Flow monitoring devices

Install differential pressure or flow monitoring device to indicate flow into/out of vent... [Pg.75]

J.S. Rossier, P. Morier and F. Reymond, Patent Microfluidic Flow Monitoring Device, 2003, WO 2003/004160 A004161. [Pg.905]

The Agilent 1100 Capillary LC works by splitting the relatively high flow rates to the column. The instrument utilizes a novel flow-monitoring device, called an electronic flow control, which monitors the... [Pg.2546]

Equip each exhaust flow vent system with a continuous air flow monitoring device to detect any loss in air flow Tie the system into the site emergency power system. [Pg.317]

The principal requirement of a sampling system is to obtain a sample that is representative of the atmosphere at a particular place and time and that can be evaluated as a mass or volume concentration. Remote monitoring techniques are discussed in Chapter 15. The sampling system should not alter the chemical or physical characteristics of the sample in an undesirable manner. The major components of most sampling systems are an inlet manifold, an air mover, a collection medium, and a flow measurement device. [Pg.179]

Educate patients on the use of inhaled drug delivery devices, peak flow monitors, and asthma education plans. [Pg.209]

Finally, current design of hazardous waste incinerators includes various safeguards, such as process monitoring devices (to monitor parameters such as temperature, air flow, and operating... [Pg.957]

The detection and alarm circuits of fire and gas detection systems should be continuously supervised to determine if the system is operable. Normal mechanisms provide for a limited current flow through the circuits for normal operation. During alarm conditions current flow is increased while during failure modes the current level is nonexistence. By measuring levels at a control point the health of the circuit or monitoring devices can be continuously determined. End-of-line-resistors (EOLR) are commonly provided in each circuit to provide supervisory signal levels to the control location. [Pg.192]

Variable-flow-rate device must be available to monitor flow rate,... [Pg.457]

The second-order rate constants k for the base hydrolysis of a number of cobalt(lll) complexes were measured with a simple flow apparatus using conductivity as a monitoring device. Equal concentrations (Ag) of reactants were used. Show that a plot of R,/R — R, vs time is linear, having slope s, and that... [Pg.195]

The stopped-flow method uses syringe-type pumps, (a), to feed the components, A and B, through a mixing cell, (c), into the reaction cell, (d), which can be an optical cell (Fig. 3.3-5). The pumps, mixing cell, and reactor are well thermostatted. The flow is stopped when the syringe, (e), is loaded and operates a switch, (f), to start the monitoring device. The change in concentration is detected either by spectroscopy or conductivity measurement. [Pg.85]

Flow assemblies are recommended for housing a conductivity cell, pH/ORP probes, or other monitoring devices. However, they should be designed and installed for easy physical access and cell/electrode cleaning. Flow assemblies should also incorporate a sample port. [Pg.358]

Acid can be injected into a flow assembly, but not to the same unit housing any other monitoring device, or other chemical injection port. An alternative is to add acid directly into a forebay, or the cooling tower sump (at a point of rapid mixing, but away from the pump suction, or chlorine/bromine discharge point, or bleed valve). [Pg.359]

Identification of sewers, discharge locations and inputs to the final effluent or ETP (if one exists). The main streams and inputs to the ETP (if present) should be identified, along with sub-component streams (information should already be available as part of a Toxicity Prevention/Response Plan described in Section 5.1). Inputs should include process, site-runoff, stormwater runoff and groundwater sources. A description of the process and operation at each location should also be provided (including operation frequency). Locations with existing monitoring equipment and flow control devices should also be identified. [Pg.197]

Molders utilizing this system require equipment to measure and control the amount of entrained gas in the liquid at the desired level. They can include mass flow meters with density devices, nuclear density monitoring devices, as well as a variety of other densities measuring devices to control nucleation level. All these systems work within very defined pressure and temperature limits however, outside these limits, readings become erratic. There are systems that remove the dependence on system pressure and temperature. This system provides more consistent data. [Pg.417]

A typical immunoassay format in a flow-through device has an antibody covalently coupled to the surface of a porous matrix. When the patient sample is added to the matrix, the analyte of interest binds to the antibody. Addition of a second labeled antibody forms a sandwich and traps the label at the position of the first antibody. If the label is gold sol particles or colored latex, the label is directly visualized or quantified by reflectance spectrophotometry in a separate reader, Another important feature of this type of technology is the incorporation of a built-in quality monitor that indicates positive if all the reagents have been stored and the device operated correctly. In all these different formats,... [Pg.303]

The monitoring devices for the first subdivision have been rendered inoperable. Given an overall canal flow of 6400 gpm (gallons per minute) with an organics load of 240 mg/L, estimate the flow and organics load in the first sewer if the other two sewers are measured at 1850 gpm with 280 mg/L organics and 2250 gpm with 210 mg/L organics. [Pg.84]

A comprehensive GC X 2GC technique with differential flow modulation has been developed for rapid analysis of VOCs. " In comprehensive GC X 2GC, two secondary columns of different polarities are used, requiring a GC with two detectors to monitor the column effluents. The flow-switching device is a modification of the unit developed by Sacks and Akard " for high-speed chromatography. The flow of carrier gas to the columns is controlled by a three-port solenoid valve placed outside the GC oven and not in the sample flowpath. Parallel and serially positioned tee unions control the flows of carrier and auxiliary gases and interface the primary column effluent to the secondary columns. Bueno and Seeley " used a 5.0 m X 0.25 mm i.d. capillary column with a... [Pg.631]

Certain limitations were also inherent to these studies. Care had to be taken that measuring devices did not Interfere with, or in any way compromise the safety equipment or protective devices that would otherwise be utilized, and field technicians had to remain passive observers who neither advised nor assisted in any of the tasks under study. Beoause time, itself, is a valuable commodity, manipulations involving the monitoring devices could not unduly interfere with the normal flow of operations on the projects. [Pg.298]

Over the past 10 years, electronic inhaler monitoring devices have been developed which record the date and time of actuations and can then be downloaded onto a computer. A record can then be printed which reflects a patient s pattern of inhaler use over a period of time. Electronic peak flow meters are also available which record and store peak flow values, along with date and time information. While these devices have generally been utilized exclusively for research, improved technologies are increasingly making their clinical application feasible. [Pg.454]


See other pages where Flow monitoring devices is mentioned: [Pg.511]    [Pg.54]    [Pg.511]    [Pg.54]    [Pg.490]    [Pg.21]    [Pg.47]    [Pg.89]    [Pg.459]    [Pg.358]    [Pg.359]    [Pg.257]    [Pg.280]    [Pg.420]    [Pg.683]    [Pg.305]    [Pg.593]    [Pg.58]    [Pg.69]    [Pg.161]    [Pg.137]    [Pg.721]    [Pg.181]    [Pg.747]    [Pg.141]    [Pg.277]    [Pg.455]    [Pg.455]    [Pg.220]    [Pg.374]    [Pg.73]   
See also in sourсe #XX -- [ Pg.511 ]