Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Control pulsed operation

Depending on conditions XTVI can use both stationary, mobile or small-size pulse X-ray units like RUP-150/300, RUP-120, "Arina-02". The tests of unit showed effective operation of XTVI in conjunction with program-controlled pulse X-ray units RAP-90, RAP-160, RAP-300, developed in Introscopy Institute. [Pg.449]

Special safety constraints apply to equipment selection, design, and operation in nuclear reprocessing (269). Equipment should be reHable and capable of remote control and operation for long periods with minimal maintenance. Pulsed columns and remotely operated mixer—settlers are commonly used (270). The control of criticaHty and extensive monitoring of contamination levels must be included in the process design. [Pg.80]

System Control The control unit operates all the functions of the extractor. It is composed of a CRT, keyboard, contact closure outputs and inputs and nine control cards each with special functions. This unit requires almost no modification since its functions are highly specialized and the circuits are delicately assembled. The most important function to the user is its ability to interface with other instruments. This is done via the contact closures. Of primary use in our design is the contact closure which controls the event end output pulse. In the Suprex Model 50, this is contact closure B. This event end contact closure is the main interface in our design to other in-... [Pg.161]

The advantages of a monopropellant over a bipropellant combination result primarily from a substantial reduction in the number of components in the tankage and flow hardware. The attractive simplications in the propulsion system resulting from the use of monopropellants are obtained only at the expense of a reduced specific impulse. The resulting implied trade-off between simplicity and propellant performance limits the attractiveness of monopropellants to propulsion systems where a simplicity and the usually associated reliability which comes with simplicity are premium desired characteristics. Typical applications have included attitude control rockets, vernier rockets for mid-course trajectory corrections, and other low thrust propulsors, especially those having a requirement for pulsed operation or repeated restarts. Monopropellants also find application as a source of relatively low temperature working fluids, as for driving gas turbines. [Pg.108]

In a pulsed-mode NMR experiment, which is performed at both constant magnetic field and constant rf frequency, rf radiation is supplied by a brief but powerful computer-controlled pulse of rf current through the transmitter coil. This monochromatic (single-frequency) pulse, centered at the operating frequency v0, is characterized by a power (measured in watts and controlling the magnitude of B,) and a pulse width (tp), the duration of the pulse measured in microseconds. However, as a direct consequence of the uncertainty principle [Eq. (1.6)], this brief pulse acts as if it covers a range... [Pg.33]

With ITER we will obtain the proof of principle that the magnetic confinement concept allows to gain energy from controlled thermonuclear fusion processes. It is seen as the last step before a first power plant will be built. On this way some problems have still to be solved, in particular, a power plant has to operate continuously for months, rather than the pulsed operation in present tokamaks or in ITER with 8 minutes burn time. For long time operation two requirements are crucial ... [Pg.3]

Normally the pneumatically controlled pulse feeder operates with limited pressure difference between the hopper and the stop plate. When the pressure difference is in the direction opposite to that of the downward solids flow, the downcomer needs to be lengthened in order to seal the solids, or else other modes of downcomer design must be resorted to. [Pg.315]

Phases gas-liquid, liquid-liquid. Gas liquid residence tune, short. Use for very fast reactions all reaction is in the liquid film and is mass transfer-controlled. Gas-liquid surface area, max. observed 800 m /m with the usual range 200 to 500 m /m or slightly higher than a bubble column. Target species Henry s law constant <10 kPa/mol fraction feed gas concentration <1 vol%. Not for foaming, corrosive, or particulates. Liquid-liquid can operate as gravity flow or with fluid pulsed operation. For pulsed operation surface area 75 to 3000 m /m. Related topics are solvent extraction (Section 16.11.4.10). [Pg.1417]

The KS-87B camera is in the Department of Defense inventory. It is a pulse-operated frame camera with a high-speed focal plane shutter, integral automatic exposure control and data recording, and forward... [Pg.86]

Some modern (new in 1981) commercial NMR spectrometers are extremely versatile with computer controlled pulse sequence generators which are easily programmable even for complex sequences. Thus, even for a homemade machine, you should seriously consider purchasing the operating system software with a computer and a pulse sequence generator. [Pg.338]

Figure 11-2 Complex response of human cells to sub-lethal levels of nitric oxide. IMR-90 cells (normal, diploid human embryonic lung fibroblasts) were exposed to NO at 280 nM s" for 90 minutes, and then pulse-labeled for a further 90 minutes prior to two-dimensional gel analysis. The protein species listed (by Mr) behaved reprodudbly over several experiments. At least two dififeient control pathways operate in this induction transcriptional activation, as seen with CL-100, a MAP kinase phosphatase, and stabilization of mRNA, as found for HO-1 (see [35] for details). The induction of HO-1 and other activities by NO confers adaptive resistance to NO in rodent motor neurons [40],... Figure 11-2 Complex response of human cells to sub-lethal levels of nitric oxide. IMR-90 cells (normal, diploid human embryonic lung fibroblasts) were exposed to NO at 280 nM s" for 90 minutes, and then pulse-labeled for a further 90 minutes prior to two-dimensional gel analysis. The protein species listed (by Mr) behaved reprodudbly over several experiments. At least two dififeient control pathways operate in this induction transcriptional activation, as seen with CL-100, a MAP kinase phosphatase, and stabilization of mRNA, as found for HO-1 (see [35] for details). The induction of HO-1 and other activities by NO confers adaptive resistance to NO in rodent motor neurons [40],...
Finally, a phenomenon which may indirectly entail casualties is the electromagnetic pulse (BMP). An atomic explosion causes highly variable ionization currents and the consequent electromagnetic fields generate electric currents in conducting objects. Serious faults and malfunctions of control and operation systems are likely the ubiquitous microprocessor-based systems are particularly sensitive to BMP effects. [Pg.217]

It is important to understand that ITER (O Fig. 60.10) will not be a fusion reactor, but a combined plasma confinement and fusion technology experiment. From the plasma physics point of view, it should demonstrate plasma operation under reactor conditions with Q = 10 in 500 s pulses. The plasma current would be driven inductively. Long pulse operations are planned with noninductive current drive at about Q = 3 fusion performance. ITER should demonstrate plasma operation with dominant alpha particle heating and should be capable of exploring diagnostics and plasma control schemes toward a reactor. [Pg.2791]

In the early works, it was found that the pulse method could lead to the fastest heating of epoxy resins [98] and improve their mechanical properties [99]. For example, it was shown that a computer controlled pulsed microwave processing of epoxy systems that consisted of diglycidyl ether of bisphenol A (DER 332) and 4,4 -diaminodiphenyl sulfone (DOS) in a cavity operated in TM012 mode could be successfully applied to eliminate the exothermic temperature peak and maintain the same cure temperature at the end of the reaction [100]. The epoxy systems under pulsed microwave irradiation were cured faster, and it was possible to cure them at higher temperatures when compared with a continuous microwave or conventional thermal processing. [Pg.233]

First, the following components will have to be included into the operational behavior analysis the mechanical design of the valve, the hydraulic control element, the control pulse, the position transmitter of valve (2), the manual control of valve (2), the operation of the manual control element by the operator from the control panel, the acoustical alarm sounded for faulty positioning, and the information on the operational mode of the valve (visual display). Furthermore, a second position indicator (2z) is introduced as an additional component. The function of the acoustical alarm and the level indicator are dependent on the proper functioning of the position transmitter. An analysis based on the decision table (see Figure 5.23) provides the following information. [Pg.142]

Fig. 6. Block scheme of the galvanostat with the microcomputer control OA -operational amplifier, R - 1 kQ resistor, SG - pulse generator, DAS - data aquisition system, pC-microcomputer... Fig. 6. Block scheme of the galvanostat with the microcomputer control OA -operational amplifier, R - 1 kQ resistor, SG - pulse generator, DAS - data aquisition system, pC-microcomputer...
Figure 1 presents a schematic overview of a typical molecular beam time-of-flight mass spectrometer equipped with a laser desorption source. In the studies presented in this book, the sample bar is made from graphite. Accurate positioning of the sample bar with respect to the nozzle is required for optimal performance. It is typically mounted on a double translation stage (Fig. 1). The vertical travel (x-direction) with a typical accuracy better than 0.01 mm allows for optimal cooling with minimal distortion of the molecular beam expansion. The sample bar is typically positioned about 0.1 mm below the aperture of the pulsed molecular beam valve. Travel in the horizontal direction (y-axis) of 50 mm (length of the sample bar) with a position accuracy of about 0.1 mm ensures desorption of fresh sample at every laser shot. Both positioning options can be controlled under operating conditions. Finally, the distance along the molecular beam (z-axis)... Figure 1 presents a schematic overview of a typical molecular beam time-of-flight mass spectrometer equipped with a laser desorption source. In the studies presented in this book, the sample bar is made from graphite. Accurate positioning of the sample bar with respect to the nozzle is required for optimal performance. It is typically mounted on a double translation stage (Fig. 1). The vertical travel (x-direction) with a typical accuracy better than 0.01 mm allows for optimal cooling with minimal distortion of the molecular beam expansion. The sample bar is typically positioned about 0.1 mm below the aperture of the pulsed molecular beam valve. Travel in the horizontal direction (y-axis) of 50 mm (length of the sample bar) with a position accuracy of about 0.1 mm ensures desorption of fresh sample at every laser shot. Both positioning options can be controlled under operating conditions. Finally, the distance along the molecular beam (z-axis)...
To study details of the activity and selectivity behavior of a catalyst, or to get a reaction engineering fingerprint of different catalysts a microprocessor controlled pulse reactor combined with a gaschromatograph or mass-spectrometer is a very powerful tool, especially if it is operated under temperature programmed conditions. Fig. 26 shows the flow diagram of such a unit developed in our laboratory /46/. [Pg.94]


See other pages where Control pulsed operation is mentioned: [Pg.314]    [Pg.314]    [Pg.410]    [Pg.325]    [Pg.617]    [Pg.140]    [Pg.529]    [Pg.258]    [Pg.161]    [Pg.269]    [Pg.588]    [Pg.449]    [Pg.356]    [Pg.20]    [Pg.500]    [Pg.92]    [Pg.67]    [Pg.94]    [Pg.211]    [Pg.1109]    [Pg.241]    [Pg.144]    [Pg.138]    [Pg.178]    [Pg.425]    [Pg.426]    [Pg.230]    [Pg.231]    [Pg.579]    [Pg.89]    [Pg.191]    [Pg.154]   
See also in sourсe #XX -- [ Pg.111 ]




SEARCH



Controller Operation

Operation control

Operational controls

Pulse control

Pulsed operation

© 2024 chempedia.info