To permit the location of life saving appliances, flammable liquid stores, radioactive and emergency control points in safe areas where practical. [Pg.144]

Determine Critical Control Points. A critical control point (CCP) is any point in the process where loss of control may result in an unacceptable health risk. A CCP is estabhshed for each identified hazard. The emergence of foodbome pathogens has taught food processors the importance of potential product contamination from the processing environment. [Pg.33]

The activation point should be mounted at a height which is convenient to personnel. The ergonomics of personnel access to emergency controls should be accommodated. [Pg.120]

While actin nucleation represents one key control point in determining the dynamic behavior of cellular actin networks, an equally important point of control is filament disassembly. Only by maintaining actin polymers in a state of rapid turnover can cells maintain a pool of assembly-competent actin subunits for new growth and reorganize their networks rapidly in response to signals. Replenishment of subunits is accelerated by cellular factors that selectively destabilize and depolymerize the older (ADP-bound) filaments in networks. Cofilin (also called ADF) plays a central role in this process and recendy it has emerged that coronin assists cofilin in driving these events. [Pg.81]

BXX Control Points/MMI BIX Control Rooms Main Control Room and Emergency Control Room... [Pg.146]

To facilitate workflow, the areas around an emergency incident are divided into three zones exclusion zone, contamination reduction zone (CRZ), and support zone (see Figure 18-3). The zones should be located upwind of the emergency site. To minimize spread of contamination, workers should not cross from one zone to another except at approved points, called access control points. [Pg.238]

Elevated storage reservoir shall be located centrally/near to as many process units as possible which need water always. The bottom outlet valve shall be operated by a solenoid control, and it shall open when power fails. It shall supply water to emergency use points such scmbbers, cooling jackets, electrode cooling, etc. [Pg.98]

Accident response for HCF activities is addressed In the TA-V Emergency Plan. In the event of an accident, all personnel evacuate to the Emergency Assembly Point, the Emergency Control Room, or the Emergency Response Team assembly area, depending on their assignments. [Pg.292]

Obviously, in industrial production of polymers and emulsions, there has been a lot of work done by manufacturers on their products. Usually, after a trial-and-error procedure with parameters such as speed and diameter of the impeller, there emerges a point at which the combination of aU the effects gives a drop-size distribution, yielding a product that is controllable and is useftil as an industrial process. Going down to the microsize, one finds guess involved in the limit of shear-rate properties that occur at the minimum scale, predicted by the Komolgarof equation. This equation is given as ... [Pg.369]

In addition, as appropriate for their functions, protective clothing, continuous communications, respiratory protection, and stable iodine tablets, if radioactive iodine may be present, should be provided to emergency workers. If the entry into contaminated areas is anticipated, an access control point should be established protective clothing, personal decontamination equipment (e.g., emergency showers), and spare clothing should be available. All the hazards possible while performing their response duties (e.g., toxic atmospheres) should be addressed. [Pg.146]

A widely developed grid of decentralized, silent, local power plants with a capacity of tens to hundreds of kilowatts for use as a power supply or as a combined power and heat supply in remote locations, buildings, or installations not hooked up to the grid, such as stations for meteorological and hydrological observation and for use as an emergency power supply in individual installations such as hospitals and control points... [Pg.5]

Incident or site-level coordination tends to occur close to the area of impact and focus of response, from what is usually referred to as an incident command post, incident control point, or similar. Incident management at this level is usually populated by low-level managers of the agencies contributing to the response and may include supervisors of field components of critical infrastructure providers. Despite this use of the term incident, the same term is often applied to all levels of emergency and disaster. [Pg.964]

The first priority is to establish control of the incident site and organise an appropriate command structure. This includes the establishment of a clearly marked location as an incident control point (ICP), sometimes referred to as the Joint Emergency Services Command Centre (JESCC), where the emergency services can meet to coordinate the response. In the case of a chemical incident this should be positioned upwind of fhe chemical release area and preferably in a hard-standing covered location. Specially designed mobile major incident rooms (MMIR) may be available. [Pg.240]

Fibers spun by this method may be isotropic or asymmetric, with dense or porous walls, depending on the dope composition. An isotropic porous membrane results from spinning solutions at the point of incipient gelation. The dope mixture comprises a polymer, a solvent, and a nonsolvent, which are spun into an evaporative column. Because of the rapid evaporation of the solvent component, the spinning dope solidifies almost immediately upon emergence from the spinneret in contact with the gas phase. The amount of time between the solution s exit from the spinneret and its entrance into the coagulation bath has been found to be a critical variable. Asymmetric fibers result from an inherently more compatible solvent/nonsolvent composition, ie, a composition containing lower nonsolvent concentrations. The nature of the exterior skin (dense or porous) of the fiber is also controlled by the dope composition. [Pg.149]

If control valves are used for emergency isolation, a special switch may be necessary, out on the plant, to close them in an emergency so that operators do not have to go to the control room to alter the set-points on the controllers. [Pg.156]


See other pages where Emergency control point is mentioned: [Pg.232]    [Pg.142]    [Pg.357]    [Pg.232]    [Pg.142]    [Pg.357]    [Pg.172]    [Pg.320]    [Pg.179]    [Pg.471]    [Pg.19]    [Pg.132]    [Pg.68]    [Pg.29]    [Pg.42]    [Pg.319]    [Pg.320]    [Pg.350]    [Pg.166]    [Pg.80]    [Pg.168]    [Pg.90]    [Pg.114]    [Pg.2898]    [Pg.490]    [Pg.389]    [Pg.380]    [Pg.530]    [Pg.226]    [Pg.1717]    [Pg.2299]    [Pg.2499]    [Pg.389]    [Pg.66]    [Pg.540]    [Pg.79]   