Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Mechanical changes, monitoring

This procedure is essential for the continual operation of the system, process, or equipment and provides a formal mechanism for monitoring changes during the continued operation of the system. Proposed changes that could affect the validated status of a system are reviewed by the validation team or responsible personnel and the proposed corrective action is approved. [Pg.645]

Laser flash photolysis time-resolved spectrophotometry, utilizing deazariboflavin-EDTA as a photochemical reductant, has been used with this system in order to characterize the initial step in the ET mechanism. Figure 3 shows examples of the type of data obtained in these studies. In the top panel, a transient is shown [54] that was obtained at 507 nm in 100 mM phosphate buffer, pH 7.0, containing 35 pM Fd, and in the middle panel, 10.3 pM FNR has been added to the solution prior to photolysis. This wavelength corresponds to an isosbestic point for the FAD cofactor of the reductase, and thus the absorbance change monitors the oxidation state of the [2Fe-2S] cluster of Fd (and also the formation and decay of the dRfH species). As is evident, immediately after the laser flash there is a rapid rise in absorbance due to dRfH formation. This is followed by a sharp absorbance decrease corresponding to Fd reduction and dRfH oxidation. The subsequent slow increase in absorption shown in the middle panel is a consequence of Fd reoxidation that is due to electron transfer to FNR. The latter is confirmed by measurement at 610 nm (bottom panel), a wavelength which monitors FAD neutral semiquinone formation the rate constant obtained from the 610 nm absorbance rise is the same as that obtained from the slow absorbance increase at 507 nm, consistent with this interpretation. [Pg.2586]

Equipment change control— A mechanism to monitor change to previously qualified and/or validated equipment to ensure that planned or unplanned repairs and modifica-... [Pg.210]

Mental effort is also involved if participants perform tasks in adverse conditions. Under these conditions the other aspect of mental effort (compensatory effort) becomes important. In this respect Broadbenfs two arousal mechanisms are relevant (Broadbenf 1971) a lower mechanism concerned with well established (automatic) processes, which is affected by noise and sleeplessness, and an upper mechanism, which monitors and alters the parameters of the lower mechanism. Inefficiency of the lower mechanism will not become manifest in performance provided that the upper mechanism remains efficient. In that case, performance is hardly affected by stress, but has become less efficient because it can only be achieved at higher costs. We (G. Mulder, 1986) hypothesized that this aspect of effort would mainly manifest itself in another set of psychophysiological indices, that is, in changes in muscular activity (e.g., forearm flexor EMG), beta-adrenergic changes in cardiovascular parameters, and increased levels of adrenaline. [Pg.142]

One of the critical problems facing designers of adaptive systems centers around the mechanisms for monitoring changes in workload and switching... [Pg.241]

There are several other thermal analysis techniques. In thermomechanical analysis (TMA), mechanical changes are monitored versus temperature. Expansion and penetration characteristics or stress-strain behavior can be studied. In dynamic mechanical analysis (DMA), the variations with temperature of various moduli are determined, and this information is further used to obtain fundamental information such as transition temperatures. In thermogravimefric analysis (TGA), weight changes as a function of temperature or time (at some elevated temperature) are followed. This information is used to assess thermal stability and decomposition behavior. [Pg.22]

Park DW, Ye SH, Jiang HB, Dutta D, Nonaka K, Wagner WR, et al. In vivo monitoring of structural and mechanical changes of tissue scaffolds by multi-modality imaging. Biomaterials September 2014 35(27) 7851-9. [Pg.109]

The reviews made by F. L. LaQue on this subject indicate that the salt spray test cannot realistically be used, for example, for parts with complicated shapes. This deficiency is principally due to the fact that the salt spray particles fall in vertical patterns, creating a strong orientation dependency. Another major inadequacy of the test is the variable sensitivity of different metallic materials to the ions present in various service environments. Since different metals also are affected differently by changes in the concentrations of salt solutions, the salt spray test is not really appropriate for ranking different materials in an order of relative resistance to salt water or salt air. The variability of the environments, even for seagoing equipment, is another factor that is extremely difficult to reproduce in a laboratory. Before attempting to simulate such natural environments, it is thus recommended that the chemistry of the environment and all other parameters controlling the corrosion mechanisms be monitored over time, in a serious attempt to characterize the worst exposure conditions. [Pg.555]

The amount of a particular component in a sample can be monitored by examining the height of a spectral absorption peak The reduction of an aldehyde to an alcohol would show up as a decrease in line intensity for the carbonyl and an increase for the hydroxyl peaks in the spectrum. Changes in the relative importance of different relaxation modes in a polymer can also be followed by the corresponding changes in a mechanical spectrum. [Pg.183]

Many of the variations developed to make pressure sensors and accelerometers for a wide variety of appHcations have been reviewed (5). These sensors can be made in very large batches using photoHthographic techniques that keep unit manufacturing costs low and ensure part-to-part uniformity. A pressure differential across these thin diaphragms causes mechanical deformation that can be monitored in several ways piezoresistors implanted on the diaphragm are one way changes in electrical capacitance are another. [Pg.390]


See other pages where Mechanical changes, monitoring is mentioned: [Pg.610]    [Pg.274]    [Pg.661]    [Pg.92]    [Pg.338]    [Pg.161]    [Pg.2330]    [Pg.55]    [Pg.225]    [Pg.67]    [Pg.21]    [Pg.69]    [Pg.157]    [Pg.241]    [Pg.218]    [Pg.169]    [Pg.83]    [Pg.160]    [Pg.44]    [Pg.29]    [Pg.29]    [Pg.83]    [Pg.51]    [Pg.333]    [Pg.329]    [Pg.123]    [Pg.200]    [Pg.257]    [Pg.547]    [Pg.301]    [Pg.425]    [Pg.152]    [Pg.511]    [Pg.392]    [Pg.148]    [Pg.43]    [Pg.886]    [Pg.135]    [Pg.192]   
See also in sourсe #XX -- [ Pg.29 ]




SEARCH



Monitoring Changes

© 2024 chempedia.info