionization (API) methods, matrix-assisted laser desorption/ionization (MALDI), and inductively coupled plasma (ICP) ionization are mainly used. API techniques are undoubtedly the most widespread ionization sources and cover different analyte polarity ranges. [Pg.481]

The fifth category of ionization includes the laser ionization mass spectrometry (LIMS) methods. Matrix-assisted laser desorption ionization (MALDI) uses... [Pg.713]

Thermogravimetric analysis Differential thermal analysis Differential scanning calorimetry Thermal volatiUszation analysis Evolved gas analysis Mass spectroscopy methods Matrix-assisted laser desorption/ionization Imaging chemiluminescence... [Pg.154]

A connnon feature of all mass spectrometers is the need to generate ions. Over the years a variety of ion sources have been developed. The physical chemistry and chemical physics communities have generally worked on gaseous and/or relatively volatile samples and thus have relied extensively on the two traditional ionization methods, electron ionization (El) and photoionization (PI). Other ionization sources, developed principally for analytical work, have recently started to be used in physical chemistry research. These include fast-atom bombardment (FAB), matrix-assisted laser desorption ionization (MALDI) and electrospray ionization (ES). [Pg.1329]

FigureBl.7.2. Schematic representations of alternative ionization methods to El and PI (a) fast-atom bombardment in which a beam of keV atoms desorbs solute from a matrix (b) matrix-assisted laser desorption ionization and (c) electrospray ionization. FigureBl.7.2. Schematic representations of alternative ionization methods to El and PI (a) fast-atom bombardment in which a beam of keV atoms desorbs solute from a matrix (b) matrix-assisted laser desorption ionization and (c) electrospray ionization.
Some solid materials are very intractable to analysis by standard methods and cannot be easily vaporized or dissolved in common solvents. Glass, bone, dried paint, and archaeological samples are common examples. These materials would now be examined by laser ablation, a technique that produces an aerosol of particulate matter. The laser can be used in its defocused mode for surface profiling or in its focused mode for depth profiling. Interestingly, lasers can be used to vaporize even thermally labile materials through use of the matrix-assisted laser desorption ionization (MALDI) method variant. [Pg.280]

The ablated vapors constitute an aerosol that can be examined using a secondary ionization source. Thus, passing the aerosol into a plasma torch provides an excellent means of ionization, and by such methods isotope patterns or ratios are readily measurable from otherwise intractable materials such as bone or ceramics. If the sample examined is dissolved as a solid solution in a matrix, the rapid expansion of the matrix, often an organic acid, covolatilizes the entrained sample. Proton transfer from the matrix occurs to give protonated molecular ions of the sample. Normally thermally unstable, polar biomolecules such as proteins give good yields of protonated ions. This is the basis of matrix-assisted laser desorption ionization (MALDI). [Pg.399]

Matrix-assisted laser desorption/ionization (MALDI) is widely used for the detection of organic molecules. One of the limitations of the method is a strong matrix background in low-mass (up to 500-700 Da) range. In present work an alternative approach based on the application of rough matrix-less surfaces and known as surface-assisted laser desoi ption/ionization (SALDI), has been applied. [Pg.140]

Most biochemical analyses by MS use either electrospray ionization (ESI) or matrix-assisted laser desorption ionization (MALD1), typically linked to a time-of-flight (TOF) mass analyzer. Both ESI and MALDl are "soft" ionization methods that produce charged molecules with little fragmentation, even with biological samples of very high molecular weight. [Pg.417]

MALDI (Section 12.4) Matrix-assisted laser desorption ionization a mild method for ionizing a molecule so that fragmentation is minimized during mass spectrometry. [Pg.1245]

Matrix-assisted laser desorption mass spectrometry (MALDI-MS) is, after electrospray ionization (ESI), the second most commonly used method for ionization of biomolecules in mass spectrometry. Samples are mixed with a UV-absorbing matrix substance and are air-dried on a metal target. Ionization and desorption of intact molecular ions are performed using a UV laser pulse. [Pg.748]

Tandem mass spectrometry (MS/MS) is a method for obtaining sequence and structural information by measurement of the mass-to-charge ratios of ionized molecules before and after dissociation reactions within a mass spectrometer which consists essentially of two mass spectrometers in tandem. In the first step, precursor ions are selected for further fragmentation by energy impact and interaction with a collision gas. The generated product ions can be analyzed by a second scan step. MS/MS measurements of peptides can be performed using electrospray or matrix-assisted laser desorption/ionization in combination with triple quadruple, ion trap, quadrupole-TOF (time-of-flight), TOF-TOF or ion cyclotron resonance MS. Tandem... [Pg.1191]

Two relatively new techniques, matrix assisted laser desorption ionization-lime of flight mass spectrometry (MALDI-TOF) and electrospray ionization (FS1), offer new possibilities for analysis of polymers with molecular weights in the tens of thousands. PS molecular weights as high as 1.5 million have been determined by MALDI-TOF. Recent reviews on the application of these techniques to synthetic polymers include those by Ilantoif54 and Nielen.555 The methods have been much used to provide evidence for initiation and termination mechanisms in various forms of living and controlled radical polymerization.550 Some examples of the application of MALDI-TOF and ESI in end group determination are provided in Table 3.12. The table is not intended to be a comprehensive survey. [Pg.143]

Matrix-assisted laser desorption ionization (MALDI) A method used for the ionization of high-molecular-weight compounds. In this approach, the analyte is crystallized with a solid matrix and then bombarded with a laser of a frequency which is absorbed by the matrix material. [Pg.307]

For non-volatile sample molecules, other ionisation methods must be used, namely desorption/ionisation (DI) and nebulisation ionisation methods. In DI, the unifying aspect is the rapid addition of energy into a condensed-phase sample, with subsequent generation and release of ions into the mass analyser. In El and Cl, the processes of volatilisation and ionisation are distinct and separable in DI, they are intimately associated. In nebulisation ionisation, such as ESP or TSP, an aerosol spray is used at some stage to separate sample molecules and/or ions from the solvent liquid that carries them into the source of the mass spectrometer. Less volatile but thermally stable compounds can be thermally vaporised in the direct inlet probe (DIP) situated close to the ionising molecular beam. This DIP is standard equipment on most instruments an El spectrum results. Techniques that extend the utility of mass spectrometry to the least volatile and more labile organic molecules include FD, EHD, surface ionisation (SIMS, FAB) and matrix-assisted laser desorption (MALD) as the last... [Pg.359]

As evident from Scheme 7.13, most modern ionisation techniques have been used for TLC-MS, and no single ionisation method is used exclusively with TLC-MS. Various ionisation methods may be applied that avoid the need to evaporate the sample into an El or Cl source these are based in particular on sputtering (FAB, SIMS) or laser desorption. Several sputtering methods of ionisation do not require the use of a liquid matrix, e.g. TLC-SIMS [797], Recent developments include the use of matrix-assisted laser desorption ionisation (MALDI) and surface-assisted laser desorption ionisation (SALDI). It is obvious that TLC-MS is complemented with TLC-MS11 [800] and TLC-HRMS techniques. Table 7.82 lists the general characteristics of TLC-MS. [Pg.539]

Meyer-Dulheuer [55] has analysed the pure additives (phenolic antioxidants, benzotriazole UV stabilisers and HALS compounds) of Table 9.8 in THF solutions by means of MALDI-ToFMS. As it turns out, polar molecules in the mass range of below 800 Da, which have a high absorption coefficient at the laser wavelength used, can often be measured without any matrix [55,56]. In this case, there is no matrix-assisted laser desorption and ionisation (MALDI) process any more. It is a simple laser desorption/ionisation (LDI) process. The advantage of this method is a matrix-free mass spectrum with the same mass resolution as in the MALDI case,... [Pg.703]

The focus of this chapter is the development of a technique often called wholecell matrix-assisted laser desorption ionization (MALDI) time-of-flight (TOF) mass spectrometry (MS) or whole-cell MALDI-TOF MS. Some groups prefer to use terms such as intact or unprocessed rather than whole, but the intended meaning is the same regardless of which word is used. As noted in the first chapter of this book, there are many different methods for the analysis of bacteria. However, for the analysis of intact or unprocessed bacteria, whole-cell MALDI-TOF MS is the most commonly used approach. This method is very rapid. MALDI-TOF MS analysis of whole cells takes only minutes because the samples can be analyzed directly after collection from a bacterial culture suspension. Direct MALDI MS analysis of fungi or viruses is similar in approach1,2 but is not covered in this chapter. MALDI-TOF MS of whole cells was developed with very rapid identification or differentiation of bacteria in mind. The name (whole cell) should not be taken to imply that the cells are literally intact or whole. Rather, it should be taken to mean that the cells that have not been treated or processed in any way specifically for the removal or isolation of any cellular components from any others. In whole-cell analysis the cells have been manipulated only as necessary to... [Pg.125]

Jebanathirajah, J. A. Andersen, S. Blagoev, B. Roepstorff, P. A rapid screening method to monitor expression of recombinant proteins from various prokaryotic and eukaryotic expression systems using matrix-assisted laser desorption ioniza-tion-time-of-flight mass spectrometry. Anal. Biochem. 2002, 305, 242-250. [Pg.151]

Bright, J. J. Claydon, M. A. Soufian, M. Gordon, D. B. Rapid typing of bacteria using matrix-assisted laser desorption ionisation time-of-flight mass spectrometry and pattern recognition software. J. Microbiol. Methods 2002, 48, 127-138. [Pg.297]

It is therefore not surprising that the interest in PyMS as a typing tool diminished at the turn of the twenty-first century and hence why taxonomists have turned to MS-based methods that use soft ionization methods such as electrospray ionization (ESI-MS) and matrix-assisted laser desorption ionization (MALDI MS). These methods generate information-rich spectra of metabolites and proteins, and because the molecular ion is seen, the potential for biomarker discovery is being realized. The analyses of ESI-MS and MALDI-MS data will still need chemometric methods, and it is hoped that researchers in these areas can look back and learn from the many PyMS studies where machine learning was absolutely necessary to turn the complex pyrolysis MS data into knowledge of bacterial identities. [Pg.334]

Experimental considerations Sample preparation and data evaluation are similar to membrane osmometry. Since there is no lower cut-off as in membrane osmometry, the method is very sensitive to low molar mass impurities like residual solvent and monomers. As a consequence, the method is more suitable for oligomers and short polymers with molar masses up to (M)n 50kg/mol. Today, vapour pressure osmometry faces strong competition from mass spectrometry techniques such as matrix-assisted laser desorption ionisation mass spectrometry (MALDI-MS) [20,21]. Nevertheless, vapour pressure osmometry still has advantages in cases where fragmentation issues or molar mass-dependent desorption and ionization probabilities come into play. [Pg.217]

The most discriminating technique for proving the identity and purity of analyte peak of a chromatogram, especially for analyzing biological samples and natural products, is by using online LC-UV/MS or GC-MS/FTIR methods [15]. Alternatively, one could use a combination of TLC and MS, where direct determination on the TLC plates is made by matrix-assisted laser desorption ionization mass spectrometry (MALDI MS) [16]. [Pg.247]

Many diseases are characterized by the expression of specific proteins1 in some cases, malignant cells yield unique protein profiles when total cellular protein extracts are analyzed by proteomic methods such as two-dimensional gel electrophoresis or matrix-assisted laser desorption ionization-mass spectrometry (MALDI-MS).2 High-throughput proteomic studies may be useful to differentiate normal cells from cancer cells, to identify and define the use of biomarkers for specific cancers, and to characterize the clinical course of disease. Proteomics can also be used to isolate and characterize potential drug targets and to evaluate the efficacy of treatments. [Pg.235]


See other pages where Method matrix-assisted laser desorption is mentioned: [Pg.754]    [Pg.92]    [Pg.378]    [Pg.88]    [Pg.88]    [Pg.754]    [Pg.92]    [Pg.378]    [Pg.88]    [Pg.88]    [Pg.1331]    [Pg.9]    [Pg.490]    [Pg.6]    [Pg.29]    [Pg.416]    [Pg.468]    [Pg.113]    [Pg.381]    [Pg.12]    [Pg.40]    [Pg.47]    [Pg.162]    [Pg.182]    [Pg.204]    [Pg.230]    [Pg.261]    [Pg.173]    [Pg.738]    [Pg.70]    [Pg.336]   


SEARCH



Assisted Laser Desorption

Laser assisted

Laser desorption

Matrix assisted

Matrix assisted laser method

Matrix-assisted laser

Matrix-assisted laser-desorption

© 2024 chempedia.info