Detection atomic absorption spectroscopy

There are five main techniques of analysis that have been used to determine dissolved manganese inductively coupled plasma (ICP) (using both emission spectroscopy and mass spectrometry detection), atomic absorption spectroscopy (AAS) (using both flame and furnace atomization), electronic spectroscopy (colorimetry), electron paramagnetic resonance spectroscopy (EPR), and anodic stripping voltammetry (ASV). [Pg.475]

An immunoassay is the indirect assay of an analyte whose concentration in a matrix (blood, plasma, urine, drinking water, etc.) is at most several micrograms/ litre. It is based on the specific interaction between three components (Fig. 8.1) the analyte (antigen) to be assayed, a specific (polyclonal or monodonal) antibody of the analyte, plus a tracer consisting of the analyte (antigen) or the antibody, modified by addition of a label that can be detected at the nanomolar (or better, at the picomolar) level by an analytical technique such as radioactivity, enzymatic detection, electrochemical detection, atomic absorption spectroscopy (AAS), Fourier-transform infrared (FT-IR) spectroscopy, or fluorescence polarization (FP). [Pg.264]

The section on Spectroscopy has been expanded to include ultraviolet-visible spectroscopy, fluorescence, Raman spectroscopy, and mass spectroscopy. Retained sections have been thoroughly revised in particular, the tables on electronic emission and atomic absorption spectroscopy, nuclear magnetic resonance, and infrared spectroscopy. Detection limits are listed for the elements when using flame emission, flame atomic absorption, electrothermal atomic absorption, argon ICP, and flame atomic fluorescence. Nuclear magnetic resonance embraces tables for the nuclear properties of the elements, proton chemical shifts and coupling constants, and similar material for carbon-13, boron-11, nitrogen-15, fluorine-19, silicon-29, and phosphorus-31. [Pg.1287]

Detector Detection in FIA may be accomplished using many of the electrochemical and optical detectors used in ITPLC. These detectors were discussed in Chapter 12 and are not considered further in this section. In addition, FIA detectors also have been designed around the use of ion-selective electrodes and atomic absorption spectroscopy. [Pg.652]

Atomic absorption spectroscopy is more suited to samples where the number of metals is small, because it is essentially a single-element technique. The conventional air—acetylene flame is used for most metals however, elements that form refractory compounds, eg, Al, Si, V, etc, require the hotter nitrous oxide—acetylene flame. The use of a graphite furnace provides detection limits much lower than either of the flames. A cold-vapor-generation technique combined with atomic absorption is considered the most suitable method for mercury analysis (34). [Pg.232]

Atomic absorption spectroscopy is an alternative to the colorimetric method. Arsine is stiU generated but is purged into a heated open-end tube furnace or an argon—hydrogen flame for atomi2ation of the arsenic and measurement. Arsenic can also be measured by direct sample injection into the graphite furnace. The detection limit with the air—acetylene flame is too high to be useful for most water analysis. [Pg.232]

Atomic absorption spectroscopy of VPD solutions (VPD-AAS) and instrumental neutron activation analysis (INAA) offer similar detection limits for metallic impurities with silicon substrates. The main advantage of TXRF, compared to VPD-AAS, is its multielement capability AAS is a sequential technique that requires a specific lamp to detect each element. Furthermore, the problem of blank values is of little importance with TXRF because no handling of the analytical solution is involved. On the other hand, adequately sensitive detection of sodium is possible only by using VPD-AAS. INAA is basically a bulk analysis technique, while TXRF is sensitive only to the surface. In addition, TXRF is fast, with an typical analysis time of 1000 s turn-around times for INAA are on the order of weeks. Gallium arsenide surfaces can be analyzed neither by AAS nor by INAA. [Pg.355]

The strong selectivity of A A -dialkyl A-benzoylthiourea toward platinum metals has been favorably exploited to determine noble metals (Rh, Pd, Pt, and Au) in samples of ore and rocks by graphite fnmace atomic absorption spectroscopy (GFAAS) and UV detection after liquid chromatographic separation on silica HPTLC plates [23]. The results are presented in Table 14.3. [Pg.358]

AAS = atomic absorption spectroscopy CdS04 = cadmium sulfate GC/ECD = electrochemical gas chromatographic detection GC/FPD = gas chromatography with flame photometric detection HC1 = hydrochloric acid H2S = hydrogen sulfide NaOH = sodium hydroxide NR = not reported PAS = photoacoustic spectroscopy... [Pg.162]

Mullins [ 189] has described a procedure for determining the concentrations of dissolved chromium species in seawater. Chromium (III) and chromium (VI) separated by coprecipitation with hydrated iron (III) oxide and total dissolved chromium are determined separately by conversion to chromium (VI), extraction with ammonium pyrrolidine diethyl dithiocarbamate into methyl isobutyl ketone, and determination by atomic absorption spectroscopy. The detection limit is 40 ng/1 Cr. The dissolved chromium not amenable to separation and direct extraction is calculated by difference. In the waters investigated, total concentrations were relatively high, (1-5 pg/1), with chromium (VI) the predominant species in all areas sampled with one exception, where organically bound chromium was the major species. [Pg.161]

In contrast, the coupling of electrochemical and spectroscopic techniques, e.g., electrodeposition of a metal followed by detection by atomic absorption spectrometry, has received limited attention. Wire filaments, graphite rods, pyrolytic graphite tubes, and hanging drop mercury electrodes have been tested [383-394] for electrochemical preconcentration of the analyte to be determined by atomic absorption spectroscopy. However, these ex situ preconcentration methods are often characterised by unavoidable irreproducibility, contaminations arising from handling of the support, and detection limits unsuitable for lead detection at sub-ppb levels. [Pg.186]

Petit [563] has described a method for the determination of tellurium in seawater at picomolar concentrations. Tellurium (VI) was reduced to tellurium (IV) by boiling in 3 M hydrochloric acid. After preconcentration by coprecipitation with magnesium hydroxide, tellurium was reduced to the hydride by sodium borohydrate at 300 °C for 120 seconds, then 257 °C for 12 seconds. The hydride was then measured by atomic absorption spectroscopy. Recovery was 90 - 95% and the detection limit was 0.5 pmol/1. [Pg.222]

Agemian and Chau [55] have described an automated method for the determination of total dissolved mercury in fresh and saline waters by ultraviolet digestion and cold vapour atomic absorption spectroscopy. A flow-through ultraviolet digester is used to carry out photo-oxidation in the automated cold vapour atomic absorption spectrometric system. This removes the chloride interference. Work was carried out to check the ability of the technique to degrade seven particular organomercury compounds. The precision of the method at levels of 0.07 pg/1, 0.28 pg/1, and 0.55 pg/1 Hg was 6.0%, 3.8%, and 1.00%, respectively. The detection limit of the system is 0.02 pg/1. [Pg.463]

Limit of detection The method you choose must be able to detect the analyte at a concentration relevant to the problem. If the Co level of interest to the Bulging Drums was between 1 and 10 parts per trillion, would flame atomic absorption spectroscopy be the best method to use As you consider methods and published detection limits (LOD), remember that the LOD definition is the analyte concentration producing a signal that is three times the noise level of the blank, i.e., a S/N of 3. For real-world analysis, you will need to be at a level well above the LOD. Keep in mind that the LOD for the overall analytical method is often very different than the LOD for the instrumental analysis. [Pg.816]

High-performance liquid chromatography coupled with fluorescence detection [106, 107] or ion-exchange high-performance liquid chromatography with detection by graphite furnace atomic absorption spectroscopy [108] proved to be sensitive methods, but may lack from limitations in separation power and ease of identification of unknown products. [Pg.420]

The potential applications of NIR OFCD determination of metal ions are numerous. The detection of metal contaminants can be accomplished in real-time by using a portable fiber optical metal sensor (OFMD). Metal probe applications developed in the laboratory can be directly transferred to portable environmental applications with minimal effort. The response time of the NIR probe is comparable to its visible counterparts and is much faster than the traditional methods of metal analysis such as atomic absorption spectroscopy, polarography, and ion chromatography. With the use of OFMD results can be monitored on-site resulting in a significant reduction in labor cost and analysis time. [Pg.209]

The major anions and cations in seawater have a significant influence on most analytical protocols used to determine trace metals at low concentrations, so production of reference materials in seawater is absolutely essential. The major ions interfere strongly with metal analysis using graphite furnace atomic absorption spectroscopy (GFAAS) and inductively coupled plasma mass spectroscopy (ICP-MS) and must be eliminated. Consequently, preconcentration techniques used to lower detection limits must also exclude these elements. Techniques based on solvent extraction of hydrophobic chelates and column preconcentration using Chelex 100 achieve these objectives and have been widely used with GFAAS. [Pg.50]


See other pages where Detection atomic absorption spectroscopy is mentioned: [Pg.904]    [Pg.904]    [Pg.45]    [Pg.524]    [Pg.393]    [Pg.410]    [Pg.52]    [Pg.86]    [Pg.2]    [Pg.61]    [Pg.234]    [Pg.463]    [Pg.183]    [Pg.225]    [Pg.60]    [Pg.72]    [Pg.156]    [Pg.231]    [Pg.402]    [Pg.95]    [Pg.1380]    [Pg.805]    [Pg.47]    [Pg.25]    [Pg.387]    [Pg.299]    [Pg.541]    [Pg.31]    [Pg.276]    [Pg.319]    [Pg.183]    [Pg.345]    [Pg.76]   
See also in sourсe #XX -- [ Pg.677 ]




SEARCH



Atomic absorption spectroscopy

Atomic absorption spectroscopy detection limit

Atomic spectroscopy

Detection atomic

Detection atomic spectroscopy

Detection spectroscopy

© 2024 chempedia.info