Mass spectrometry ionisation techniques

Although not fully exploited because of the high diversity and complexity of laser experiments the introduction of multiphoton ionisation into mass spectrometry significantly expanded the applicability of this tool in the analysis of complex gas mixtures as the polluted atmosphere. Molecular specificity as obtained in high resolution vibrational spectroscopy combined with high sensitivity as known for ion counting methods makes this new technique unique in untangling reaction mechanisms [15, 19,20,24]. [Pg.211]

Cox and co-workers [179] analysed PS/polyvinyl methyl ether blends by coincidence counting ToF mass spectrometry. This technique gave information on the chemical and spatial relationships between secondary ions. Thompson [180] carried out a quantitative surface analysis of organic polymer blends (e.g., miscible polycarbonate/PS blends) using ToF-SIMS. Lin and co-workers [181] used supersonic beam/multiphoton ionisation/ToF mass spectrometry to analyse photoablation products resulting from styrene-containing polymers snch as styrene-bntadiene, ABS, and PS foams. Photoablation products were examined by snpersonic beam spectrometry and the results were compared with those obtained by thermal decomposition. [Pg.128]

The structures of three bacillomycins D, F and L have been completely established as (59), (58) and (60) respectively. All of them contained the characteristic iturinic acids and seven a-amino acids. The sequence of amino acids was studied using chemical methods, in particular Edman degradation of the product obtained by specific cleavage of the peptide moiety with N-bromosuccinimide. Confirmatory results were obtained by chemical ionisation (isobutane) mass spectrometry and various techniques of NMR spectroscopy. The exact molecular weights of the various species were obtained by FAB mass spectrometry 146, 147) (see Table 7). [Pg.51]

Spectroscopy Chemical Ionisation in Mass Spectrometry Chromatography-MS, Methods Hyphenated Techniques, Applications of in Mass Spectrometry Inductively Coupled Plasma Mass Spectrometry, Methods Mass Spectrometry, Historical Perspective MS-MS and MS" Photoacoustic Spectroscopy, Applications. [Pg.766]

Tandem mass spectrometry or ms/ms was first introduced in the 1970s and gained rapid acceptance in the analytical community. The technique has been used for stmcture elucidation of unknowns (26) and has the abiUty to provide sensitive and selective analysis of complex mixtures with minimal sample clean-up (27). Developments in the mid-1980s advancing the popularity of ms/ms included the availabiUty of powerhil data systems capable of controlling the ms/ms experiment and the viabiUty of soft ionisation techniques which essentially yield only molecular ion species. [Pg.405]

In addition to the wet and optical spectrometric methods, which are often used to analyse elements present in very small proportions, there are also other techniques which can only be mentioned here. One is the method of mass spectrometry, in which the proportions of separate isotopes can be measured this can be linked to an instrument called a field-ion microscope, in which as we have seen individual atoms can be observed on a very sharp hemispherical needle tip through the mechanical action of a very intense electric field. Atoms which have been ionised and detached can then be analysed for isotopic mass. This has become a powerful device for both curiosity-driven and applied research. [Pg.234]

In this chapter, we have chosen from the scientific literature accounts of symposia published at intervals during the period 1920 1990. They are personal choices illustrating what we believe reflect significant developments in experimental techniques and concepts during this time. Initially there was a dependence on gas-phase pressure measurements and the construction of adsorption isotherms, followed by the development of mass spectrometry for gas analysis, surface spectroscopies with infrared spectroscopy dominant, but soon to be followed by Auger and photoelectron spectroscopy, field emission, field ionisation and diffraction methods. [Pg.9]

Principles and Characteristics Ionisation processes are the basis for mass-spectrometric detection. Each of the ionisation techniques occupies its own position in mass spectrometry. The optimum performance of any ionisation method (and therefore the result) will depend critically on the characteristics and reliability of the mass spectrometer. Ionisation may occur in the gas, liquid or condensed phase, and may be either hard or soft , i.e. with or without extensive... [Pg.357]

For non-volatile sample molecules, other ionisation methods must be used, namely desorption/ionisation (DI) and nebulisation ionisation methods. In DI, the unifying aspect is the rapid addition of energy into a condensed-phase sample, with subsequent generation and release of ions into the mass analyser. In El and Cl, the processes of volatilisation and ionisation are distinct and separable in DI, they are intimately associated. In nebulisation ionisation, such as ESP or TSP, an aerosol spray is used at some stage to separate sample molecules and/or ions from the solvent liquid that carries them into the source of the mass spectrometer. Less volatile but thermally stable compounds can be thermally vaporised in the direct inlet probe (DIP) situated close to the ionising molecular beam. This DIP is standard equipment on most instruments an El spectrum results. Techniques that extend the utility of mass spectrometry to the least volatile and more labile organic molecules include FD, EHD, surface ionisation (SIMS, FAB) and matrix-assisted laser desorption (MALD) as the last... [Pg.359]

Applications Early MS work on the analysis of polymer additives has focused on the use of El, Cl, and GC-MS. The major drawback to these methods is that they are limited to thermally stable and relatively volatile compounds and therefore are not suitable for many high-MW polymer additives. This problem has largely been overcome by the development of soft ionisation techniques, such as FAB, FD, LD, etc. and secondary-ion mass spectrometry. These techniques all have shown their potential in the analysis of additives from solvent extract and/or from bulk polymeric material. Although FAB has a reputation of being the most often used soft ionisation method, Johlman el al. [83] have shown that LD is superior to FAB in the analysis of polymer additives, mainly because polymer additives fragment extensively under FAB conditions. [Pg.370]

Recently, Lattimer et al. [22,95] advocated the use of mass spectrometry for direct analysis of nonvolatile compounding agents in polymer matrices as an alternative to extraction procedures. FAB-MS was thus applied as a means for surface desorption/ionisation of vulcanisates. FAB is often not as effective as other ionisation methods (El, Cl, FI, FD), and FAB-MS is not considered particularly useful for extracted rubber additives analysis compared to other methods that are available [36], The effectiveness of the FAB technique has been demonstrated for the analysis of a live-component additive mixture [96]. [Pg.371]

In the deformulation of PE/additive systems by mass spectrometry, much less fragmentation was observed with DCI-MS/MS using ammonia as a reagent gas, than with FAB-MS [69]. FAB did not detect all the additives in the extracts. The softness and the lack of matrix effect make ammonia DCI a better ionisation technique than FAB for the analysis of additives directly from the extracts. Applications of hyphenated FAB-MS techniques are described elsewhere low-flow LC-MS (Section 7.3.3.2) and CE-MS (Section 7.3.6.1) for polar nonvolatile organics, and TLC-MS (Section 7.3.5.4). [Pg.371]

LSIMS is a more suitable ionisation technique than FD for analysis of mixtures by means of tandem mass spectrometry, because of the higher ion currents generated from polymer additives using LSIMS. LSIMS/MS experiments may be used in conjunction with FD-MS as a screen to determine class, molecular weight and structure of mixtures of organic polymer additives. [Pg.372]

Although FD was one of the earliest forms of soft ionisation, poor sensitivity and limited applicability have restricted the impact of the approach in the mainstream of mass spectrometry. More recently, many of the application areas of FD and FI have been appropriated by FAB-MS, which is generally considered to be a technique that requires less expertise alternatively, laser desorption is frequently being applied. FD-MS is only used in a handful of laboratories worldwide. The technique has recently been reviewed [107], and is subject of various monographs [108,112],... [Pg.375]

From the characteristics of the methods, it would appear that FD-MS can profitably be applied to poly-mer/additive dissolutions (without precipitation of the polymer or separation of the additive components). The FD approach was considered to be too difficult and fraught with inherent complications to be of routine use in the characterisation of anionic surfactants. The technique does, however, have a niche application in the area of nonpolar compound classes such as hydrocarbons and lubricants, compounds which are difficult to study using other mass-spectrometry ionisation techniques. [Pg.376]

This chapter deals mainly with (multi)hyphenated techniques comprising wet sample preparation steps (e.g. SFE, SPE) and/or separation techniques (GC, SFC, HPLC, SEC, TLC, CE). Other hyphenated techniques involve thermal-spectroscopic and gas or heat extraction methods (TG, TD, HS, Py, LD, etc.). Also, spectroscopic couplings (e.g. LIBS-LIF) are of interest. Hyphenation of UV spectroscopy and mass spectrometry forms the family of laser mass-spectrometric (LAMS) methods, such as REMPI-ToFMS and MALDI-ToFMS. In REMPI-ToFMS the connecting element between UV spectroscopy and mass spectrometry is laser-induced REMPI ionisation. An intermediate state of the molecule of interest is selectively excited by absorption of a laser photon (the wavelength of a tuneable laser is set in resonance with the transition). The excited molecules are subsequently ionised by absorption of an additional laser photon. Therefore the ionisation selectivity is introduced by the resonance absorption of the first photon, i.e. by UV spectroscopy. However, conventional UV spectra of polyatomic molecules exhibit relatively broad and continuous spectral features, allowing only a medium selectivity. Supersonic jet cooling of the sample molecules (to 5-50 K) reduces the line width of their... [Pg.428]

Smith and Udseth [154] first described SFE-MS in 1983. Direct fluid injection (DFT) mass spectrometry (DFT-MS, DFI-MS/MS) utilises supercritical fluids for solvation and transfer of materials to a mass-spectrometer chemical ionisation (Cl) source. Extraction with scC02 is compatible with a variety of Cl reagents, which allow a sensitive and selective means for ionising the solute classes of interest. If the interfering effects of the sample matrix cannot be overcome by selective ionisation, techniques based on tandem mass spectrometry can be used [7]. In these cases, a cheaper and more attractive alternative is often to perform some form of chromatography between extraction and detection. In SFE-MS, on-line fractionation using pressure can be used to control SCF solubility to a limited extent. The main features of on-line SFE-MS are summarised in Table 7.20. It appears that the direct introduction into a mass spectrometer of analytes dissolved in supercritical fluids without on-line chromatography has not actively been pursued. [Pg.451]

Plasmas compare favourably with both the chemical combustion flame and the electrothermal atomiser with respect to the efficiency of the excitation of elements. The higher temperatures obtained in the plasma result in increased sensitivity, and a large number of elements can be efficiently determined. Common plasma sources are essentially He MIP, Ar MIP and Ar ICP. Helium has a much higher ionisation potential than argon (24.5 eV vs. 15.8 eV), and thus is a more efficient ionisation source for many nonmetals, thereby resulting in improved sensitivity. Both ICPs and He MIPs are utilised as emission detectors for GC. Plasma-source mass spectrometry offers selective detection with excellent sensitivity. When coupled to chromatographic techniques such as GC, SFC or HPLC, it provides a method for elemental speciation. Plasma-source detection in GC is dominated by GC-MIP-AES... [Pg.471]


See other pages where Mass spectrometry ionisation techniques is mentioned: [Pg.728]    [Pg.695]    [Pg.728]    [Pg.695]    [Pg.259]    [Pg.113]    [Pg.4]    [Pg.36]    [Pg.328]    [Pg.329]    [Pg.477]    [Pg.395]    [Pg.753]    [Pg.425]    [Pg.535]    [Pg.533]    [Pg.353]    [Pg.370]    [Pg.372]    [Pg.378]    [Pg.381]    [Pg.384]    [Pg.392]    [Pg.405]    [Pg.406]    [Pg.408]    [Pg.410]    [Pg.411]    [Pg.411]    [Pg.455]    [Pg.461]    [Pg.464]   
See also in sourсe #XX -- [ Pg.37 , Pg.38 , Pg.39 , Pg.40 , Pg.41 ]




SEARCH



Ionisation

Ionisation spectrometry

Ionisation techniques

Ionisation techniques liquid chromatography-mass spectrometry

Ionised

Mass spectrometry desorption ionisation techniques

Mass spectrometry soft ionisation techniques

Mass spectrometry spray ionisation techniques

Mass spectrometry technique

© 2024 chempedia.info