Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Column approximation

The dimensions of the alumina column arc not critical A column approximately 2 5 cm by 12 5 cm is recommended The small amount of bis(4-methylphenyl)thallium bromide formed in the reaction remains on the top of the column... [Pg.50]

At sea level, atmospheric pressure supports a mercury column approximately 760 mm in height. Changes in altitude and weather cause fluctuations in atmospheric pressure. Nevertheless, at sea level the height of the mercury column seldom varies by more than 10 mm, except under extreme conditions, such as in the eye of a hurricane, when the mercury in a barometer may fall below 740 mm. [Pg.282]

FIGURE 12.5 Human serum tryptic digest analysis. Fractionation in the first LC dimension was performed using a C18 column at pH 10. Fractions were analyzed using NanoEase 0.3 x 150 mm Atlantis d18 column. Approximately 66 lg (400 pmole of semm albumin peptides) was injected on column. Arrow points to a selected albumin peptide illustrating a local column mass overloading. Ten-5mm wide fractions were collected in 1st LC dimension. [Pg.283]

A consideration of axial dispersion is essential in any realistic description of extraction column behaviour. Here a dynamic method of solution is demonstrated, based on a finite differencing of the column height coordinate. Figure 1 below shows the extraction column approximated by N finite-difference elements. [Pg.468]

Swamy, C. and Shmoys, D.B. (2006) Algorithms column approximation algorithms for two-stage stochastic optimization problems. ACM SIGACT News, 37, 1. [Pg.138]

A simple —but incorrect — relationship between the height of capillary rise, capillary radius, contact angle, and surface tension is easily derived. At equilibrium the vertical component of the surface tension (2icRcy cos 0) equals the weight of the liquid column, approximated as the weight of a cylinder of height h and radius Rc. This leads to the approximation... [Pg.254]

The seasonal variations of Cr(VI) in the water column of Lake Greifen (83) are illustrated by Figure 7. In the mixed lake, the concentration of Cr(VI) is uniform throughout the water column (approximately 2.5 nM). During stagnation, the concentration of Cr(VI) increases in the epilimnion and decreases in the hypolimnion. This separation can be explained by a slow removal process in the bottom waters, while at the same time Cr(VI) enters only the epilimnion and is cut off from the hypolimnetic waters. In the late stagnation time (November 1989), the concentration of Cr(VI) close to the sediment-water interface decreases. Cr(III), however, cannot be detected in solution. [Pg.485]

Fig. 2.6. Schematic representation of a dry-box purification scheme. (A) Glove box (B) tank argon (C) purge line for pump container (D) gastight pump container (E), 2.7 ft /min graphite ring pump (F) bubbler (G) purification train consisting of Linde 13X and 4A Molecular Sieves, and Vermiculite-supported MnO at room temperature (see Chapter 3). In some installations an additional drying column follows the MnO column. Approximate column dimensions are 3-in. diameter by 4-ft length. (Unpublished design of T. L. Brown.)... Fig. 2.6. Schematic representation of a dry-box purification scheme. (A) Glove box (B) tank argon (C) purge line for pump container (D) gastight pump container (E), 2.7 ft /min graphite ring pump (F) bubbler (G) purification train consisting of Linde 13X and 4A Molecular Sieves, and Vermiculite-supported MnO at room temperature (see Chapter 3). In some installations an additional drying column follows the MnO column. Approximate column dimensions are 3-in. diameter by 4-ft length. (Unpublished design of T. L. Brown.)...
In order to test the laboratory data obtained, a small extractor system was used with those solvents having suitable properties, which were obtainable in sufficient quantities for testing, using natural waters or sodium chloride solutions. The extraction system consists of a 2-inch packed column approximately 4 feet high to which water and solvent were fed countercurrently. An analysis of the resulting extract feed and brine was made to determine the material balance for the system. The data obtained from this column using diisopropylamine as solvent are shown in Table I. The feed concentration was 2000 p.p.m. of sodium chloride. The product contained 490 p.p.m., of which part was the amine hydrochloride. In practice, this would be replaced in the solvent recovery system by an equivalent amount of sodium to give the total salt content indicated. Sufficient data have been obtained to indicate that the calculations... [Pg.47]

The basic design of instrument is schematically illustrated in Fig. 2.143 and consists of a metal or glass column approximately 2-3 m in length and 2-4 mm internal diameter, which is in the form of a circular spiral of three or four turns, and packed with supporting medium impregnated with a stationary phase the column is located in a temperature controlled oven. The mobile gas phase... [Pg.223]

In addition to requiring significant bulk material, the timeframe to complete the isolation is considerable. If the maximum analytical load for a 4.6 mm x 150 mm column has been determined to be 5 mg, assuming the isolation will be performed using semi-preparative chromatography (20 mm x 300 mm column), approximately 190 mg of sample can be loaded onto the preparative column. For a 0.1% level unknown, this translates to 190 pg of unknown injected onto the preparative column. Therefore, a total of 27 injections are required. If the assay time were estimated to be 1 hr, it would take at least 27 hr to perform the injections needed to obtain 5 mg (once again assuming 100% recovery). This timeframe does not include the time needed for method scale-up development, concentration and... [Pg.465]

Experimental Procedure. Gas flow was initially fed to a column approximately 2/3 full of slurry. After the gas flow rate was set, the slurry flow was started and adjusted using the calibrated volume. Flow rates were held constant during the runs, which lasted 1+5 to 75 minutes for the 12.7 cm column, and 180 minutes for the 30.5 cm column. At the end of this time, slurry samples were taken, starting at the top of the column and working down, so as not to disturb upstream conditions. All slurry ports were purged before taking a sample, and stopcocks were turned quickly to full open and full closed to prevent settling of slurry within the sample line. [Pg.112]

The spatial resolution depends on several factors the electron probe size, the probe broadening in the sample due to diffraction, the beam direction relative to the strain axes. Theoretical consideration based on the column approximation suggests that the resolution in the zone-axis orientation can be as small as a few nanometers. In the case of a thick sample, the resolution is limited by the probe broadening. ... [Pg.6041]

In order to further define the chemical nature of the fungal complexes with high Ni affinity, the exocellular solution from organism 458 was subjected to GPC. Organic C was eluted over the entire separation range of the column (approximately 300 to 3000... [Pg.194]

In developing the kinematical theory, we made use in Section 3.7 of the column approximation. In view of the preceding discussion, it is important to estimate the crystal thickness t for which the column approximation is valid. If kinematical conditions are to apply within a single column of unit cells of width x, and adjacent columns are to diffract independently of each other, then 2 t < x. Thus, for x 0.5 nm, the crystal thickness must be less than about 25 nm. [Pg.89]

Since the Bragg angles are small, we can assume that both the transmitted and the scattered waves are propagating in a narrow column of crystal. Thus, we can consider T and S to be functions of z only and for the column approximation. [Pg.125]

Proceeding in the same manner as before, we find for the column approximation that... [Pg.125]

Recombinant human interleukin-2 (rIL-2, previously known as T-cell growth factor) was expressed in E. coli (7). During the purification process of rIL-2 by reversed-phase HPLC, another higher molecular weight form of this protein was also isolated, known as HMW rIL-2 (8). The purification process of HMW rIL-2 involved two chromatography steps and utilized a Bakerbond Carboxy-Sulfon (CS) column. Approximately 2 nmol each of rIL-2 and HMW rIL-2 were immobilized using ProSpin cartridges for C-terminal sequence analysis. [Pg.230]

The ether solutions are combined, and the solution is dried over 100 g. of calcium chloride for at least 3 hours. The purple solution is filtered and then evaporated in a rotating evaporator to a syrupy residue. The tarry red residue is dissolved in 100 ml. of hot (70°) benzene. The benzene solution is allowed to cool and is then poured onto a chromatographic column (approximately 35 X 300 mm.) packed under benzene with 50 g. of activated aluminum oxide. A dark violet band is rapidly eluted from the column with methylene chloride (dichloromethane). Evaporation of the violet methylene chloride solution yields 2.2 to 2.8 g. of purple crystals (20 to 26%) m.p. 182 to 183°. [Pg.143]

Clamp a column (approximately 1.5 cm x 40 cm) to a stand, and with the outlet closed run a small volume of PBS into the column. Pour the Sephadex G-50 suspension into the colunm and allow to settle until approximately 1 cm of column length is filled. Open the outlet to allow a flow of PBS, which facilitates column packing. Add more Sephadex slurry to give a packed volume of one-third of the column length, with a reasonable depth of PBS above the packed Sephadex. Close the outlet. [Pg.128]

The petroleum ether phase was then run into a silica gel column (approximately 500 g of silica gel) and eluted with a mixture of petroleum ether (50/70) and diisopropylether (2 1). The eluate was reduced in volume under vacuum and the residue (approximately 102 g) was recrystallized from 600 mL of petroleum ether (50/70). 77 g of the desired product were obtained. The characteristic data of the 6,12-dihydro-6-hydroxy-cannabidiol were as follows Fusion point 77° to 77.5° C. [Pg.56]

Almost all patients with disease located outside the lungs should receive antifungal therapy therapy usually is initiated with 400 mg.day of an oral azole. Amphotericin B is an alternative therapy and may be necessary in patients with worsening lesions or with disease in particularly critical locations such as the vertebral column. Approximately 50% to 75% of patients treated with amphotericin B for nonmeningeal disease achieve a sustained remission, and therapy usually is curative in patients with infections localized strictly to skin and soft tissues without extensive abscess formation or tissue damage. The efficacy of local injection into joints or the peritoneum, as well as intraarticularor intradermal administration, remains poorly studied. Amphotericin B appears to be most efficacious when cell-mediated immunity is intact (as evidenced by a positive coccidioidin or spherulin skin test or low CF antibody titer). Controlled trials that document these clinical impressions are lacking, however. ... [Pg.2173]


See other pages where Column approximation is mentioned: [Pg.52]    [Pg.542]    [Pg.70]    [Pg.181]    [Pg.361]    [Pg.348]    [Pg.83]    [Pg.164]    [Pg.66]    [Pg.49]    [Pg.358]    [Pg.26]    [Pg.27]    [Pg.789]    [Pg.97]    [Pg.149]    [Pg.560]    [Pg.57]    [Pg.473]    [Pg.66]    [Pg.187]   
See also in sourсe #XX -- [ Pg.71 , Pg.89 , Pg.125 ]




SEARCH



© 2024 chempedia.info