There is a great difference between various simulators (5) in terms of how easily and how well the hypothetical calculation units can be incorporated in the simulation. The trial-and-error calculations, which ate called iterative calculations, do not always converge for every flow sheet being simulated. Test problems can be devised to be tried with various simulators to see if the simulator will give a converged solution (11). Different simulators could take different numbers of iterations to converge and take different amounts of computet time on the same computet. [Pg.73]

General Properties of Computerized Physical Property System. Flow-sheeting calculations tend to have voracious appetites for physical property estimations. To model a distillation column one may request estimates for chemical potential (or fugacity) and for enthalpies 10,000 or more times. Depending on the complexity of the property methods used, these calculations could represent 80% or more of the computer time requited to do a simulation. The design of the physical property estimation system must therefore be done with extreme care. [Pg.75]

In the initial stages of the process design and evaluation, when only a rough, approximate, material balance is required, the use of a full simulation program is often not justified. Simpler programs, which calculate only the material balance, have been developed and these can be used as an aid to manual flow-sheeting calculations. They will be particularly useful if the process involves several recycle streams. [Pg.168]

Some of the full simulation flow-sheeting packages can also be used to calculate the material balance without simultaneous solution of the energy balance, or use of the equipment design routines. They should be used in this mode for the initial, scouting, flow-sheet calculations, to economise on computing costs. [Pg.168]

Most flow sheets have one or mote recycles, and trial-and-ettot becomes necessary for the calculation of material and energy balances. The calculations in a block sequential simulator ate repeated in this trial-and-ettot process. In the language of numerical analysis, this is known as convergence of the calculations. There ate mathematical techniques for speeding up this trial-and-ettot process, and special hypothetical calculation units called convergence, or recycle, units ate used in calculation flow diagrams that invoke special calculation routines. [Pg.73]

The simulation models of the flow-sheeting system must make frequent requests for properties at specific temperatures, pressures, and compositions. Computer-program calls for such data are usually made in a rigorously defined manner, which is independent of both the point data generation models and the particular components. These point generation routines provide the property values, using selected methods that base their calculations on a set of parameters for each component. [Pg.76]

Many industrial separations require a series of columns that are connected in specific ways. Some distillation programs can model such a system as a hypothetical single column with arbitrary cross-flows and connections and then carry out the distillation calculations for the modeled hypothetical column. Alternatively, such a system can be modeled as a process flow sheet using a process simulator. [Pg.78]

In 2006, GA participated in a study conducted by the Savannah River National Laboratory (Summers, 2006). The S-I process was coupled to a VHTR with a required helium return temperature near 600°C. To efficiently match temperature requirements with available heat, a design was developed to supply HI decomposition section energy with recovered heat from the sulphuric acid decomposition section. For the purposes of comparison and analysis in this paper, the GA flow sheets will refer to this design, and CEA flow sheets will refer to a design in which helium supplies heat to both acid decomposition sections. CEA uses ProSimPlus for flow sheet analysis, and GA uses Aspen Plus . A previous study (Buckingham, 2008) showed that the two process simulators give similar calculated results when the same unit operations and stream compositions are modelled, although different thermodynamic models are used for the calculations. [Pg.183]

The computational architecture is a sequential modular approach with advanced features. To model a process, each equipment module is simulated by a program module. The overall process is simulated by connecting the models together in the same way as the equipment in the flow sheet. When the input streams are known then the outputs can be calculated. The entire flowsheet can be calculated "sequentially" in this manner. Advanced features are discussed below in connection with an example. [Pg.291]

The simulation of a multi-component system was done with the flow sheeting program Aspen+. An external routine replaced the internal Kj-calculation with a fit function through the experimental Revalues as given in figure 4. The multistage column was split into a cascade of flash modules. Each module is connected to two other... [Pg.295]

The advantage of process simulator calculations comes when the sequence of process steps has been set. The process simulator draws the process flow sheet specified and uses it to fix the computer algorithm for the process. There are optimization strategies to select the best conditions of the feed streams to the equipment and operating conditions for the whole process. [Pg.818]

For steady-state simulations, several solution methods have been used. The one most frequently used is the sequential approach. In this method, numerical modules are used that calculate the output stream of a process unit from the input streams coupled with any additional information that is required to uniquely define the performance of the process unit. The simulation treats one unit model at a time. For a simulation flow sheet consisting of interconnected units, the order... [Pg.1951]

Detailed information can be obtained using the View/Report menu. This gives details about individual blocks. The View/History menu gives information about the convergence and what calculations have been done. The View/Input Summary lists the parameters you have set. Every report should have a flow sheet with blocks and streams labeled, mass and energy balances referenced to the flow sheet, and a text description of the process. You should outline the problem, describe the choices you have made, and list all the ways you examined your results for validity. When you are really done, you can choose File and Export. In the Save as type window, scroll down to report Files (. rep see Fig. C.l 1). Save that. It creates a text version of the whole simulation, giving aU the detail you supplied and all the results. It is very useful to document your work (perhaps as an Appendix in a report), and the report gives the detail needed to... [Pg.266]

A simulation of a DWC based on the equivalent Petlyuk column has two recycle loops, which requires two recycle blocks (R1 and R2), as shown in Figure 9.6b. The prefractionator column (Pref) has neither reboiler nor condenser, which can be simulated using an absorber column. This column has two recycle streams, which includes a recycled vapor stream to a prefractionator (Vapor pre in) at the bottom, and the recycled liquid stream to the prefractionator (Liquid pre in) at the top. These two streams need the initial estimates to solve the Pref column. A distillation unit for the main column, the material streams. Feed, Vapor pre out. Liquid pre out. Liquid Main out. Vapor Main out. Distillate, Side, and Bottom for Main column are added to the flow sheet. Two recycle blocks need to be added to the flow sheet one recycle block (Rl) for the Liquid Main out and another (R2) for Vapor Main out to initialize the recycle stream. Once the Pref is solved, the main column is simulated with an estimated number of stages and stage locations from the shortcut calculation. [Pg.262]

The main column has five degrees of freedom, and so five specifications should be provided. The purity and recovery of the main product are normally used as specifications. The flow rates of Liquid Main out and Vapor Main out are also considered as specifications. The streams Liquid Main out and Vapor Main out are calculated and available for further calculations. Consequently, the complete flow sheet in Figure 9.6b can converge due to two recycle blocks. Whenever the initial estimates obtained from the shortcut simulation do not lead to the convergence of a rigorous simulation, small changes in these estimates need to be attempted to achieve convergence. [Pg.262]

Material and energy flow analyses with material flow analysis tools and flow sheet simulation systems are carried out to assess as well as to balance and configure technical processes. Economic evaluations are based on the results material and energy flow analyses. Examples for such works are [39, 75]. To determine investments and raw material, energy and total production costs as well as revenues static and dynamic investment calculation methods are carried out... [Pg.88]

Figure 3 shows the equilibrium reformate composition at different temperatures based on stationary process flow sheet simulations (ChemCAD ). The flow rate ratio of AOG to propane has been kept constant at a calculated (0/C)Ref of 1.82. Hydrocarbon conversion is almost complete for reforming temperatures above 700 C. The fraction of H2 and CO is greater than 60 Vol.-%. Soot formation is inhibited above 720 °C for the distinct operation conditions. [Pg.3]

Additionally, there is process simulation steady-state flow sheet simulators and dynamic flow sheet simulators. Steady-state flow sheet simulators have been widely used in chemical process engineering since the 1960s. Steady-state simulators describe the process as a set of modules connected by flows of material and energy between them. The modules correspond to mass and energy balances together with physical and thermodynamic data necessary for calculations. The calculations may be performed using one of two basic techniques. The sequential approach computes modules one by one, in a direction that generally follows that of the physical flows in the system (Leiviska, 1996). [Pg.63]

Flow sheeting, as used in CAD, means performing on a specified flow sheet, the calculations necessary to simulate the behavior of the process. These calculations include mass and energy balances. [Pg.191]

The packed height is calculated by selecting Flow sheeting options and then Design specification as shown in Figures 7.53 through 7.55. The simulated column diameter is shown in Figure 7.56. [Pg.372]

It is worth pointing out that the fluid flow in our calculations of the merger (Rosswog et al. 2003) never becomes axisymmetric during the simulation and therefore Cowlings anti-dynamo theorem does not apply here. When the surfaces of the neutron stars come into contact, a vortex sheet forms between them... [Pg.323]

Figure 10.15 shows the simulated temperature distribution in the electrolyte for the single-cell stack model. In this calculation, the cell operating voltage is set at 0.16 V at which the electrolyte sheet cracked in the internal heat evolution test. In Figure 10.15, it can be observed that the temperature is almost 1273 K outside the anode/electrolyte/cathode area where heat is generated. Near the fuel inlet at the channel, the temperature increases steeply and the maximum temperature spreads over a wide area to the downstream of the fuel flow the maximum temperature difference in the electrolyte is around 60 K. [Pg.348]


See other pages where Flow-sheet calculations simulation is mentioned: [Pg.815]    [Pg.526]    [Pg.73]    [Pg.168]    [Pg.293]    [Pg.526]    [Pg.112]    [Pg.164]    [Pg.112]    [Pg.1950]    [Pg.274]    [Pg.383]    [Pg.385]    [Pg.54]    [Pg.49]    [Pg.165]    [Pg.195]    [Pg.196]    [Pg.356]    [Pg.880]    [Pg.41]    [Pg.379]    [Pg.868]    [Pg.279]    [Pg.333]   