Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Mass spectrometry spray ionisation techniques

For non-volatile sample molecules, other ionisation methods must be used, namely desorption/ionisation (DI) and nebulisation ionisation methods. In DI, the unifying aspect is the rapid addition of energy into a condensed-phase sample, with subsequent generation and release of ions into the mass analyser. In El and Cl, the processes of volatilisation and ionisation are distinct and separable in DI, they are intimately associated. In nebulisation ionisation, such as ESP or TSP, an aerosol spray is used at some stage to separate sample molecules and/or ions from the solvent liquid that carries them into the source of the mass spectrometer. Less volatile but thermally stable compounds can be thermally vaporised in the direct inlet probe (DIP) situated close to the ionising molecular beam. This DIP is standard equipment on most instruments an El spectrum results. Techniques that extend the utility of mass spectrometry to the least volatile and more labile organic molecules include FD, EHD, surface ionisation (SIMS, FAB) and matrix-assisted laser desorption (MALD) as the last... [Pg.359]

For these techniques, a dissolved sample is usually employed in the analysis to form a liquid spray which is delivered to an atomiser e.g. a flame or electrically generated plasma). Concerning optical spectrometry, techniques based on photon absorption, photon emission and fluorescence will be described (Section 1.2), while for mass spectrometry (MS) particular attention will be paid to the use of an inductively coupled plasma (TCP) as the atomisation/ionisation source (Section 1.3). The use of on-line coupled systems to the above liquid analysis techniques such as flow injection manifolds and chromatographic systems will be dealt with in Section 1.4 because they have become commonplace in most laboratories, opening up new opportunities for sample handling and pretreatment and also to obtain element-specific molecular information. [Pg.3]


See other pages where Mass spectrometry spray ionisation techniques is mentioned: [Pg.384]    [Pg.541]    [Pg.668]    [Pg.53]    [Pg.635]    [Pg.344]    [Pg.164]    [Pg.412]    [Pg.492]   
See also in sourсe #XX -- [ Pg.4 , Pg.482 ]




SEARCH



Ionisation

Ionisation spectrometry

Ionisation techniques

Ionisation techniques mass spectrometry

Ionised

Mass spectrometry technique

Spray technique

Spraying techniques

© 2024 chempedia.info