Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Connection advanced

Chemically-induced alterations in sexual and functional development the wildlife/human connection. Advances in Modem Environmental Toxicology, Vol. XXI. Princeton, NJ Princeton Scientific Publishing Co., Inc., 335-345. [Pg.188]

Knowledge often grows by what, to outsiders, looks like free association. Obscure technical threads, invisible to the untrained eye, connect advances in one field to apparently unrelated discoveries in others. Only to the specialists in these fields, for whom the foreground... [Pg.67]

In addition, most devices provide operator control of settings for temperature and/or response slope, isopotential point, zero or standardization, and function (pH, mV, or monovalent—bivalent cation—anion). Microprocessors are incorporated in advanced-design meters to faciHtate caHbration, calculation of measurement parameters, and automatic temperature compensation. Furthermore, pH meters are provided with output connectors for continuous readout via a strip-chart recorder and often with binary-coded decimal output for computer interconnections or connection to a printer. Although the accuracy of the measurement is not increased by the use of a recorder, the readabiHty of the displayed pH (on analogue models) can be expanded, and recording provides a permanent record and also information on response and equiHbrium times during measurement (5). [Pg.467]

Automatic filters are made with either viscous-coated or dry filter media. However, the cleaning or disposal of the loaded medium is essentially continuous and automatic. In most such devices the air passes horizontally through a movable filter curtain. As the filter loads with dust, the curtain is continuously or intermittently advanced to expose clean media to the air flow and to clean or dispose of the loaded medium. Movement of the curtain can be provided by a hand crank or a motor drive. Movement of a motor-driven curtain can be actuated automatically by a differential-pressure switch connected across the filter. [Pg.1608]

Understanding the positions of sample and other measurement locations within the equipment is also important. The presence or absence of isolation valves needs to be identified. While isolation valves may be too large for effective sampling, their absence will require that pipe fitters add them such that sample valves can be connected. This must be done in advance of any test. If analysts assume that samples are from a liquid stream when they are vapor or that temperature measurements are within a bed instead of outside it, interpretation of results could be corrupted. Analysts should also develop an understanding of control transmitters and stations. The connection between these two may be difficult to identify at this level in fully computer-controlled units. [Pg.2553]

T. Colborn and C. Clement, Advances in Modern Environmental Toxicology Volnme XXL Chemically-Induced Alterations in Sexual and Functional Development The Wildlife/Human Connection, Princeton Scientific, New Jersey, 1992. [Pg.1]

W. P. Davis and S.A. Bortone, Advances in Modern Environmental Toxicology Volume XXL Chemically-Induced Alterations in Sexual and Eunctional Development The Wildlife/Human Connection, ed. T. Colborn and C. Clement, Princeton Scientific, New Jersey, 1992, p. 113. D.L. MacLatchy, Z. Yao, L. Tremblay and G.J. Van Der Kraak, in Proceedings of the 5th International Symposinm on Reprodnctive Physiology of Eish, University of Texas, Austin, 1997, p. 189. P. E. Gibbs and G. W. Bryan, in Biomonitoring of Coastal Waters and Estuaries, ed. K. J. M. Kramer, CRC Press, Boca Raton, FL, 1994, p. 205. [Pg.11]

With the availability of more advanced interrupters in future, it will be possible to upgrade the present guidelines and permit connections of more feeding lines on an existing grid without having to resort to a series reactor. [Pg.347]

Instruments based on the contact principle can further be divided into two classes mechanical thermometers and electrical thermometers. Mechanical thermometers are based on the thermal expansion of a gas, a liquid, or a solid material. They are simple, robust, and do not normally require power to operate. Electrical resistance thermometers utilize the connection between the electrical resistance and the sensor temperature. Thermocouples are based on the phenomenon, where a temperature-dependent voltage is created in a circuit of two different metals. Semiconductor thermometers have a diode or transistor probe, or a more advanced integrated circuit, where the voltage of the semiconductor junctions is temperature dependent. All electrical meters are easy to incorporate with modern data acquisition systems. A summary of contact thermometer properties is shown in Table 12.3. [Pg.1136]

Corrosion by essentially pure steam arises principally in connection with power generating plant. Temperatures up to about 600°C in association with pressures up to about 15 MN/m are involved, although in the most advanced super-critical installations being planned for the future, temperatures of 650°C and pressures of 40MN/m are under consideration. The highest temperatures occur in the superheater tubes, but it is probable that the severest corrosion conditions on these components will arise from the presence of fuel ashes on the outside of the tubes rather than from the steam on the inside. Perhaps the most critical components in such installations will... [Pg.954]

We note that this quantity has a meaning in this connection, only if Wq has been multiplied in advance by a phase factor eia chosen so that the overlap integral... [Pg.263]


See other pages where Connection advanced is mentioned: [Pg.196]    [Pg.213]    [Pg.196]    [Pg.213]    [Pg.848]    [Pg.849]    [Pg.2832]    [Pg.768]    [Pg.11]    [Pg.196]    [Pg.1183]    [Pg.351]    [Pg.32]    [Pg.205]    [Pg.251]    [Pg.496]    [Pg.123]    [Pg.195]    [Pg.7]    [Pg.66]    [Pg.720]    [Pg.168]    [Pg.515]    [Pg.45]    [Pg.1183]    [Pg.28]    [Pg.33]    [Pg.337]    [Pg.495]    [Pg.74]    [Pg.431]    [Pg.956]    [Pg.1348]    [Pg.3]    [Pg.70]    [Pg.123]    [Pg.804]    [Pg.86]    [Pg.102]    [Pg.196]    [Pg.198]   
See also in sourсe #XX -- [ Pg.458 ]




SEARCH



Optimized Micromixer with an Advanced Connection System

© 2024 chempedia.info