Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Fluorescence spectrometry chromatography

Method abbreviations D-AT-FAAS (derivative flame AAS with atom trapping), ETAAS (electrothermal AAS), GC (gas chromatography), HGAAS (hydride generation AAS), HR-ICP-MS (high resolution inductively coupled plasma mass spectrometry), ICP-AES (inductively coupled plasma atomic emission spectrometry), ICP-MS (inductively coupled plasma mass spectrometry), TXRF (total reflection X-ray fluorescence spectrometry), Q-ICP-MS (quadrapole inductively coupled plasma mass spectrometry)... [Pg.219]

It has been reported that the differential determination of arsenic [36-41] and also antimony [42,43] is possible by hydride generation-atomic absorption spectrophotometry. The HGA-AS is a simple and sensitive method for the determination of elements which form gaseous hydrides [35,44-47] and mg/1 levels of these elements can be determined with high precision by this method. This technique has also been applied to analyses of various samples, utilising automated methods [48-50] and combining various kinds of detection methods, such as gas chromatography [51], atomic fluorescence spectrometry [52,53], and inductively coupled plasma emission spectrometry [47]. [Pg.339]

Techniques for analysis of different mercury species in biological samples and abiotic materials include atomic absorption, cold vapor atomic fluorescence spectrometry, gas-liquid chromatography with electron capture detection, and inductively coupled plasma mass spectrometry (Lansens etal. 1991 Schintu etal. 1992 Porcella etal. 1995). Methylmercury concentrations in marine biological tissues are detected at concentrations as low as 10 pg Hg/kg tissue using graphite furnace sample preparation techniques and atomic absorption spectrometry (Schintu et al. 1992). [Pg.355]

J. Gomez-Ariza, M.-A. Caro-de-la-Torre, I. Giraldez and E. Morales, Speciation analysis of selenium compounds in yeasts using pressurized liquid extraction and liquid chromatography-microwave-assisted digestion-hydride generation-atomic fluorescence spectrometry. Anal. Chim. Acta, 524(1-2), 2004, 305-314. [Pg.145]

E. Ramalhosa, S. Rio Segade, E. Pereira, C. Vale and A. Duarte, Simple methodology for methylmercury and inorganic mercury determinations by high-performance liquid chromatography-cold vapour atomic fluorescence spectrometry. Anal. Chim. Acta, 448(1-2), 2001, 135-143. [Pg.157]

LAB 11 Laboratory for analysis of unfiltered water samples, stream sediment and floodplain sediment samples. Ion chromatography (IC) is used for Cf, Br, N03% N02, P043, S042 and ion specific electrode (ISE) for F and Total Organic Carbon (TOC) in water. X-Ray fluorescence spectrometry (XRF) analyses for over 30 elements is used for stream sediment and floodplain sediment samples. To be nominated (suggestion British Geological Survey). [Pg.32]

Figure 6.1 Bar-graph of MeHg in CRM 580. The results correspond to six replicate determinations as performed by different laboratories using various methods. MEANS indicates the mean of laboratory means with 95% confidence interval. Abbreviations-. CVAAS, cold vapour atomic absorption spectrometry CVAFS, cold vapour atomic fluorescence spectrometry ECD, electron capture detection GC, gas chromatography HPLC, high-performance liquid chromatography ICPMS, inductively coupled plasma mass spectrometry MIP, microwave induced plasma atomic emission spectrometry QFAAS, quartz furnace atomic absorption spectrometry SFE, supercritical fluid extraction. Figure 6.1 Bar-graph of MeHg in CRM 580. The results correspond to six replicate determinations as performed by different laboratories using various methods. MEANS indicates the mean of laboratory means with 95% confidence interval. Abbreviations-. CVAAS, cold vapour atomic absorption spectrometry CVAFS, cold vapour atomic fluorescence spectrometry ECD, electron capture detection GC, gas chromatography HPLC, high-performance liquid chromatography ICPMS, inductively coupled plasma mass spectrometry MIP, microwave induced plasma atomic emission spectrometry QFAAS, quartz furnace atomic absorption spectrometry SFE, supercritical fluid extraction.
A number of techniques have been used for the speciation of arsenic compounds. The most important has been the formation of volatile hydrides of several species, separation by gas chromatography and detection by AAS. HPLC has been used to separate arsenic species. Several types of detectors have been studied for the determination of arsenic species in the column effluent. These have included AAS both off- and on-line, ICPAES and ICP-MS. An important comparative study of coupled chromatography-atomic spectrometry methods for the determination of arsenic was published (Ebdon et al., 1988). Both GC and HPLC were used as separative methods, and the detectors were FAAS, flame atomic fluorescence spectrometry (FAFS) and ICPAES. The conclusions were (1) that hydride generation and cryogenic trapping with GC-FAAS was the most... [Pg.415]

Fluorescence spectrometry is used in both research and surveillance to help assure both the farmer and the consumer a continued bounty of high quality agricultural products while preserving the quality of the environment. My objective is to discuss some of our current research and to share with you several interesting observations where we have used fluorescence as a monitor in high performance liquid chromatography. [Pg.103]

E. Moreno, C. Camara, W. T. Cores, D. W. Bryce, P. Stockwell, Arsenic speciation in beverages by direct injection-ion chromatography-hydride generation atomic fluorescence spectrometry, J. Autom. Met. Manag. Chem., 22 (2000), 33-39. [Pg.496]

E. Puskel, Z. Mester, P. Fodor, Determination of selenoamino acids by high-performance liquid chromatography-hydraulic high pressure nebulization-atomic fluorescence spectrometry, J. Anal. Atom. Spectrom., 14 (1999), 973-976. [Pg.666]

R. Ritsema, O. X. F. Donard, On-line speciation of mercury and methylmercury in aqueous samples by chromatography atomic fluorescence spectrometry after hydride generation, Appl. Organomet. Chem., 8 (1994), 571-576. [Pg.723]

P. Krystek, R. Ritsema, Mercury speciation in thawed out and refrozen fish samples by gas chromatography coupled to inductively coupled plasma mass spectrometry and atomic fluorescence spectrometry, Anal. Bioanal. Chem., 381 (2005), 354-359. [Pg.724]

L. N. Liang, G. B. Jiang, J. G. Liu, J. T. Hu, Speciation analysis of mercury in seafood by using high-performance liquid chromatography on-line coupled with cold-vapor atomic fluorescence spectrometry via a post column microwave digestion, Anal. Chim. Acta, Ml (2003), 131-137. [Pg.726]

Simon, S., Barats, A., Pannier, F., Potin-Gautier, M. Development of an on-line UV decomposition system for direct coupling of liquid chromatography to atomic-fluorescence spectrometry for selenium speciation analysis. Anal. Bioanal. Chem. 383, 562-569 (2005)... [Pg.222]

Vinas, P., Lopez-Garcia, I., Merino-Merofio, B., Campillo, N., Hemandez-Cordoba, M. Determination of selenium species in infant formulas and dietetic supplements using liquid chromatography-hydride generation atomic fluorescence spectrometry. Anal. Chim. Acta 535,49-56 (2005)... [Pg.235]

The theory of rotation effects on prolate luminescent molecules in solution and its experimental verification have been developed and compared. Generalized diffusion equations for the rotational motion of an asymmetric rigid motor have been used to given an expression for steady-state fluorescence depolarization. " The radiationless transition from the first excited singlet state of Eosin has been measured by optoacoustic relaxation, and the absolute fluorescence quantum yields of organic dyes in poly(vinyl alcohol) have also been measured by the photoacoustic method. The accuracy of the method has been discussed in the latter paper. Actinometry in flash photolysis experiments has been assisted by new measurements on the extinction coefficient of triplet benzophenone. Matrix-isolation fluorescence spectrometry has been used to detect polycyclic aromatic hydrocarbons from gas chromatography. ... [Pg.6]

Fig. 2 Chromatogram of a standard mixture after complexa-tion with sodium diethyldithiocarbamate. Composition of the standard mercury dichloride, methylmercury chloride, ethyl-mercury chloride, methoxyethylmercury chloride, ethoxyethyl-mercury chloride, phenylmercury chloride, and tolymercury chloride. [Reprinted from A. Knochel and H. Potgeter, Interfacing supercritical fluid chromatography with atomic fluorescence spectrometry for the determination of organomercury compounds,/. Chromatogr. A 786 192 (1997). Copyright 1997, with permission from Elsevier Science.]... Fig. 2 Chromatogram of a standard mixture after complexa-tion with sodium diethyldithiocarbamate. Composition of the standard mercury dichloride, methylmercury chloride, ethyl-mercury chloride, methoxyethylmercury chloride, ethoxyethyl-mercury chloride, phenylmercury chloride, and tolymercury chloride. [Reprinted from A. Knochel and H. Potgeter, Interfacing supercritical fluid chromatography with atomic fluorescence spectrometry for the determination of organomercury compounds,/. Chromatogr. A 786 192 (1997). Copyright 1997, with permission from Elsevier Science.]...
Chapter 11 details the relevant methods of analysis for both metals and organic compounds. For elemental (metal) analysis, particular attention is given to atomic spectroscopic methods, including atomic absorption and atomic emission spectroscopy. Details are also provided on X-ray fluorescence spectrometry for the direct analysis of metals in solids, ion chromatography for anions in solution, and anodic stripping voltammetry for metal ions in solution. For organic compounds,... [Pg.276]

Beltran JL, Guiteras J, Ferrer R, Three-way multivariate calibration procedures applied to high-performance liquid chromatography coupled with fast-scanning fluorescence spectrometry detection. determination of polycyclic aromatic hydrocarbons in water samples, Analytical Chemistry, 1998b, 70,1949-1955. [Pg.352]

Sensor types ISE, QCM, SAW, single-X spectroscopy sensor arrays (QCM, SAW, ISE) multi-X spectroscopy, mass spectrometry, chromatography GC-MS excitation-emission- fluorescence... [Pg.292]


See other pages where Fluorescence spectrometry chromatography is mentioned: [Pg.231]    [Pg.79]    [Pg.531]    [Pg.701]    [Pg.127]    [Pg.144]    [Pg.205]    [Pg.139]    [Pg.229]    [Pg.413]    [Pg.8]    [Pg.630]    [Pg.390]    [Pg.534]    [Pg.231]    [Pg.443]    [Pg.14]    [Pg.542]    [Pg.554]    [Pg.1061]    [Pg.3]    [Pg.405]    [Pg.247]    [Pg.413]   
See also in sourсe #XX -- [ Pg.84 , Pg.84 ]




SEARCH



Fluorescence spectrometry

© 2024 chempedia.info