Mass spectrometry examples

The types of tandem mass spectrometers capable of performing MS/MS experiments fall into two basic categories tandem in space and tandem in time. Tandem-in-space instruments have discrete mass analyzers for each stage of mass spectrometry examples include multisector, triple-quadru-pole, and hybrid instruments (instruments having mixed types of analyzers such as a magnetic sector and a quadrupole). Tandem-in-time instruments have only one mass analyzer where each stage of mass spectrometry takes place in the same analyzer but is separated in time via a sequence of events. Examples of this type of instrument include Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometers and quadrupole ion traps, described in Chapter 3. [Pg.92]

The technique involves the use of an inductively coupled plasma to convert trace elements to their gaseous ions followed by analysis of these ions by mass spectrometry. Examples include the quantitative analysis of trace copper by isotope dilution and the analysis of trace contaminants in boron, indium phosphide and reagent acids. [Pg.284]

The most important characteristic of electrospray is that in fact it does not generate any new ions. The ions which reach the mass spectrometer were already in solution in one form or another in the chromatographic column. Electrospray helps transfer these solution ions into the gas phase, so that they can be analyzed by mass spectrometry. Examples of ions which can be analyzed by... [Pg.164]

Scope of Mass Spectrometry—Examples of Applications Field Process... [Pg.33]

Mass spectrometry allows analysis by hydrocarbon family for a variety of petroleum cuts as deep as vacuum distillates since we have seen that the molecules must be vaporized. The study of vacuum residues can be conducted by a method of direct introduction which we will address only briefly because the quantitative aspects are ek r metiy difficult to master. Table 3.6 gives some examples the matrices used differ according to the distillation cut and the chemical content such as the presence or absence of olefins or sulfur. [Pg.50]

Mass Spectrometry Aldehydes and ketones typically give a prominent molecular ion peak m their mass spectra Aldehydes also exhibit an M— 1 peak A major fragmentation pathway for both aldehydes and ketones leads to formation of acyl cations (acylium ions) by cleavage of an alkyl group from the carbonyl The most intense peak m the mass spectrum of diethyl ketone for example is m z 57 corresponding to loss of ethyl radi cal from the molecular ion... [Pg.741]

Mass Spectrometry A peak for the molecular ion is usually quite prominent m the mass spectra of phenols It is for example the most intense peak m phenol... [Pg.1015]

In this discussion, only inert gases such as argon or neon are used as examples because they are monatomic, which simplifies description of the excitation. The introduction of larger molecules into a discharge is discussed in later chapters concerning examination of samples by mass spectrometry. [Pg.30]

Another type of ion is formed almost uniquely by the electrospray inlet/ion source which makes this technique so valuable for examining substances such as proteins that have large relative molecular mass. Measurement of m/z ratios usually gives a direct measure of mass for most mass spectrometry because z = 1 and so m/z = m/1 = m. Values of z greater than one are unusual. However, for electrospray, values of z greater than one (often much greater), are quite coimnonplace. For example, instead of the [M + H]+ ions common in simple Cl, ions in electrospray can be [M + n-H]- where n can be anything from 1 to about 30. [Pg.57]

The nebulization concept has been known for many years and is commonly used in hair and paint spays and similar devices. Greater control is needed to introduce a sample to an ICP instrument. For example, if the highest sensitivities of detection are to be maintained, most of the sample solution should enter the flame and not be lost beforehand. The range of droplet sizes should be as small as possible, preferably on the order of a few micrometers in diameter. Large droplets contain a lot of solvent that, if evaporated inside the plasma itself, leads to instability in the flame, with concomitant variations in instrument sensitivity. Sometimes the flame can even be snuffed out by the amount of solvent present because of interference with the basic mechanism of flame propagation. For these reasons, nebulizers for use in ICP mass spectrometry usually combine a means of desolvating the initial spray of droplets so that they shrink to a smaller, more uniform size or sometimes even into small particles of solid matter (particulates). [Pg.106]

Aerosols can be produced as a spray of droplets by various means. A good example of a nebulizer is the common household hair spray, which produces fine droplets of a solution of hair lacquer by using a gas to blow the lacquer solution through a fine nozzle so that it emerges as a spray of small droplets. In use, the droplets strike the hair and settle, and the solvent evaporates to leave behind the nonvolatile lacquer. For mass spectrometry, a spray of a solution of analyte can be produced similarly or by a wide variety of other methods, many of which are discussed here. Chapters 8 ( Electrospray Ionization ) and 11 ( Thermospray and Plasmaspray Interfaces ) also contain details of droplet evaporation and formation of ions that are relevant to the discussion in this chapter. Aerosols are also produced by laser ablation for more information on this topic, see Chapters 17 and 18. [Pg.138]

Recently, it has become possible to create isotopes that do not exist naturally. These are the artificial isotopes, and all are radioactive. For example, 13 artificially created isotopes of iodine are known, as well as its naturally occurring monoisotopic form of mass 127. Mass spectrometry is able to measure m/z values for both natural and artificial isotopes. [Pg.339]

This example can be used in reverse to show the usefulness of looking for such isotopes. Suppose there were an unknown sample that had two molecular ion peaks in the ratio of 3 1 that were two mass units apart then it could reasonably be deduced that it was highly likely the unknown contained chlorine. In this case, the isotope ratio has been used to identify a chlorine-containing compound. This use of mass spectrometry is widespread in general analysis of materials, and it... [Pg.339]

A common mistake for beginners in mass spectrometry is to confuse average atomic mass and isotopic mass. For example, the average atomic mass for chlorine is close to 35.45, but this average is of the numbers and masses of Cl and Cl isotopes. This average must be used for instruments that cannot differentiate isotopes (for example, gravimetric balances). Mass spectrometers do differentiate isotopes by mass, so it is important in mass spectrometry that isotopic masses be used... [Pg.348]

Few of the naturally occurring elements have significant amounts of radioactive isotopes, but there are many artificially produced radioactive species. Mass spectrometry can measure both radioactive and nonradioactive isotope ratios, but there are health and safety issues for the radioactive ones. However, modem isotope instmments are becoming so sensitive that only very small amounts of sample are needed. Where radioactive isotopes are a serious issue, the radioactive hazards can be minimized by using special inlet systems and ion pumps in place of rotary pumps for maintaining a vacuum. For example, mass spectrometry is now used in the analysis of Pu/ Pu ratios. [Pg.354]

Thus, either the emitted light or the ions formed can be used to examine samples. For example, the mass spectrometric ionization technique of atmospheric-pressure chemical ionization (APCI) utilizes a corona discharge to enhance the number of ions formed. Carbon arc discharges have been used to generate ions of otherwise analytically intractable inorganic substances, with the ions being examined by mass spectrometry. [Pg.388]

In mass spectrometry, the required connectivities (links) can be obtained from observations on metastable ions. For example, finding a metastable ion for a supposed process, M+ F3+, proves the process exists. [Pg.412]

Routine mass spectrometry can be used to identify many elements from their approximate ratios of isotope abundances. For example, mercury-containing compounds give ions having the seven isotopes in an approximate ratio of 0.2 10.1 17.0 23.1 13.2 29.7 6.8. [Pg.425]

Multidimensional or hyphenated instmments employ two or more analytical instmmental techniques, either sequentially, or in parallel. Hence, one can have multidimensional separations, eg, hplc/gc, identifications, ms/ms, or separations/identifications, such as gc/ms (see CHROMATOGRAPHY Mass spectrometry). The purpose of interfacing two or more analytical instmments is to increase the analytical information while reducing data acquisition time. For example, in tandem-mass spectrometry (ms/ms) (17,18), the first mass spectrometer appHes soft ionization to separate the mixture of choice into molecular ions the second mass spectrometer obtains the mass spectmm of each ion. [Pg.394]

Because of the complexity of the polyether antibiotics tittle progress has been made in stmcture determination by the chemical degradation route. X-ray methods were the techniques most successfully applied for the early stmcture elucidations. Monensin, X206, lasalocid, lysocellin, and salinomycin were included in nineteen distinct polyether x-ray analyses reported in 1983 (190). Use of mass spectrometry (191), and H (192) and nmr (141) are also reviewed. More recently, innovative developments in these latter techniques have resulted in increased applications for stmcture determinations. Eor example, heteronuclear multiple bond connectivity (hmbc) and homonuclear Hartmann-Hahn spectroscopy were used to solve the stmcture of portimicin (14) (193). East atom bombardment mass spectrometry was used in solving the stmctures of maduramicin alpha and co-factors (58). [Pg.172]

Laser based mass spectrometric methods, such as laser ionization (LIMS) and laser ablation in combination with inductively coupled plasma mass spectrometry (LA-ICP-MS) are powerful analytical techniques for survey analysis of solid substances. To realize the analytical performances methods for the direct trace analysis of synthetic and natural crystals modification of a traditional analytical technique was necessary and suitable standard reference materials (SRM) were required. Recent developments allowed extending the range of analytical applications of LIMS and LA-ICP-MS will be presented and discussed. For example ... [Pg.425]

In looking for the mechanism, many intermediates are assumed. Some of these are stable molecules in pure form but very active in reacting systems. Other intermediates are in very low concentration and can be identified only by special analytical methods, like mass spectrometry (the atomic species of hydrogen and halogens, for example). These are at times referred to as active centers. Others are in transition states that the reacting cheimicals form with atoms or radicals these rarely can be isolated. In heterogeneous catalytic reaction, the absorbed reactant can... [Pg.115]

Sputtered Neutral Mass Spectrometry (SNMS) is the mass spectrometric analysis of sputtered atoms ejected from a solid surface by energetic ion bombardment. The sputtered atoms are ionized for mass spectrometric analysis by a mechanism separate from the sputtering atomization. As such, SNMS is complementary to Secondary Ion Mass Spectrometry (SIMS), which is the mass spectrometric analysis of sputtered ions, as distinct from sputtered atoms. The forte of SNMS analysis, compared to SIMS, is the accurate measurement of concentration depth profiles through chemically complex thin-film structures, including interfaces, with excellent depth resolution and to trace concentration levels. Genetically both SALI and GDMS are specific examples of SNMS. In this article we concentrate on post ionization only by electron impact. [Pg.43]

This article discusses why one would choose nonresonant multiphoton ionization for mass spectrometry of solid surfaces. Examples are given for depth profiling by this method along with thermal desorption studies. [Pg.569]


See other pages where Mass spectrometry examples is mentioned: [Pg.162]    [Pg.104]    [Pg.162]    [Pg.104]    [Pg.814]    [Pg.1851]    [Pg.2390]    [Pg.55]    [Pg.8]    [Pg.61]    [Pg.195]    [Pg.226]    [Pg.245]    [Pg.269]    [Pg.277]    [Pg.277]    [Pg.277]    [Pg.314]    [Pg.337]    [Pg.343]    [Pg.478]    [Pg.212]    [Pg.509]    [Pg.540]    [Pg.548]    [Pg.214]    [Pg.21]    [Pg.189]   