Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Corrosion laboratory testing

Another commonly used cyclic corrosion laboratory test is GM9540P, Accelerated Corrosion Test [22]. The operating conditions are as follows ... [Pg.137]

Formulation of effective corrosion-resistant coatings is made difficult by the lack of a laboratory test that can provide rehable predictions of field performance. The most widely used test is exposure in a salt fog chamber. It has been shown repeatedly, however, that the results of such tests do not correlate with actual performance (125). Outdoor exposure of panels can provide useful data, especially in locations where salt spray occurs, but predictions of performance are not always satisfactory (126). [Pg.350]

Metals and alloys do not respond alike to aU the influences of the many factors that are involved in corrosion. Consequently, it is impractical to establish any universal standard laboratoiy procedures for corrosion testing except for inspection tests. However, some details of laboratory testing need careful attention in order to achieve useful results. [Pg.2425]

Duration of Test Although the duration of any test will be determined by the nature and purpose of the test, an excellent procedure for evaluating the effect or time on corrosion of the metal and also on the corrosiveness of the environment in laboratory tests has been presented by Wachter and Treseder [Chem. Eng. Pi og., 315-326 (June 1947)]. This technique is called the planned-interval test. Other procedures that require the removal of sohd corrosion products between exposure periods will not measure accurately the normal changes of corrosion with time. [Pg.2427]

Another difficulty sometimes encountered in laboratory tests is that contamination of the testing solution by corrosion products may change its corrosive nature to an appreciable extent. [Pg.2438]

Heat Flux Tests Removable tube test heat exchangers find an ideal use in the field for monitoring heat flux (corrosion) conditions, NACE TM0286-94 (similar to laboratory test. Fig. 28-4, page 28-12). [Pg.2440]

Evidence of localized corrosion can be obtained from polarization methods such as potentiodynamic polarization, EIS, and electrochemical noise measurements, which are particularly well suited to providing data on localized corrosion. When evidence of localized attack is obtained, the engineer needs to perform a careful analysis of the conditions that may lead to such attack. Correlation with process conditions can provide additional data about the susceptibility of the equipment to locaHzed attack and can potentially help prevent failures due to pitting or crevice corrosion. Since pitting may have a delayed initiation phase, careful consideration of the cause of the localized attack is critical. Laboratory testing and involvement of an... [Pg.2441]

Choices of alternative materials. Corrosion probes are carefully chosen to be as close as possible to the alloy composition, heat treatment, and stress condition of the material that is being monitored. Care must be taken to ensure that the environment at the probe matches the service environment. Choices of other alloys or heat treatments and other conditions must be made by comparison. Laboratory testing or coupon testing in the process stream can be used to examine alternatives to the current material, but the probes and the monitors can only provide information about the conditions which are present during the test exposure and cannot extrapolate beyond those conditions. [Pg.2441]

Materials evaluation should be based only on actual data obtained at conditions as close as possible to intended operating environments. Prediction of a material s performance is most accurate when standard corrosion testing is done in the actual service environment. Often it is extremely difficult in laboratory testing to expose a material to all of the impurities that the apparatus actually will contact. In addition, not all operating characteristics are readily simulated in laboratory testing. Nevertheless, there are standard laboratory practices that enable engineering estimates of the corrosion resistance of materials to be evaluated. [Pg.18]

Table 3.51 Corrosion of Type I Ni-Resist and ferritic cast iron in acetic acid in laboratory tests at 15°C... Table 3.51 Corrosion of Type I Ni-Resist and ferritic cast iron in acetic acid in laboratory tests at 15°C...
In laboratory tests Vernon showed that the relative humidity and the presence of sulphur dioxide have a profound effect on the rate of corrosion of copper, as of many other metals. When the relative humidity was less than 63%, there was little attack even in the presence of much sulphur dioxide, but when the relative humidity was raised to 75%, corrosion became severe and increased with the concentration of sulphur dioxide present. [Pg.689]

Oxidation tests on Nimonic 90A, in which sodium chloride was introduced into the atmosphere, showed that this constituent produces a significant deterioration in the protective nature of the normally adherent film. Although under certain service conditions the presence of sodium chloride is likely, this is not always so, and thus the general applicability of the results of laboratory tests in sodium sulphate and mixtures involving sodium chloride may be questioned. Test procedures for hot-salt corrosion have been reviewed by Saunders and Nicholls who concluded that burner rig testing is the most appropriate procedure provided contaminant flux rates similar to those found in an operating turbine are used in the rig. [Pg.1069]

It may be felt that the initiation of a stress-corrosion test involves no more than bringing the environment into contact with the specimen in which a stress is generated, but the order in which these steps are carried out may influence the results obtained, as may certain other actions at the start of the test. Thus, in outdoor exposure tests the time of the year at which the test is initiated can have a marked effect upon the time to failure as can the orientation of the specimen, i.e. according to whether the tension surface in bend specimens is horizontal upwards or downwards or at some other angle. But even in laboratory tests, the time at which the stress is applied in relation to the time at which the specimen is exposed to the environment may influence results. Figure 8.100 shows the effects of exposure for 3 h at the applied stress before the solution was introduced to the cell, upon the failure of a magnesium alloy immersed in a chromate-chloride solution. Clearly such prior creep extends the lifetime of specimens and raises the threshold stress very considerably and since other metals are known to be strain-rate sensitive in their cracking response, it is likely that the type of result apparent in Fig. 8.100 is more widely applicable. [Pg.1378]

The influence of moisture is fundamental, as it is with other forms of corrosion. Long-term contact tests with ponderosa pine, some treated with zinc chloride, in atmospheres at 30, 65 and 95% r.h. showed that at 30 and 65% r.h. plain wire nails were not very severely corroded even in zinc chloride-impregnated wood. At 95% r.h. plain wire nails were severely corroded, though galvanised nails were attacked only by impregnated wood. Brass and aluminium were also attacked to some extent at 95% r.h. Some concurrent outdoor tests at Madison, Wisconsin, showed that the outdoor climate there was somewhat more severe than a 65% r.h. laboratory test. [Pg.967]

Laboratory tests, although often necessarily conducted under conditions that are not met in service, nevertheless have a number of advantages over the other types of tests. Because conditions can be controlled at will it is possible to identify the separate effects of a number of factors on the corrosion behaviour. These factors include the type and condition of the metal surface, the environmental composition, temperature and pressure, movement of the specimen relative to the environment, time of exposure and so on. Laboratory tests, at least in principle, also enable comparisons to be made under identical conditions of the relative corrosion behaviour of... [Pg.977]

The duration of a particular test is likely to be determined by practical factors such as the need for some information within a particular limit of time, or the nature of the operation or process with which the test is concerned. Tests are rarely run too long however, this can happen, particularly in laboratory tests where the nature of the corrosive environment may be changed drastically by the exhaustion of some important constituent initially present in small concentration, or by the accumulation of reaction products that may either stifle or accelerate further attack. In either case, the corrosivity of the environment may be altered considerably. Gross errors may result from the assumption that the results apply to the original conditions of the test rather than to some uncertain and continually changing conditions that may exist during the course of too extended a test period. [Pg.983]

A similar method of test was used at the International Nickel Company s Corrosion Laboratory at North Carolina. The specimen discs are mounted on insulated vertical spindles and submerged in sea-water, which is supplied continuously to the tank in which the specimens are immersed. The maximum peripheral speed of the spinning disc is about 760cms , and the characteristic pattern of attack is shown in Fig. 19.3a. Studies of variation of depth of attack with velocity indicate that at low velocities (up to about 450 cm s ) alloys such as Admiralty brass, Cu-lONi and cupro-nickel alloys containing iron maintain their protective film with a consequent small and similar depth of attack for the diflferent alloys. At higher velocities the rate increases due to breakdown of the film. [Pg.996]


See other pages where Corrosion laboratory testing is mentioned: [Pg.258]    [Pg.266]    [Pg.294]    [Pg.349]    [Pg.2415]    [Pg.2423]    [Pg.2425]    [Pg.138]    [Pg.299]    [Pg.302]    [Pg.311]    [Pg.387]    [Pg.542]    [Pg.554]    [Pg.783]    [Pg.855]    [Pg.952]    [Pg.1024]    [Pg.1035]    [Pg.1072]    [Pg.1167]    [Pg.1191]    [Pg.1246]    [Pg.1271]    [Pg.1335]    [Pg.1365]    [Pg.1365]    [Pg.1366]    [Pg.1377]    [Pg.99]    [Pg.773]    [Pg.792]    [Pg.797]   


SEARCH



Corrosion corrosivity tests

Corrosion testing

Corrosion testing continued laboratory methods

Corrosion tests

Corrosivity test

Laboratory immersion corrosion testing

Laboratory immersion corrosion testing metals (ASTM

Laboratory testing

Laboratory tests corrosion

Laboratory tests corrosion

Testing Laboratory Tests

© 2024 chempedia.info