Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Collector packings

A multipoint collector is an assembly (array) of single-point collectors (elements), packed closely together in a plane. [Pg.409]

Fig. 22. Performance cut diameter predictions for typical dry packed bed particle collectors as a function of bed height or depth, packing diameter and packing porosity (void area) S. Bed irrigation increases collection efficiency or decreases cut diameter (271). SoHd lines, = 25 mm dashed lines,... Fig. 22. Performance cut diameter predictions for typical dry packed bed particle collectors as a function of bed height or depth, packing diameter and packing porosity (void area) S. Bed irrigation increases collection efficiency or decreases cut diameter (271). SoHd lines, = 25 mm dashed lines,...
The gas risers must have a sufficient flow area to avoid a high gas-phase pressure drop. In addition, these gas risers must be uniformly positioned to maintain proper gas distribution. The gas risers should be equipped w ith covers to deflect the liquid raining onto this collector plate and prevent it from entering the gas risers where the high gas velocity could cause entrainment. These gas riser covers must be kept a sufficient distance below the next packed bed to allow the gas phase to come to a uniform flow rate per square foot of column cross-sectional area before entering the next bed. [Pg.83]

Where only about 5% or less of the liquid dow iiflow is to be withdrawn from the column, a special collector box can be installed within the packed bed. This box can remove small quantities of intermediate boiling components that otherwise w ould accumulate in a sufficient quantity to interfere with the fractionation operation. Such a collector box must be designed very carefully to avoid interference with the vapor distribution above it or... [Pg.83]

Schrader Environmental Systems, Inc. Air pollution control technologies such as catalytic oxidizers, packed tower wet scrubbers, dust collectors. http //WWW. anseWre. com... [Pg.343]

Spray-type collectors In this system water is sprayed or cascaded onto the contaminated air directly or through packed towers, and the fumes or dust are washed away by absorption. These collectors are used extensively on the treatment of fumes of all types and have low pressure drops and hence low power requirements compared to induced spray. A development of this collector is the venturi scrubber, which injects high-pressure water into a venturi through which the fume-laden air is passing. The intimate contact of the two ensures absorption and removal from the air stream. These collectors are used in fume removal and have efficiencies of more than 99 per cent on sub-micron particles. [Pg.769]

System of packed bed solar air heaters The system has a total solar heat collector area of 27 m2 consisting of 18 packed bed solar air heaters (Demirel... [Pg.141]

He et al. (2002) used an off-line HPLC/CE method to map cancer cell extracts. Frozen ovarian cancer cells (containing 107 cells) were reconstituted in 300 pL of deionized water and placed in an ultrasonic bath to lyse the cells. Then the suspension was centrifuged and the solubilized proteins were collected for HPLC fractionation. The HPLC separation was carried out on an instrument equipped with a RP C-4 column, 250 mm x 4.6 mm, packed with 5-pm spherical silica particles. Extracted proteins were dissolved in 300 pL of DI water, and lOOpL was injected onto the column at a flow rate of 1 mL/min. Buffer A was 0.1% TEA in water and buffer B was 0.1% TFA in acetonitrile. A two-step gradient, 15-30% B in 15 min followed by 30-70% B in 105 min, was used. The column effluent was sampled every minute into a 96-well microtiter plate with the aid of an automatic fraction collector. After collection, the fractions were dried at room temperature under vacuum. The sample in each well was reconstituted before the CE analysis with 10 pL deionized water. The... [Pg.378]

The NiOx particles, when in operation, are closely packed with conductive additive by means of pressing of the electrode block or addition of a binder into the active mass slurry. The quantity of conductive additive should be chosen pursuing the necessity to create a spatially ramified grid providing current transmission from the active material particles to an external collector. In dependence on reciprocal dispersion of conductive additive and active material, the quantity of conductor in the mass may vary from 10wt% to 70wt% of the total electrode mass. [Pg.51]

There are several types of wet collectors including spray towers, packed towers, and wet centrifugal collectors. The spray tower is a cylindrical or rectangular tower into which the incoming air is passed. Highspeed water sprays in the tower impact and remove the dust that is subsequently separated from the droplets by various types of eliminators. Spray towers are effective for all kinds of dust and even moisture-laden gases. [Pg.136]

A CE run can also be spotted on a matrix assisted laser desorption ionization (MALDI) plate by using a probot microfraction collector by LC Packings. The matrix solution, 2 mg/mL... [Pg.54]

Chromatography and Electrophoresis of Antigens. Cotton dust (20-30 mg) was dissolved in water and passed through a small column (30 x 1.5 cm id) packed with 3 g of Sephadex G-75 that had been preswelled in water. Chromatograms were obtained with an LKB Uvicord ultraviolet monitor and a chopper bar recorder. Volumes of 5 ml each were collected in test tubes with an automatic fraction collector. Two components were detected at 250 nm. Samples of 10 mg were analyzed by disc gel electrophoresis according to procedures described by Davis (36), and Zacharius (37). [Pg.263]

HPLC and Isolation of Mutagenic Fractions. Analytical and semipreparative reverse-phase HPLC separations were performed by using a water-to-acetonitrile linear gradient (J2). Separations were carried out on a Hewlett Packard Model 10084 B equipped with an automatic sampling device, a solvent programmer, a variable absorbance detector, and an automatically steered fraction collector. The instrument was fitted with a 3.9-mm X 30-cm prepacked analytical column of 10-/zm silica particles bonded with octadecylsilane (Bondapack-Cis) for analytical scale. For semipreparative scale separations, the HPLC was fitted with a 7.8-mm X 30-cm prepacked column packed with 10-/xm silica particles bonded with octadecylsilane. Samples for HPLC were injected at volumes of 20 /xL (flow rate 1 mL/min) and 80 /zL (flow rate 4 mL/min), and the absorption was measured at 254 nm. Fractions... [Pg.590]

Figure 7.4 shows a modern, narrow-trough, liquid collector-vapor distributor chimney tray. While the initial vapor distribution through a packed bed is not quite so critical or difficult as the liquid distribution, it is still important. [Pg.78]

The lithological and structural features of building rocks are as follows for collectors - there are sandstone packs in the shale rock layers of Maikop stratum Sakaraulo horizon with about 10mm capacity. Its gas-proof lid is more than 500 meter strong Maikop stratum upper Kotsakhuri horizon shale rock, with rare streaks of finest rock sandstone. [Pg.240]

Effect of Multiple Layers and Packing All correlations for the collection efficiency discussed so far are based on the ideal case of a single cylindrical collector. Now, let s examine a filter unit consisting of randomly oriented multiple layers. Consider an area (A) of filter at a right angle to the gas flow and with a depth dh. If the packing density a is defined as the volume of fiber per unit volume of filter bed, the velocity within the filter void space is equal to... [Pg.212]


See other pages where Collector packings is mentioned: [Pg.214]    [Pg.214]    [Pg.196]    [Pg.219]    [Pg.402]    [Pg.327]    [Pg.1428]    [Pg.1433]    [Pg.1439]    [Pg.12]    [Pg.21]    [Pg.351]    [Pg.736]    [Pg.413]    [Pg.185]    [Pg.170]    [Pg.1089]    [Pg.537]    [Pg.333]    [Pg.138]    [Pg.8]    [Pg.9]    [Pg.590]    [Pg.23]    [Pg.251]    [Pg.142]    [Pg.240]    [Pg.244]    [Pg.213]    [Pg.53]    [Pg.72]    [Pg.72]    [Pg.74]    [Pg.113]    [Pg.117]   
See also in sourсe #XX -- [ Pg.778 , Pg.792 , Pg.802 , Pg.803 , Pg.806 , Pg.807 , Pg.818 , Pg.821 , Pg.822 , Pg.831 , Pg.844 , Pg.854 , Pg.883 ]