Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Control with limited measurements

When designing and evaluating an analytical method, we usually make three separate considerations of experimental error. First, before beginning an analysis, errors associated with each measurement are evaluated to ensure that their cumulative effect will not limit the utility of the analysis. Errors known or believed to affect the result can then be minimized. Second, during the analysis the measurement process is monitored, ensuring that it remains under control. Finally, at the end of the analysis the quality of the measurements and the result are evaluated and compared with the original design criteria. This chapter is an introduction to the sources and evaluation of errors in analytical measurements, the effect of measurement error on the result of an analysis, and the statistical analysis of data. [Pg.53]

Where large samples of reactant are used and/or where C02 withdrawal is not rapid or complete, the rates of calcite decomposition can be controlled by the rate of heat transfer [748] or C02 removal [749], Draper [748] has shown that the shapes of a—time curves can be altered by varying the reactant geometry and supply of heat to the reactant mass. Under the conditions used, heat flow, rather than product escape, was identified as rate-limiting. Using large ( 100 g) samples, Hills [749] concluded that the reaction rate was controlled by both the diffusion of heat to the interface and C02 from it. The proposed models were consistent with independently measured values of the transport parameters [750—752] whether these results are transfenable to small samples is questionable. [Pg.171]

The character and the degree of automation in chemical control may have been covered in the above treatment of semi-automatic or completely automatic, and of discontinuous or continuous analysis, but something more should be said about the means by which automation proper has been performed in recent times. Whereas in the past automated analysis involved the use of merely, mechanical robots, to-day s automation is preferably based on computerization in a way which can best be explained with a few specific examples. Adjustment knobs have been increasingly replaced with push-buttons that activate an enclosed fully dedicated microcomputer or microprocessor in line with the measuring instrument the term microcomputer is applicable if, apart from the microprocessor as the central processing unit (CPU), it contains additional, albeit limited, memory (e.g., 4K), control logics and input and output lines, by means of which it can act as satellite of a larger computer system (e.g., in laboratory computerization) if not enclosed, the microcomputer is called on-line. [Pg.327]

In the EU, the current chemical control measures, based on a network of legislation for hazard communication and safety assessment, are soon to be dramatically revised. To set the scene for this forthcoming fundamental change to chemical control in the EU, the key facets of the existing measures are described briefly i.e., notification of new chemical substances, the relatively-limited measures to evaluate existing substances and hazard communication. There have been problems with the current scheme, principally the disparity between the safety data on new and existing substances. [Pg.3]

The modest electrical drive requbements of these diodes, and the resulting option to power the laser with standard penlight (AA) batteries, allow these CnLiSAF lasers to boast an impressive electrical-to-optical efficiency of over 4 %, which until recently" was the highest reported overall system efficiency of any femtosecond laser source. The amplitude stability of the laser output was observed to be very stable with a measured fluctuation of less than 1% for periods in excess of 1 h. These measurements were made on a laser that was not enclosed and located in a lab that was not temperature-controlled. In a more enclosed and conbolled local envbonment we would expect the amplitude fluctuations of this laser to be extremely small. While the output powers achievable from these lasers have been limited by the available power from the AlGalnP red laser pump diodes, there are already sbong indications that commercial access to higher-power suitable diode lasers is imminent. [Pg.210]

For the catalytic electrode mechanism, the total surface concentration of R plus O is conserved throughout the voltammetric experiment. As a consequence, the position and width of the net response are constant over entire range of values of the parameter e. Figure 2.35 shows that the net peak current increases without limit with e. This means that the maximal catalytic effect in particular experiment is obtained at lowest frequencies. Figure 2.36 illustrates the effect of the chemical reaction on the shape of the response. For log(e) < -3, the response is identical as for the simple reversible reaction (curves 1 in Fig. 2.36). Due to the effect of the chemical reaction which consumes the O species and produces the R form, the reverse component decreases and the forward component enhances correspondingly (curves 2 in Fig. 2.36). When the response is controlled exclusively by the rate of the chemical reaction, both components of the response are sigmoidal curves separated by 2i sw on the potential axes. As shown by the inset of Fig. 2.36, it is important to note that the net currents are bell-shaped curves for any observed kinetics of the chemical reaction, with readily measurable peak current and potentials, which is of practical importance in electroanalytical methods based on this electrode mecharusm. [Pg.55]

The tendency of premixed flames to detach from the flame holder to stabilize further downstream has also been reported close to the flammability limit in a two-dimensional sudden expansion flow [27]. The change in flame position in the present annular flow arrangement was a consequence of flow oscillations associated with rough combustion, and the flame can be particularly susceptible to detachment and possible extinction, especially at values of equivalence ratio close to the lean flammability limit. Measurements of extinction in opposed jet flames subject to pressure oscillations [28] show that a number of cycles of local flame extinction and relight were required before the flame finally blew off. The number of cycles over which the extinction process occurred depended on the frequency and amplitude of the oscillated input and the equivalence ratios in the opposed jets. Thus the onset of large amplitudes of oscillations in the lean combustor is not likely to lead to instantaneous blow-off, and the availability of a control mechanism to respond to the naturally occurring oscillations at their onset can slow down the progress towards total extinction and restore a stable flame. [Pg.310]

Not all methods require each parameter detailed in table 8.2 to be established. For example, a method that only measures the active ingredient in a 100-mg cold cure as part of a quality control protocol is not concerned with limit of detection, the matrix is fixed, and the calibration range might only need to be established between 80 and 120 mg. An analysis that determines the presence or absence of the target analyte needs only to establish its selectivity, limit of detection, and ruggedness. Table 8.3 details some common analytical systems with their critical method validation parameters. [Pg.232]

In situ measurements of the emission and absorption characteristics of the atmosphere always lag behind theoretical developments and laboratory studies. This is primarily attributable to equipment limitations. The laboratory environment is basically friendly, and there, experimenters are not usually faced with limitations of equipment weight, size, and power, and there is no necessity to design to meet adverse environmental conditions. This is not the case when field measurements are undertaken. In the field the elements mentioned above must be considered and solutions provided in order to conduct successful measurement programs. This paper provides a brief synopsis of developments in IR spectroscopy, compares basic system components, and discusses some of our recent efforts to extend measurements techniques, which are now common under controlled laboratory conditions, to the more difficult situation of actual atmospheric measurements. He have not presented a detailed study of a specific single example. Rather, we chose to discuss two typical field instruments and highlight the development of the components of these instruments that ultimately allowed successful system deployment. [Pg.218]

The validity interval is the time period during which relevant measurement operations are maintained in control with acceptable repeatabilities by each laboratory involved. This important limitation of validity of a traceability link is provided by design or could be im-... [Pg.18]

According to the above definition, a result that is not expressed in SI units can meet the requirements for traceability. Note that in this case each traceability link is established for a stated chemical purpose. It is asserted that such a value is obtained by a measurement applicable to the measurand, in a particular laboratory using a specific procedure, over a time period during which relevant measurement operations are maintained under control with acceptable repeatabilities, and within a limited range of magnitude of the measurand. [Pg.56]


See other pages where Control with limited measurements is mentioned: [Pg.108]    [Pg.108]    [Pg.760]    [Pg.234]    [Pg.225]    [Pg.472]    [Pg.365]    [Pg.333]    [Pg.49]    [Pg.14]    [Pg.141]    [Pg.272]    [Pg.1048]    [Pg.80]    [Pg.41]    [Pg.230]    [Pg.523]    [Pg.126]    [Pg.154]    [Pg.192]    [Pg.64]    [Pg.234]    [Pg.191]    [Pg.223]    [Pg.108]    [Pg.264]    [Pg.393]    [Pg.487]    [Pg.88]    [Pg.553]    [Pg.917]    [Pg.280]    [Pg.98]    [Pg.364]    [Pg.11]    [Pg.232]    [Pg.227]    [Pg.93]    [Pg.431]    [Pg.153]    [Pg.568]   
See also in sourсe #XX -- [ Pg.103 , Pg.104 ]




SEARCH



Control limit

Control measurements

Control measures

Controllability measures

Controller Control limits

Controller limitations

Controls controller limitations

Controls limitations

Measurement limitations

Measurements with

© 2024 chempedia.info