Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Selection analysis

Tandem mass spectrometry or ms/ms was first introduced in the 1970s and gained rapid acceptance in the analytical community. The technique has been used for stmcture elucidation of unknowns (26) and has the abiUty to provide sensitive and selective analysis of complex mixtures with minimal sample clean-up (27). Developments in the mid-1980s advancing the popularity of ms/ms included the availabiUty of powerhil data systems capable of controlling the ms/ms experiment and the viabiUty of soft ionisation techniques which essentially yield only molecular ion species. [Pg.405]

An important parameter in LC-LC is the transfer volume, i.e. the time that C-1 is coupled to C-2, since the selectivity is highly dependent on this. In environmental samples, it is important to remove early-eluting interference in order to ensure selective analysis. A short analysis time is important for routine analysis of environmental samples. [Pg.343]

Kunkel, E. J., Plavec, L, Nguyen, D., Melrose, J., Rosier, E. S., Kao, L. T., Wang, Y., Hytopoulos, E., Bishop, A. C., Bateman, R., et al. (2004). Rapid structure-activity and selectivity analysis of kinase inhibitors by Bio Map analysis in complex human primary cell-based models. ASSAY Drug Dev. Technol. 2 431-441. [Pg.197]

As in HPLC, the coupling of MS detection with CE has provided an excellent opportunity for more selective analysis, but the much reduced flow rates, small injection volumes, limitations in the types of buffers used [since electrospray ionization (ESI) is used in capillary electrophoresis/mass spectrometry (CE/MS)], and need to... [Pg.781]

Accurate, rapid, cheap, and selective analysis is required nowadays for clinical and industrial laboratories. Electrochemical biosensors seem to accomplish this function. [Pg.434]

The same procedure, or modifications of it, was used by Zak et al (80), Talseth (42,82,82,83), and Haegele et al (46) for metabolic studies. Zak et al (80) point out that hydrolysis of conjugates of the drug may cause analytical results on biological samples to be variable, depending on the acid concentration during derivatization, and that selective analysis for unchanged hydralazine and acid-labile metabolites can be carried out by suitable adjustment of the acid concentration. [Pg.308]

In addition to neutral loss scans, mass spectrometers can be used to detect other compounds in a different manner. Acylcamitines are fatty acid esters of carnitine. The masses of acylcamitines differ by the size of the fatty acid attached to it. The tandem mass spectrometer can detect these selectively as well because they all produce a similar product, in this case an ion rather than a molecule. Because it is an ion, it can be detected by the second mass separation device. The ion has a mass of 85 Da and is common to all acylcamitines. Performing a precursor ion scan of 85 Da (essentially a scan of only molecules that produce the 85 ion) reveals a selective analysis of acylcar-nitines, as shown in Fig. 14.2. Additional scans have been added to more selectively detect basic amino acids, free carnitine, short chain acylcamitines and a hormone, thyroxin (T4) which has amino acid components. [Pg.293]

Fraefel, A. Seibl, J. Selective Analysis of Metastable Ions. Mass Spectrom. Rev. 1984,4, 151-221. [Pg.186]

Hansen G, Christensen P, Tuchsen E, Lund T. 2004. Sensitive and selective analysis of coenzyme QlO in human serum by negative APCI LC-MS. Analyst 129 45. [Pg.170]

Breaux. E.I.. Patanella. I.E.. and Sanders. E.F. Chloroacetanilide herbicide selectivity analysis of glntathione and homoglutathione in tolerant, snsceptible and safened seedlings. J. Agric. Food Chem., 35(4) 474-478.1987. [Pg.1636]

This approach was first applied toward an understanding of discriminating interactions in the serine proteases factor Xa, thrombin and trypsin [108] and provided selectivity information for all important serine protease subpockets, which are in agreement to experimental selectivities of typical protease inhibitors. This approach was complemented by a 3-D-QSAR selectivity analysis on a series of 3-amidinobenzyl-lH-indole-2-carboxamides [107], which points, from the viewpoint of the ligands, to similar main interactions driving selectivity between key enzymes in the blood... [Pg.344]

QitTof enables mass-selective analysis by MS" analysis compared to TOFMS only. [Pg.227]

For these reasons, microbial sensors are less suitable for the determination of individual analytes. However, some practical apphcations for biosensors based on enzymes or antibodies for the specific determination of environmentally relevant compounds can be expected soon [11]. Furthermore, in some cases defined specific metabolic pathways in microorganisms are used, leading to microbial sensors for more selective analysis for those environmental pollutants which cannot be measured by the use of simple enzyme reactions, e.g., aromatic compounds and heavy metals. In this context it is also important to mention the aspect of bio availability, a parameter which is included by the measuring procedure of microbial sensors as an integral effect. [Pg.86]

Application of Free-Wilson Selectivity Analysis for Combinatorial Library Design... [Pg.91]

ICP-MS has been combined with flow injection and a selective extraction procedure (which isolates Alzheimer s amyloid plaques) for the selective analysis of plaque cores.103 The results of multi-element analysis indicate the accumulation of several elements (Al, Fe, Zn) in the plaques. [Pg.353]

HI Now we use a built-in routine in Excel for the paired t test to see if the two methods in Problem 4-14 produce significantly different results. Enter the data for Methods 1 and 2 into two columns of a spreadsheet. Under the TOOLS menu, select DATA ANALYSIS. If DATA ANALYSIS does not appear, select ADD-INS. Select ANALYSIS TOOLPACK, click OK, and DATA ANALYSIS will be loaded into the tools menu. In the DATA ANALYSIS window, select t-Test Paired Two Sample for Means. Follow the instructions of Section 4-5 and the routine will print out a variety of information including tcafcu ated (which is labeled t Stat) and ftable (which is labeled t Critical two-tail). You should reproduce the results of Problem 4-14. [Pg.75]

Turiel E, Martin-Esteban A, Tadeo JL (2007) Molecular imprinting-based separation methods for selective analysis of fluoroquinolones in soils. J Chromatogr A 1172(2) 97-104... [Pg.305]

The selective analysis of phenothiazines by oxidation to fluorescent products has been described for the HPLC determination of these compounds [40]. The method involves the separation of the drugs prior to oxidation, followed by fluorimetric determination of the products. [Pg.180]

Bonato and Paias [136] developed two sensitive and simple assay procedures based on HPLC and capillary electrophoresis for the enantio-selective analysis of omeprazole in pharmaceutical formulations. Racemic omeprazole and (S)-omeprazole were extracted from commercially available tablets using methanol-sodium hydroxide 2.5 mol/1 (90 10). Chiral HPLC separation of omeprazole was obtained on a ChiralPak AD column using hexane-ethanol (40 60) as the mobile phase and detection at 302 nm. The resolution of omeprazole enantiomers by capillary electrophoresis was carried out using 3% sulfated /1-cyclodextrin in 20 mmol/1 phosphate buffer, pH 4 and detection at 202 nm. [Pg.238]

Alternatively, one can characterize the catalytic intermediates in situ, under conditions that are closer to the real reaction conditions. Recent advances in high-pressure IR and NMR equipment, for example, enable the measurement of spectra at up to 200 bar and 150 °C, similar to the reaction conditions in high-pressure autoclaves [54], In some cases, one can combine the characterization with activity/selectivity analysis, examining the catalyst in real-time operation. This... [Pg.27]


See other pages where Selection analysis is mentioned: [Pg.231]    [Pg.165]    [Pg.499]    [Pg.401]    [Pg.451]    [Pg.368]    [Pg.462]    [Pg.152]    [Pg.403]    [Pg.157]    [Pg.364]    [Pg.76]    [Pg.81]    [Pg.93]    [Pg.95]    [Pg.97]    [Pg.99]    [Pg.101]    [Pg.103]    [Pg.103]    [Pg.105]    [Pg.107]    [Pg.109]    [Pg.368]    [Pg.38]    [Pg.37]    [Pg.291]    [Pg.62]   
See also in sourсe #XX -- [ Pg.169 ]




SEARCH



Amino acid analysis with selective

Amino acid analysis with selective electrodes

Analysis Techniques Using Ion-Selective Electrodes

Chemical analysis selection

Degree of Freedom Analysis and Variable Selection

Distributions, selection fixed-effects analysis

Distributions, selection random-effects analysis

Elemental analysis instrument selection

Environmental analysis improving selectivity

Event Selection for Safety Analysis

Example 5.1 Basic selection and data analysis procedures

Examples of Theoretical H-Bonding Analysis to Support Solid Form Selection

Flow injection analysis element selective detectors

Guidance for the selection of a factor analysis method

Numerical analysis selectivity dependence

PARAMETERS AFFECTING SELECTIVITY IN PROGRAMMED ANALYSIS

Parallel factor analysis selection

Plasma Analysis of Benazepril Using Gas Chromatography with Mass-Selective Detection (GC-MSD)

Process hazard analysis methodology selection

Process hazard analysis selection

Protein selectivity analysis

Protein structure analysis selection

Reaction Pathways, Catalyst Selection and Performance Example Analysis

Region selection analysis

Selected examples of impedance-analysis applications

Selected ion monitoring analysis

Selected targeted compound analysis

Selecting jobs, for analysis

Selecting the Jobs for Analysis

Selection of Analysis Method

Selection of Capillary Column for GC Analysis

Selection of Fuel Rods for Analyses

Selection of ions for selected-ion monitoring or full-scan analysis

Selection, data analysis and simulation by computer software

Selective analysis

Selective analysis

Selective precipitation qualitative analysis

Selective quantitative analysis

Selective serotonin reuptake inhibitors analysis

Selectivity analysis

Selectivity analysis

Selectivity analysis HRMS)

Selectivity analysis high-resolution mass spectrometry

Selectivity analysis liquid chromatography mass

Selectivity analysis mass spectrometric imaging

Selectivity analysis mass spectrometry

Selectivity analysis spectrometry

Selectivity multiple reactions, analysis

Selectivity of analysis

Specification Analysis and Model Selection

Statistical analysis and selection criteria

Surface analysis technique selection

Technique selection, corrosion surface analysis

The Analysis of Selected Events

Trace Element Analysis of Selected Elements and Speciation

Wavelength selection, near reflectance analysis

© 2024 chempedia.info