Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Samples presentation

Samples for infrared analysis can be solid, liquid or gas they can be analysed in solution or following separation. With the appropriate technique, environments can range from in situ measurements to the analysis of picogram quantities of material for forensic analysis. This versatility and power are unrivalled amongst other instrumental analytical techniques. [Pg.248]

We will now consider some of the more popular methods for sample preparation and presentation to the infrared beam. [Pg.248]


The x-ray diffractograms of those three samples are shown in Fig. 12. The lower pattern corresponds to the quenched sample where only the mesophase is present (the layer line, appearing at lower angles is not shown). The other two diagrams corresponding to the annealed samples present several sharp diffraction peaks, which... [Pg.389]

The results obtained for the proportion of a certain constituent in a given sample may form the basis of assessing the value of a large consignment of the commodity from which the sample was drawn. In such cases it is absolutely essential to be certain that the sample used for analysis is truly representative of the whole. When dealing with a homogeneous liquid, sampling presents few problems, but if the material under consideration is a solid mixture, then it is necessary to combine a number of portions to ensure that a representative sample is finally selected for analysis. The analyst must therefore be acquainted... [Pg.4]

Rubber compounds were made using A1 and A2 shown in Table 17.2 and using a model tire recipe shown in Table 17.4. The ingredients listed in Table 17.4 are in grams per 100 g of rubber (PHR). The mixing procedure used for the samples presented in Table 17.5. Both cured and un-cured compounds were tested and the mechanical testing results are shown in Table 17.6. [Pg.509]

A plot or graphical representation of the number of samples present in each activity range. Often shown as a population bar chart, it is used to provide an overview of the screening results and typically allows the determination of the overall BACKGROUND signal and threshold for selection of ACTIVE samples. [Pg.73]

All aqueous extracts are brown colored, and so is the Hillsborough River where samples of hydrilla are found. Examination of Table II, however, suggests that the location of the second peak in this water sample is significantly different from the other five samples. Presently, chromatograms of natural waters and the distribution of hydrilla are being obtained and compared with a view to being able to understand those factors that may limit the growth and spread of this noxious aquatic plant. [Pg.385]

Preliminary room temperature x-ray data of 0.65 Me4C00-PECH indicates that the sample presents a highly ordered smectic mesophase which was not yet completely assigned. The textures seen by polarized optical microscopy are also typical of smectic phases. Due to the very high molecular weights involved, textures specific to mesophase in thermodynamic equilibrium could not be developed within a reasonable amount of time by annealing. [Pg.116]

The technique is not optimal the instrument response (Y) is a predictor of analyte values (X). The limitation for modeling is in the representation of calibration set chemistry, sample presentation, and unknown variations of instrument and operator during measurement. [Pg.381]

Monleon E, Monzon M, Hortells P, et al. Detection of PrPsc in samples presenting a very advanced degree of autolysis (BSE liquid state) by immunocytochemistry. J. Histochem. Cytochem. 2003 51 15-18. [Pg.45]

It appeared that the chemical composition was close to the theoretical one. Surface area values decreased from Mg to Sr samples, which are related to the calcination temperatures necessary to eliminate the nitrate anions and organic compounds. Moreover, the SG samples presented higher surface area than the evaporated ones, although the calcination temperatures were higher (Table 1). [Pg.299]

According to detailed XRD analyses, the two catalyst preparation procedures under study formed solid solutions. The application of sol-gel method led to improved selectivity to olefins in the reaction of propane ODH, compared to the simple procedure of evaporation and decomposition. However, the propane conversion on the sol-gel catalysts was lower at the same experimental conditions, while the catalysts surface area was higher. Moreover, the sol-gel samples presented higher basicity as shown by C02 TPD. It could be explained by a better incorporation of Nd into the AEO lattice, creating cationic vacancies for attaining electroneutrality and thus rendering the nearby oxide anions coordinatively unsaturated and more basic. [Pg.302]

Table 10.1 Compounds trapped by headspace SPME from different resins, gum resins and archaeological samples, presented by Increasing retention indices, with the corresponding relative peak areas (%) for each substance... [Pg.266]

All carbon samples could easily be oxidized to C02, a form of the sample greatly preferred by most users, for many reasons. Neither the on-line or dedicated electrostatic accelerators under construction have succeeded in overcoming the problem of too much memory of C02 gas. Consequently, the sample presented to the cesium sputter beam source will probably have to be a solid. The cesium sputter source is the most likely to be used because it can produce negative ions of carbon in microampere beams. [Pg.96]

An exact source for the anomalous metal content and the gold grains in the samples presented here cannot be... [Pg.22]


See other pages where Samples presentation is mentioned: [Pg.19]    [Pg.19]    [Pg.359]    [Pg.107]    [Pg.389]    [Pg.390]    [Pg.45]    [Pg.962]    [Pg.105]    [Pg.637]    [Pg.349]    [Pg.339]    [Pg.157]    [Pg.202]    [Pg.591]    [Pg.95]    [Pg.261]    [Pg.66]    [Pg.35]    [Pg.254]    [Pg.192]    [Pg.50]    [Pg.110]    [Pg.324]    [Pg.222]    [Pg.449]    [Pg.64]    [Pg.116]    [Pg.117]    [Pg.111]    [Pg.341]    [Pg.504]    [Pg.522]    [Pg.110]    [Pg.316]    [Pg.163]    [Pg.368]   
See also in sourсe #XX -- [ Pg.313 ]




SEARCH



Direct stop-flow sample presentation

Rubbers sample presentation method

Sample Document Presenting PSM to Senior Management

Sample Presentation for Photostability Studies Problems and Solutions

Sample preparation and presentation

Sample presentation error

Sample presentation geometries

Single molecule fluorescence experiments sample presentation

© 2024 chempedia.info