Optical detectors can routinely measure only intensities (proportional to the square of the electric field), whether of optical pulses, CW beams or quasi-CW beams the latter signifying conditions where the pulse train has an interval between pulses which is much shorter than the response time of the detector. It is clear that experiments must be designed in such a way that pump-induced changes in the sample cause changes in the intensify of the probe pulse or beam. It may happen, for example, that the absorjDtion coefficient of the sample is affected by the pump pulse. In other words, due to the pump pulse the transparency of the sample becomes larger or smaller compared with the unperturbed sample. Let us stress that even when the optical density (OD) of the sample is large, let us say OD 1, and the pump-induced change is relatively weak, say 10 , it is the latter that carries positive infonnation. [Pg.3028]

Detector Detection in FIA may be accomplished using many of the electrochemical and optical detectors used in ITPLC. These detectors were discussed in Chapter 12 and are not considered further in this section. In addition, FIA detectors also have been designed around the use of ion-selective electrodes and atomic absorption spectroscopy. [Pg.652]

An optical detector with appropriate electronics and readout. Photomultiplier tubes supply good sensitivity for wavelengths in the visible range, and Ge, Si, or other photodiodes can be used in the near infrared range. Multichannel detectors like CCD or photodiode arrays can reduce measurement times, and a streak camera or nonlinear optical techniques can be used to record ps or sub-ps transients. [Pg.383]

Limited temporal resolution - Focal plane arrays are aU inherently framing detectors and knowledge of the arrival time of photons is limited to the frame time of the detector. While the frame time can be quite short for adaptive optics detectors ( 1 ms), in most astronomical instruments the frame time is on the order of seconds or minutes, adequate for most astronomical science, but not all. [Pg.127]

In comparison to infrared detectors, it is much more difficult for silicon-based optical detectors to achieve high QE over a wide bandpass. The main challenge is the tremendous variation of absorption depth shown in Fig. 8. In addition, the index of refraction varies significantly for A = 0.32-1.1 m, as shown in Fig. 10, making it difficult to optimize anti-reflection coatings for broad bandpass. [Pg.138]

P. Amico and J. W. Beletic eds., Optical Detectors for Astronomy II, state-of-the-art at the turn of the millenium, ASSL Series, Kluwer Academic Publisher, Dordrecht, 2000. [Pg.152]

Interferometric gravitational wave detectors 3.1 Properties of real optical detectors... [Pg.316]

Detection in SFC can be achieved in the condensed phase using optical detectors similar to those used in liquid chromatography or in the gas phase using detectors similar to those used in gas chromatography. Spectroscopic detectors, such as mass spectrometry and Fourier transform infrared spectroscopy, are relatively easily interfaced to SFC compared to the problems observed with liquid mobile phases (see Chapter 9). The range of available detectors for SFC is considered one of its strengths. [Pg.837]

Advanced computerisation and sensorisation and developments in the field of multielement optical detectors (CCD and PDA) and fibre optic remote spectroscopy have added modularity and flexibility. Silica-silica fibres used for spectroscopy applications are multimode with core diameters from 50 to 1000 p,m. The application of new technologies to optical instrumentation (e.g. improved gratings in spectrographs, the use of... [Pg.301]

In the above-described measurement, which we call the absolute method, all pumps have equal speeds (rpm) owing to interconnection to the same drive-shaft. In order to express, if required, a deviation registered for the analyte concentration, one must calibrate with a standard by varying its rpm (B) with respect to that of the titrant (A) a B/A rpm ratio greater than unity means a proportionally lower concentration and vice versa. In general, the absolute method serves to control a sample stream with nearly constant analyte concentration as a sensor one uses not only electroanalytical but often also optical detectors. However, with considerably varying analyte concentrations the differential method is more attractive its principle is that in the set-up in Fig. 5.15 and with the sensor adjusted to a fixed and most sensitive set-point, the rpm of the sample stream (C) is varied with respect to that of the titrant (A) by a feedback control (see Fig. 5.3a) from the sensor via a regulator towards the... [Pg.346]

As a development of experience with the RA-1000 instrument, Technicon recently introduced their most advanced Chem 1 capsule chemistry system. It consists of a one-channel CFA with a capacity of 1800 tests per hour and provided with eight sequential optical detectors along its pathway, which... [Pg.355]

Topics which will be presented in this chapter include the hardware, software, automation, valve and column configurations, and integration used in comprehensive 2DLC. Aspects of the 2DLC experiment in conjunction with multichannel detectors such as UV diode array optical detectors and mass spectrometers are discussed along with the handling of the data, which is expected to expand in scope in the future as chemometric methods are more widely used for data analysis. [Pg.97]

For example, the light emitted by a faint source may be chopped by means of a chopper producing a square wave-shaped light signal on an optical detector (see Fig. 10.8). Other spurious optical signals which are not modulated at the frequency of the chopper, as we... [Pg.247]

Optical detectors shall be used in more open configurations where ressure buildup due to the incipient explosion is limited. Optical etectors shall not be used where high dust concentrations limit the reliability of the suppression system. Both uv and ir detectors are available for optical detection. The use of daylight-sensitive sensors shall be avoided to avoid spurious activation. The sensor shall be mounted such that the angle of vision allows it to cover all the protected hazard area. The performance of an optical detector will also be affected by any obstacles within its vision, and this shall be overcome by the introduction of more detectors. Optical detectors shall be fitted with air shields to keep the optical lens clean. [Pg.19]

There are six types of optical detector commonly used in the oil and gas industry. [Pg.180]

Detectors with complete black body rejection capability are usually less sensitive to fires than a single frequency infrared optical detector. Because it s discrimination of fire and non-fire sources depend upon an analysis of the ratio between fire and reference frequencies, there is a variation in the amount of black body rejection achieved. A detector s degree of black body radiation rejection is in inversely proportion to its ability to sense a fire. The detectors are limited to applications that involve hydrocarbon materials. [Pg.182]

Optical data storage, high throughput experimentation, 7 414t Optical density measurements, 19 221 Optical detectors, gas chromatography,... [Pg.649]


See other pages where Detectors, optical is mentioned: [Pg.2873]    [Pg.68]    [Pg.536]    [Pg.394]    [Pg.402]    [Pg.2331]    [Pg.1169]    [Pg.38]    [Pg.69]    [Pg.129]    [Pg.137]    [Pg.138]    [Pg.25]    [Pg.191]    [Pg.148]    [Pg.319]    [Pg.321]    [Pg.324]    [Pg.637]    [Pg.211]    [Pg.471]    [Pg.360]    [Pg.461]    [Pg.464]    [Pg.505]    [Pg.508]    [Pg.11]    [Pg.439]    [Pg.183]    [Pg.120]    [Pg.75]    [Pg.89]    [Pg.245]   
See also in sourсe #XX -- [ Pg.180 ]

See also in sourсe #XX -- [ Pg.126 , Pg.127 , Pg.128 , Pg.129 , Pg.130 , Pg.131 , Pg.132 , Pg.133 , Pg.134 , Pg.135 , Pg.136 , Pg.137 , Pg.138 , Pg.139 ]

See also in sourсe #XX -- [ Pg.660 ]

See also in sourсe #XX -- [ Pg.115 ]

See also in sourсe #XX -- [ Pg.460 ]

See also in sourсe #XX -- [ Pg.282 , Pg.283 ]




SEARCH



© 2024 chempedia.info