Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Flow injection chemiluminescence

Ma Y, Zhou M, Jin X et al (2004) Flow-injection chemiluminescence assay for ultra-trace determination of DNA using rhodamine B-Ce(IV)-DNA ternary system in sulfuric acid media. Anal Chim Acta 501 25-30... [Pg.64]

A system based on microdialysis coupled with flow-injection chemiluminescence detection allows for direct sampling of unbound drug without extractive sample preparation [72], A similar approach based on continuous ultrafiltration has also been reported [73]. Modifications designed to overcome challenges of low solubility and high-non-specific binding in the ultrafiltration approach have also been described [74]. [Pg.499]

E. P. Achterberg, P. N. Sedwick, S. Ussher, and P. J. Worsfold, Real-Time Monitoring of Picomolar Concentrations of Iron(lI) in Marine Waters Using Automated Flow Injection-Chemiluminescence Instrumentation, Environ. Sci. TechnoL 2002,36, 4600. [Pg.677]

Fang and co-workers [115] have reported a flow injection chemiluminescence assay for the detection of maleic hydrazide (MH). The imprinted poly(MAA-co-EDMA) polymer selectively retained the herbicide that was further treated with alkaline luminol-potassium periodate to produce a strong CL signal. Upon reaction, the absorbed MH was destroyed and removed by the flowing solution. The polymer was reused up to ten times and the linear response was between 3.5 x 10 and 5.0 x 10 2 mg mL-1 with a detection limit of 6.0 x 10 5 mg mL-1. The CILA flow injection system was used for the analysis of potato and onion samples spiked with 1.0, 2.0, and 4.0 x 10-3 mg mL-1 of MH. Recoveries ranged from 98% to 103% (RSD 2.3%), demonstrating the successful application of the method. [Pg.155]

Nie et al. used a flow injection chemiluminescence method for the determination of dipyridamole in Persantin tablets [51]. A flow injection analysis system equipped with a chemiluminescence detector was used. Sodium hypochlorite was used as a chemiluminescent substance, and Triton X-100 was used as an enhancer of the chemiluminescence reaction. Sample solutions (pH 4-6) was injected into 0.2% Triton X-100 and treated with 0.5% sodium hypochlorite, and the chemiluminescence intensity then measured. The calibration graph was linear from 0.04 to 10 pg/mL of Persantin tablets (as its active ingredient dipyridamole), with a detection limit of 11 ng/mL. Recoveries were quantitative and the relative standard deviation ( = 3) was 2.7%. The method has been used to determine Persantin in injection and tablets, and the results obtained using this method agreed with those obtained by the Chinese Pharmacopoeial method. [Pg.263]

O. Nozaki, H. Kawamoto and H. Moriyama, Total free catecholamines assay by identiflcation of its two functional groups and micro-flow injection chemiluminescence. Luminescence, 14, 369-374 (1999). [Pg.125]

Nozaki O, Kawamoto H. Determination of hydrogen peroxide by micro flow injection - chemiluminescence coupled the flow cell r., actor in a chemiluminometer. Luminescence 2000 15 137-42. [Pg.515]

Nozaki O, Kawamoto H. Reactivation of horseradish peroxidase with imiaazole for continuous determination of hydrogen peroxide using a micro-flow injection -chemiluminescence detection system. Luminescence 2003 18 203-6. [Pg.515]

F.R.P. Rocha, E. Rodenas-Torralba, B.F. Reis, A. Morales-Rubio, M. de La Guardia, A portable and low cost Equipment for flow injection chemiluminescence measurements, Talanta 67 (2005) 673. [Pg.40]

A. Townshend, J.A.M. Pulgarin, M.T.A. Pardo, Flow injection-chemiluminescence determination of propranolol in pharmaceutical preparations, Anal. Chim. Acta 488... [Pg.94]

J.L. Lopez-Paz, M. Catala-Icardo, B. Anton-Garrido, Determination of diquat by flow injection chemiluminescence, Anal. Bioanal. Chem. 394 (2009) 1073. [Pg.144]

X.W. Zheng, Z.J. Zhang, B.X. Li, Flow injection chemiluminescence determination of captopril with in situ electrogenerated Mn if as the oxidant, Electroanal. 13 (2001) 1046. [Pg.423]

C.X. Zhang, J.C. Fluang, Z.J. Zhang, M. Aizawa, Flow injection chemiluminescence determination of catecholamines with electrogenerated hypochlorite, Anal. Chim. Acta 374 (1998) 105. [Pg.423]

B.-X. Li, Z.-J. Zhang, W. Liu, Flow-injection chemiluminescence determination of manganese(II) in natural waters with solid bismuthate as an oxidant, Anal. Sci. 17 (2001) 1347. [Pg.424]

G.M. Greenway, T. Leelasattarathkul, S. Liawruangrath, R.A. Wheatley, N. Youngvises, Ultrasound-enhanced flow injection chemiluminescence for determination of hydrogen peroxide, Analyst 131 (2006) 501. [Pg.426]

B. Godlewska-Zylkiewicz, J. Malejko, B. Lesniewska, A. Kojlo, Assessment of immobilized yeast for the separation and determination of platinum in environmental samples by flow-injection chemiluminescence and electrothermal atomic absorption spectrometry, Microchim. Acta 163 (2008) 327. [Pg.430]

Q.Z. Feng, L.X. Zhao, W. Yan, F. Ji, Y.L. Wei, J.M. Lin, Molecularly imprinted solid-phase extraction and flow-injection chemiluminescence for trace analysis of 2,4-dichlorophenol in water samples, Anal. Bioanal. Chem. 391 (2008) 1073. [Pg.445]

Y. Xiong, H.J. Zhou, Z.J. Zhang, D.Y. He, C. He, Molecularly imprinted on-line solid-phase extraction combined with flow-injection chemiluminescence for the determination of tetracycline, Analyst 131 (2006) 829. [Pg.446]

Fu, Z., Hao, C., Fei, X., and Ju, H. (2006) Flow injection chemiluminescent immunoassay for alpha fetoprotein based on epoxysilane modified glass microbeads. Journal of Immunological Methods, 312, 61 67. [Pg.379]

Lin, J., Yan, F., and Ju, H. (2004) Noncompetitive enzyme immunoassay for carcinoem bryonic antigen by flow injection chemiluminescence. Clinica Chimica Acta, 341, 109 115. [Pg.379]

Xiong Y, Zhou H, Zhang Z, He D, He C. Determination of hydralazine with flow injection chemiluminescence sensor using molecularly imprinted polymer as recognition element. J Pharm Biomed Anal 2006 41 694-700. [Pg.172]

Flow Injection Chemiluminescence Determination of Hydroxylamine Hydrochloride 175... [Pg.175]

Safavi A, Baezzat MR. Flow injection chemiluminescence determination of pyrogallol. Anal Chim Acta 1998 368 113-6. ... [Pg.176]

Wang L, Yang P, Li YX, Chen HQ, Li MG, Luo FB. A flow injection chemiluminescence method for the determination of fluoroquinolone derivative using the reaction of luminol and hydrogen peroxide catalyzed by gold nanoparticles. Talanta 2007 72 1066-72. [Pg.180]

Zhang YF, Cai XL, Yu JS, Ju HX. Flow injection chemiluminescence nalysis for highly sensitive determination of noscapine. Photochem Photobiol A Chem 2004 162 457-62. [Pg.212]


See other pages where Flow injection chemiluminescence is mentioned: [Pg.265]    [Pg.321]    [Pg.331]    [Pg.948]    [Pg.321]    [Pg.331]    [Pg.40]    [Pg.41]    [Pg.192]    [Pg.948]    [Pg.300]    [Pg.423]    [Pg.423]    [Pg.364]   
See also in sourсe #XX -- [ Pg.221 , Pg.257 , Pg.277 ]

See also in sourсe #XX -- [ Pg.348 ]




SEARCH



© 2024 chempedia.info