The AGDISP model is based on actually tracking the motion of discrete particles. The dynamic equations governing the particle trajectory are developed and integrated. The equations include the influence of the aircraft dispersal system configuration, aircraft wake turbulence, atmospheric turbulence, gravity, and evaporation. [Pg.82]

Disperse systems consist normally of two or more phases in which the continuous phases are intermixed. If, in a continuous phase (the dispersion medium), the elements of the disperse matter are embedded such that they can be individually distinguished, the system is called discretely disperse, A coherent disperse phase, which may also consist of well-defined elements adhering to or intermixed with each other, is called compact disperse. [Pg.2]

The simplest application of these multiplexing methods involves the so-called direct-reading spectrometer , which was used with some success for a short period in atomic spectroscopy [42]. This instrument consists of a dispersion system with an array of exit silts arranged at appropriate locations. Behind each silt Is a photodetector —usually a photomultiplier. These multiplexing methods have also been used In UV-vIsIble spectroscopy, although to a lesser extent they have been Implemented on automatic discrete analysers featuring an optical system of this type with 5-10 channels or wavelengths... [Pg.298]

Because of its inherent brittleness, polystyrene homopolymer itself has limited application in blends. However, its impact modified version, viz., HIPS, is more widely used. HIPS itself is a reactor-made multiphase system with 5 to 13% polybutadiene ( cis -rich) dispersed as discrete particles in the polystyrene phase, with an optimum particle size of mean diameter of 2.5 fim. The rubber in HIPS is chemically grafted to some extent to the polystyrene. The effective volume of... [Pg.1042]

Considering coagulation in poly-disperse systems, it is convenient to use the continuous particles distribution over volumes, rather than discrete distribution. If we assume that a distribution is homogeneous in suspension volume, then n= n(V,i), where V is the particle volume. In this case ndV is number of particles with volumes within the range (V, V + dV) in a unit volume of suspension. [Pg.291]

Probably the most widely used industrial emulsion or dispersion adhesives are those based on poly(vinyl acetate), commonly referred to as PVA. These product are normally manufactured by emulsion polymerization whereby, basically, vinyl acetate monomer is emulsified in water with a suitable colloid-emulsifier system, such as poly(vinyl alcohol) and sodium lauryl sulfate, and, with the use of water soluble initiator such as potassium persulfate, is polymerized. The polymerization takes place over a period of four hours at 70°C. Because the reaction is exothermic, provisions must be made for cooling when the batch size exceeds a few liters. The presence of surfactants (emulsifiers) and water-soluble protective colloids facilitates the process resulting in a stable dispersion of discrete polymer particles in the aqueous phase. [Pg.617]

The methodological background to obtaining the transport properties from discrete compartments is the formalism used by Cory and Garroway (50) to obtain the displacement profile (15) of molecules in a dispersed system. Detailed information on the mole cular motion may be obtained by measuring the A dependence of the apparent diffusion coefficient caused by a possible obstruction of the spin motion. The stimulated echo sequence, Fig. 9a, is usually used to probe various diffusion times, A. As is seen from the fig-... [Pg.289]

Inverse (or water-in-oil) emulsions (315, 401) are emulsions in which an aqueous phase is dispersed within a continuous organic phase. This system is essentially the inverse of a conventional emulsion, hence the name inverse emulsion. The organic phase is typically an inert hydrocarbon (such as mixed xylenes or low-odour kerosenes), and the aqueous phase contains a water-soluble monomer such as acrylamide (268). The aqueous phase may be dispersed as discrete droplets or as a bicontinuous phase (335), depending upon the formulation and conditions of the inverse emulsion. The hydrophilic-lipophilic balance (HLB) value of the stabiliser determines the form and stability of an inverse emulsion, with HLB values of less than 7 being appropriate for inverse emulsions. Steric stabilisers such as the Span , Tween , and Plutonic series of nonionic surfactants are usually used in preparing inverse emulsions. Inverse emulsions, suspensions, miniemulsions (199), and microemulsions have been prepared, primarily as a function of the stabiliser concentration. Commercial products produced by inverse emulsion polymerisation include polyacrylamide, a water-soluble polymer used extensively as a thickener. [Pg.9]

Phenolic Dispersions. These systems are predominantly resin-in-water systems in which the resin exists as discrete particles. Particle size ranges from 0.1 to 2 p.m for stable dispersions and up to 100 p.m for dispersions requiring constant agitation. Some of the earliest nonaqueous dispersions were developed for coatings appHcations. These systems consist of an oil-modified phenoHc resin complexed with a metal oxide and a weak solvent. [Pg.298]

Aqueous dispersions are alternatives to solutions of Hquid and soHd resins. They are usuaUy offered in 50% soHds and may contain thickeners and cosolvents as stabilizers and to promote coalescence. Both heat-reactive (resole) and nonheat-reactive (novolak) systems exist that contain unsubstituted or substituted phenols or mixtures. A related technology produces large, stable particles that can be isolated as discrete particles (44). In aqueous dispersion, the resin stmcture is designed to produce a hydrophobic polymer, which is stabilized in water by an interfacial agent. [Pg.303]

In a chromatographic separation, the individual components of a mixture are moved apart in the column due to their different affinities for the stationary phase and, as their dispersion is contained by appropriate system design, the individual solutes can be eluted discretely and resolution is achieved. Chromatography theory has been developed over the last half century, but the two critical theories, the Plate Theory and the Rate Theory, were both well established by 1960. There have been many contributors to chromatography theory over the intervening years but, with the... [Pg.16]

Recalling that a separation is achieved by moving the solute bands apart in the column and, at the same time, constraining their dispersion so that they are eluted discretely, it follows that the resolution of a pair of solutes is not successfully accomplished by merely selective retention. In addition, the column must be carefully designed to minimize solute band dispersion. Selective retention will be determined by the interactive nature of the two phases, but band dispersion is determined by the physical properties of the column and the manner in which it is constructed. It is, therefore, necessary to identify those properties that influence peak width and how they are related to other properties of the chromatographic system. This aspect of chromatography theory will be discussed in detail in Part 2 of this book. At this time, the theoretical development will be limited to obtaining a measure of the peak width, so that eventually the width can then be related both theoretically and experimentally to the pertinent column parameters. [Pg.179]

To reiterate the definition of chromatographic resolution a separation is achieved in a chromatographic system by moving the peaks apart and by constraining the peak dispersion so that the individual peaks can be eluted discretely. Thus, even if the column succeeds in meeting this criterion, the separation can still be destroyed if the peaks are dispersed in parts of the apparatus other than the column. It follows that extra-column dispersion must be controlled and minimized to ensure that the full performance of the column is realized. [Pg.287]

A satisfactory chromatographic analysis demands, a priori, on an adequate separation of the constituents of the sample that will permit the accurate quantitative evaluation of each component of interest. To achieve this, an appropriate phase system must be chosen so that the individual components of the mixture will be moved apart from one another in the column. In addition, their dispersion must be constrained sufficiently to allow all the solutes of interest to be eluted discretely. At this stage it is necessary to introduce the concept of the Reduced Chromatogram. [Pg.361]

At this point, it is important to stress the difference between separation and resolution. Although a pair of solutes may be separated they will only be resolved if the peaks are kept sufficiently narrow so that, having been moved apart (that is, separated), they are eluted discretely. Practically, this means that firstly there must be sufficient stationary phase in the column to move the peaks apart, and secondly, the column must be constructed so that the individual bands do not spread (disperse) to a greater extent than the phase system has separated them. It follows that the factors that determine peak dispersion must be identified and this requires an introduction to the Rate Theory. The Rate Theory will not be considered in detail as this subject has been treated extensively elsewhere (1), but the basic processes of band dispersion will be examined in order to understand... [Pg.93]

A colloid is defined as a system consisting of discrete particles in the size range of 1 nm to 1 pm, distributed within a continuous phase [153], On the basis of the interaction of particles, molecules, or ions of the disperse phase with molecules of the dispersion medium-, colloidal systems can be classified as being lyophilic or lyophobic. In lyophilic systems, the disperse phase molecules are dissolved within the continuous phase and in the colloidal size range or spontaneously form aggregates in the colloidal size range (association systems). In lyophobic systems, the disperse phase is very poorly soluble or insoluble in the continuous phase. During the last several decades, the use of colloids in... [Pg.273]


See other pages where Disperse systems discretely is mentioned: [Pg.154]    [Pg.81]    [Pg.288]    [Pg.1846]    [Pg.401]    [Pg.19]    [Pg.924]    [Pg.223]    [Pg.349]    [Pg.90]    [Pg.607]    [Pg.326]    [Pg.115]    [Pg.18]    [Pg.3]    [Pg.1023]    [Pg.84]    [Pg.1755]    [Pg.4]    [Pg.237]    [Pg.772]    [Pg.170]    [Pg.137]    [Pg.400]    [Pg.480]    [Pg.154]    [Pg.693]    [Pg.293]    [Pg.544]    [Pg.396]   