Is a system in place to identify, measure and control sources of error (blanks, duplicates, and rephcates) ... [Pg.29]

A proportional determinate error, in which the error s magnitude depends on the amount of sample, is more difficult to detect since the result of an analysis is independent of the amount of sample. Table 4.6 outlines an example showing the effect of a positive proportional error of 1.0% on the analysis of a sample that is 50.0% w/w in analyte. In terms of equations 4.4 and 4.5, the reagent blank, Sreag, is an example of a constant determinate error, and the sensitivity, k, may be affected by proportional errors. [Pg.61]

In a single-point standardization, we assume that the reagent blank (the first row in Table 5.1) corrects for all constant sources of determinate error. If this is not the case, then the value of k determined by a singlepoint standardization will have a determinate error. [Pg.117]

That all four methods give a different result for the concentration of analyte underscores the importance of choosing a proper blank but does not tell us which of the methods is correct. In fact, the variation within each method for the reported concentration of analyte indicates that none of these four methods has adequately corrected for the blank. Since the three samples were drawn from the same source, they must have the same true concentration of analyte. Since all four methods predict concentrations of analyte that are dependent on the size of the sample, we can conclude that none of these blank corrections has accounted for an underlying constant source of determinate error. [Pg.128]

To correct for all constant method errors, a blank must account for signals due to the reagents and solvent used in the analysis and any bias due to interac-... [Pg.128]

A reagent blank corrects the measured signal for signals due to reagents other than the sample that are used in an analysis. The most common reagent blank is prepared by omitting the sample. When a simple reagent blank does not compensate for all constant sources of determinate error, other types of blanks, such as the total Youden blank, can be used. [Pg.130]

Accuracy Under normal conditions relative errors of 1-5% are easily obtained with UV/Vis absorption. Accuracy is usually limited by the quality of the blank. Examples of the type of problems that may be encountered include the presence of particulates in a sample that scatter radiation and interferents that react with analytical reagents. In the latter case the interferant may react to form an absorbing species, giving rise to a positive determinate error. Interferents also may prevent the analyte from reacting, leading to a negative determinate error. With care, it maybe possible to improve the accuracy of an analysis by as much as an order of magnitude. [Pg.409]

In the process of performing a spectrophotometric determination of Ee, an analyst prepares a calibration curve using a single-beam spectrometer, such as a Spec-20. After preparing the calibration curve, the analyst drops the cuvette used for the method blank and the standards. The analyst acquires a new cuvette, measures the absorbance of the sample, and determines the %w/w Ee in the sample. Will the change in cuvette lead to a determinate error in the analysis Explain. [Pg.450]

Spike recoveries on method blanks and field blanks are used to evaluate the general performance of an analytical procedure. The concentration of analyte added to the blank should be between 5 and 50 times the method s detection limit. Systematic errors occurring during sampling and transport will result in an unacceptable recovery for the field blank, but not for the method blank. Systematic errors occurring in the laboratory, however, will affect the recoveries for both the field and method blanks. [Pg.711]

The first sample to be analyzed is the field blank. If its spike recovery is unacceptable, indicating that a systematic error is present, then a laboratory method blank. Dp, is prepared and analyzed. If the spike recovery for the method blank is also unsatisfactory, then the systematic error originated in the laboratory. An acceptable spike recovery for the method blank, however, indicates that the systematic error occurred in the field or during transport to the laboratory. Systematic errors in the laboratory can be corrected, and the analysis continued. Any systematic errors occurring in the field, however, cast uncertainty on the quality of the samples, making it necessary to collect new samples. [Pg.712]

The use of several QA/QC methods is described in this article, including control charts for monitoring the concentration of solutions of thiosulfate that have been prepared and stored with and without proper preservation the use of method blanks and standard samples to determine the presence of determinate error and to establish single-operator characteristics and the use of spiked samples and recoveries to identify the presence of determinate errors associated with collecting and analyzing samples. [Pg.722]

The analytical uncertainty should be reduced to one-third or less of sampling uncertainty (16). Poor results obtained because of reagent contamination, operator errors ia procedure or data handling, biased methods, and so on, can be controlled by proper use of blanks, standards, and reference samples. [Pg.241]

Separate sample blanking requires an additional analytical channel, and is therefore wasteflil of both reagents and hardware. An alternative approach that is used on several automated systems, eg, Du Pont ACA, BM-Hitachi 704, Technicon RA-1000, is that of bichromatic analysis (5) where absorbance measurements are taken at two, rather than one, wavelength. When the spectral curves for the interference material and the chromogen of the species measured differ sufficiently, this can be an effective technique for reducing blank contributions to assay error. Bichromatic analysis is effective for blanks of both the first and second type. [Pg.393]

Simple gravimetry of the sample is likely to be an integral component of the determination of, e.g., the concentration of, or exposures to, airborne dust. Care is required to avoid errors arising from absorption of atmospheric moisture. Tliis can be avoided by using blank filters, by conditioning the filters in an atmospherically-controlled room, or use of a desiccator. [Pg.312]

Maximum amount on-site left blank. In a surprising number of Forms, Part HI, Section 4 on page three of Form R is left blank. Leaving this section blank will result in a Notice of Technical Error. [Pg.91]

The titration error will increase with increasing dilution of the solution being titrated and is quite appreciable (ca 0.4 per cent) in dilute, say 0.01 M, solutions when the chromate concentration is of the order 0.003-0.005M. This is most simply allowed for by means of an indicator blank determination, e.g. by measuring the volume of standard silver nitrate solution required to give a perceptible coloration when added to distilled water containing the same quantity of indicator as is employed in the titration. This volume is subtracted from the volume of standard solution used. [Pg.344]

This method has the drawback that an excess of oxidising agent is always present at the end point. For work of the highest accuracy, the indicator blank may be determined and allowed for, or the error may be considerably reduced by performing the standardisation and determination under similar experimental conditions. [Pg.368]

It is crucial in quantitative GC to obtain a good separation of the components of interest. Although this is not critical when a mass spectrometer is used as the detector (because ions for identification can be mass selected), it is nevertheless good practice. If the GC effluent is split between the mass spectrometer and FID detector, either detector can be used for quantitation. Because the response for any individual compound will differ, it is necessary to obtain relative response factors for those compounds for which quantitation is needed. Care should be taken to prevent contamination of the sample with the reference standards. This is a major source of error in trace quantitative analysis. To prevent such contamination, a method blank should be run, following all steps in the method of preparation of a sample except the addition of the sample. To ensure that there is no contamination or carryover in the GC column or the ion source, the method blank should be run prior to each sample. [Pg.215]

Activation analysis is based on a principle different from that of other analytical techniques, and is subject to other types of systematic error. Although other analytical techniques can compete with NAA in terms of sensitivity, selectivity, and multi-element capability, its potential for blank-free, matrix-independent multielement determination makes it an excellent reference technique. NAA has been used for validation of XRF and TXRF. [Pg.664]

The ultrasound-assisted experiment of Figure 2(a) is again not typical in that the reagent concentrations have an inflection point mid-way through the reaction. We have performed a kinetic analyses of the stirred (blank) data in Figure 2(b) and found the following equations reproduce the data well with a root-mean-square error of 2.8% ... [Pg.308]


See other pages where Errors blank is mentioned: [Pg.426]    [Pg.426]    [Pg.496]    [Pg.47]    [Pg.58]    [Pg.95]    [Pg.96]    [Pg.104]    [Pg.107]    [Pg.129]    [Pg.179]    [Pg.354]    [Pg.683]    [Pg.710]    [Pg.710]    [Pg.775]    [Pg.811]    [Pg.108]    [Pg.256]    [Pg.91]    [Pg.341]    [Pg.193]    [Pg.54]    [Pg.48]    [Pg.619]    [Pg.304]    [Pg.355]    [Pg.204]    [Pg.101]   