Detector counter

Connect the detector-counter apparatus by following the directions given by your teacher. Switch the apparatus on. [Pg.30]

It was found that that in the case of soft beta and X-ray radiation the IPs behave as an ideal gas counter with the 100% absorption efficiency if they are exposed in the middle of exposure range ( 10 to 10 photons/ pixel area) and that the relative uncertainty in measured intensity is determined primarily by the quantum fluctuations of the incident radiation (1). The thermal neutron absorption efficiency of the present available Gd doped IP-Neutron Detectors (IP-NDs) was found to be 53% and 69%, depending on the thicknes of the doped phosphor layer ( 85pm and 135 pm respectively). No substantial deviation in the IP response with the spatial variation over the surface of the IP was found, when irradiated by the homogeneous field of X-rays or neutrons and deviations were dominated by the incident radiation statistics (1). [Pg.507]

There are many types of electronic detector. The original fomi of electronic detector was the Geiger counter, but it was replaced many years ago by the proportional counter, which allows selection of radiation of a particular type or energy. Proportional counters for x-rays are filled witii a gas such as xenon, and those for... [Pg.1379]

Figure Bl.10.2. Schematic diagram of a counting experiment. The detector intercepts signals from the source. The output of the detector is amplified by a preamplifier and then shaped and amplified friitlier by an amplifier. The discriminator has variable lower and upper level tliresholds. If a signal from the amplifier exceeds tlie lower tlireshold while remaming below the upper tlireshold, a pulse is produced that can be registered by a preprogrammed counter. The contents of the counter can be periodically transferred to an online storage device for fiirther processing and analysis. The pulse shapes produced by each of the devices are shown schematically above tlieni. Figure Bl.10.2. Schematic diagram of a counting experiment. The detector intercepts signals from the source. The output of the detector is amplified by a preamplifier and then shaped and amplified friitlier by an amplifier. The discriminator has variable lower and upper level tliresholds. If a signal from the amplifier exceeds tlie lower tlireshold while remaming below the upper tlireshold, a pulse is produced that can be registered by a preprogrammed counter. The contents of the counter can be periodically transferred to an online storage device for fiirther processing and analysis. The pulse shapes produced by each of the devices are shown schematically above tlieni.
For either the in-line or hybrid analyzers, the ions injected into the TOF section must all begin their flight down the TOF tube at the same instant if arrival times of ions at a detector are to be used to measure m/z values (see Chapter 26, TOF Ion Optics ). For the hybrid TOF instruments, the ion detector is usually a microchannel plate ion counter (see Chapter 30, Comparison of Multipoint Collectors (Detectors) of Ions Arrays and MicroChannel Plates ). [Pg.153]

Figure 8.28 shows how the X-rays fall on the solid or liquid sample which then emits X-ray fluorescence in the region 0.2-20 A. The fluorescence is dispersed by a flat crystal, often of lithium fluoride, which acts as a diffraction grating (rather like the quartz crystal in the X-ray monochromator in Figure 8.3). The fluorescence may be detected by a scintillation counter, a semiconductor detector or a gas flow proportional detector in which the X-rays ionize a gas such as argon and the resulting ions are counted. Figure 8.28 shows how the X-rays fall on the solid or liquid sample which then emits X-ray fluorescence in the region 0.2-20 A. The fluorescence is dispersed by a flat crystal, often of lithium fluoride, which acts as a diffraction grating (rather like the quartz crystal in the X-ray monochromator in Figure 8.3). The fluorescence may be detected by a scintillation counter, a semiconductor detector or a gas flow proportional detector in which the X-rays ionize a gas such as argon and the resulting ions are counted.
Alpha counting is done with an internal proportional counter or a scintiUation counter. Beta counting is carried out with an internal or external proportional gas-flow chamber or an end-window Geiger-MueUer tube. The operating principles and descriptions of various counting instmments are available, as are techniques for determining various radioelements in aqueous solution (20,44). A laboratory manual of radiochemical procedures has been compiled for analysis of specific radionucHdes in drinking water (45). Detector efficiency should be deterrnined with commercially available sources of known activity. [Pg.233]

The cadmium chalcogenide semiconductors (qv) have found numerous appHcations ranging from rectifiers to photoconductive detectors in smoke alarms. Many Cd compounds, eg, sulfide, tungstate, selenide, teUuride, and oxide, are used as phosphors in luminescent screens and scintiUation counters. Glass colored with cadmium sulfoselenides is used as a color filter in spectroscopy and has recently attracted attention as a third-order, nonlinear optical switching material (see Nonlinear optical materials). DiaLkylcadmium compounds are polymerization catalysts for production of poly(vinyl chloride) (PVC), poly(vinyl acetate) (PVA), and poly(methyl methacrylate) (PMMA). Mixed with TiCl, they catalyze the polymerization of ethylene and propylene. [Pg.392]

Benchtop X-ray energy dispersive analyzer BRA-17-02 based on a gas-filled electroluminescent detector with an x-ray tube excitation and range of the elements to be determined from K (Z=19) to U (Z=92) an electroluminescent detector ensures two times better resolution compared with traditional proportional counters and possesses 20 times greater x-ray efficiency compared with semiconductor detectors. The device is used usually for grits concentration determination when analysing of aviation oils (certified analysis procedures are available) and in mining industry. [Pg.76]

XRD is an excellenr, nondestructive method for identifying phases and characterizing the structural properties of thin films and multilayers. It is inexpensive and easy to implement. The future will see more use of GIXD and depth dependent measurements, since these provide important information and can be carried out on lab-based equipment (rather than requiring synchrotron radiation). Position sensitive detectors will continue to replace counters and photographic film. [Pg.212]

Fig. 2-3. Number of electrons produced at various detector voltages for each x-ray quantum absorbed. A quantum of 1-A wavelength produces 400 ion pairs directly (solid line). A quantum of 10-A wavelength produces directly only 40 ion pairs (dotted line). (After Wilkinson, Ionization Chambers and Counters, University Press, Cambridge.)... Fig. 2-3. Number of electrons produced at various detector voltages for each x-ray quantum absorbed. A quantum of 1-A wavelength produces 400 ion pairs directly (solid line). A quantum of 10-A wavelength produces directly only 40 ion pairs (dotted line). (After Wilkinson, Ionization Chambers and Counters, University Press, Cambridge.)...
At present, the Geiger counter is the most popular x-ray detector in analytical chemistry. Although it is yielding ground to the proportional counter and the scintillation counter, it will be remembered for having greatly accelerated the use of x-ray emission spectrography in analytical chemistry. [Pg.52]

Because the Geiger counter produces pulses independent in size of x-ray wavelength, it is the best detector for the method of counting that employs a capacitor to accumulate the individual counts (2.3, 2.10). [Pg.52]

Intensity measurements are simplified when a detector always gives one electrical pulse for each x-ray quantum absorbed the detector remains linear so long as this is true. For low intensities, when the rates of incidence upon the detector are low, the Geiger counter fulfills this condition. As this rate increases above (about) 500 counts per second, the number of pulses per second decreases progressively below the number of quanta absorbed per second. This decrease occurs even with electronic circuits that can handle higher counting rates without appreciable losses. [Pg.52]

The cause of this difficulty therefore resides within the counter itself. The difficulty is described by saying that the Geiger counter has a dead time, by which is meant the time interval after a pulse during which the counter cannot respond to a later pulse. This interval, which is usually well below 0.5 millisecond, limits the useful maximum counting rate of the detector. The cause of the dead time is the slowness with which the positive-ion space charge (2.5) leaves the central wire under the influence of the electric field. This reduction in observed counting rate is known as the coincidence loss. [Pg.52]

In all this early work, the x-ray beam impinged upon a phosphor powder on the tube envelope. Detectors of this general kind will be called phosphor-photoelectric detectors to distinguish them from modern scintillation counters (2.11), also photoelectric, in which the light is often generated in a single crystal. The name phosphor-photoelectric detector/ though necessary, is clumsy and not entirely satisfactory. [Pg.58]

In the phosphor-photoelectric detector used as just described, the x-ray quanta strike the phosphor at a rate so great that the quanta of visible light are never resolved they are integrated into a beam of visible light the intensity of which is measured by the multiplier phototube. In the scintillation counters usual in analytical chemistry, on the other hand, individual x-ray quanta can be absorbed by a single crystal highly transparent to light (for example, an alkali halide crystal with thallium as activator), and the resultant visible scintillations can produce an output pulse of electrons from the multiplier phototube. The pulses can be counted as were the pulses-from the proportional counter. [Pg.59]


See other pages where Detector counter is mentioned: [Pg.29]    [Pg.55]    [Pg.39]    [Pg.4]    [Pg.158]    [Pg.29]    [Pg.55]    [Pg.39]    [Pg.4]    [Pg.158]    [Pg.402]    [Pg.1060]    [Pg.1420]    [Pg.1427]    [Pg.643]    [Pg.644]    [Pg.224]    [Pg.9]    [Pg.443]    [Pg.15]    [Pg.23]    [Pg.420]    [Pg.422]    [Pg.482]    [Pg.190]    [Pg.320]    [Pg.15]    [Pg.203]    [Pg.341]    [Pg.174]    [Pg.1291]    [Pg.218]    [Pg.69]    [Pg.49]    [Pg.53]    [Pg.53]    [Pg.56]   
See also in sourсe #XX -- [ Pg.32 , Pg.67 , Pg.68 , Pg.71 , Pg.75 , Pg.80 , Pg.134 ]




SEARCH



Counter-flow leak detector

Detector scintillation counter

Detector types scintillation counter

Detectors radiation counters

Detectors true counters

Geiger Muller counter (particle detector

Proportional counter detector