Pankow, J.F. and Janauer, G.E. (1974) Analysis for chromium traces in natural waters. 1. Pre-concentration of chromate from parts per billion levels in aqueous solutions by ion exchange. Anal. Chim. Acta, 69, 97-104. [Pg.86]

For the direct speciation analysis of chromium traces only a few techniques are available. [Pg.688]

Analysis of Trace or Minor Components. Minor or trace components may have a significant impact on quaHty of fats and oils (94). Metals, for example, can cataly2e the oxidative degradation of unsaturated oils which results in off-flavors, odors, and polymeri2ation. A large number of techniques such as wet chemical analysis, atomic absorption, atomic emission, and polarography are available for analysis of metals. Heavy metals, iron, copper, nickel, and chromium are elements that have received the most attention. Phosphoms may also be detectable and is a measure of phosphoHpids and phosphoms-containing acids or salts. [Pg.134]

The physical and mechanical properties of steel depend on its microstmcture, that is, the nature, distribution, and amounts of its metaHographic constituents as distinct from its chemical composition. The amount and distribution of iron and iron carbide determine most of the properties, although most plain carbon steels also contain manganese, siUcon, phosphoms, sulfur, oxygen, and traces of nitrogen, hydrogen, and other chemical elements such as aluminum and copper. These elements may modify, to a certain extent, the main effects of iron and iron carbide, but the influence of iron carbide always predominates. This is tme even of medium alloy steels, which may contain considerable amounts of nickel, chromium, and molybdenum. [Pg.384]

To ensure the mtile crystal form, seed crystals are added, otherwise anatase is obtained. The precipitate is thoroughly washed using water and sulfuric acid to remove all traces of discoloring elements, eg, iron, chromium, vanadium, and manganese. The TiO(OH)2 is finally calcined at 1000°C to Ti02 (8). [Pg.97]

Brewers and bakers dried yeasts are used as dietary supplements. They contribute some protein and trace minerals, and some B vitamins, but no vitamin C, vitamin B 2 or fat-soluble vitamins. The glucose tolerance factor (GTE) of yeast, chromium nicotinate, mediates the effect of insulin. It seems to be important for older persons who caimot synthesize GTE from inorganic dietary chromium. The ceU wall fraction of bakers yeast reduces cholesterol levels in rats fed a hypercholesteremic diet. [Pg.393]

Cr C Cr C chromium iton(l l) [12052-89-0] CrFe (c phase), and chromium iron molybdenum(12 36 10) [12053-58-6] Cr 2F 36 o Q phase), are found as constituents in many alloy steels Ct2Al23 and CoCr ate found in aluminum and cobalt-based alloys, respectively. The chromium-rich interstitial compounds, Ci2H, chromium nitrogen(2 l) [12053-27-9] Ct2N, and important role in the effect of trace impurities on the... [Pg.121]

The classical wet-chemical quaUtative identification of chromium is accompHshed by the intense red-violet color that develops when aqueous Cr(VI) reacts with (5)-diphenylcarba2ide under acidic conditions (95). This test is sensitive to 0.003 ppm Cr, and the reagent is also useful for quantitative analysis of trace quantities of Cr (96). Instmmental quaUtative identification is possible using inductively coupled argon plasma—atomic emission spectroscopy... [Pg.140]

To determine moderate amounts of Cr(III) and Cr(VI) in samples that have both oxidation states present, Cr(VI) is analyzed by direct titration in one sample, and the total chromium is found in a second sample after oxidation of the Cr(III). The Cr(III) concentration is determined as the difference. Trace quantities of Cr(VI) in Cr(III) compounds can be detected and analyzed by (3)-diphenylcarbazide. Trace quantities of Cr(III) in Cr(VI) may be detected and analyzed either photometrically (102) or by ion chromatography using various modes of detection (103). [Pg.141]

Instrumental Quantitative Analysis. Methods such as x-ray spectroscopy, oaes, and naa do not necessarily require pretreatment of samples to soluble forms. Only reUable and verified standards are needed. Other instmmental methods that can be used to determine a wide range of chromium concentrations are atomic absorption spectroscopy (aas), flame photometry, icap-aes, and direct current plasma—atomic emission spectroscopy (dcp-aes). These methods caimot distinguish the oxidation states of chromium, and speciation at trace levels usually requires a previous wet-chemical separation. However, the instmmental methods are preferred over (3)-diphenylcarbazide for trace chromium concentrations, because of the difficulty of oxidizing very small quantities of Cr(III). [Pg.141]

Nutrition. Chromium, in the trivalent oxidation state, is recognized as an essential trace element for human nutrition, and the recommended... [Pg.141]

Neutralizing removes the large amount of hexavalent chromium from the surface of the part. Hexavalent chromium shortens the life of the catalyst, and trace amounts completely inhibit electroless nickel deposition. The neutralizer is usually a mildly acidic or basic reducing agent, but other types of neutralizers are available, especially for substrates that are difficult to plate. The neutralizer may also contain surfactants (qv) or other compounds that increase catalyst absorption absorption promoters are often needed for non-ABS plastics. [Pg.110]

Chromium, 122 ppm of the earth s crustal rocks, is comparable in abundance with vanadium (136 ppm) and chlorine (126 ppm), but molybdenum and tungsten (both 1.2 ppm) are much rarer (cf. Ho 1.4 ppm, Tb 1.2 ppm), and the concentration in their ores is low. The only ore of chromium of any commercial importance is chromite, FeCr204, which is produced principally in southern Africa (where 96% of the known reserves are located), the former Soviet Union and the Philippines. Other less plentiful sources are crocoite, PbCr04, and chrome ochre, Cr203, while the gemstones emerald and ruby owe their colours to traces of chromium (pp. 107, 242). [Pg.1003]

It appears that chromium(III) is an essential trace element in mammalian metabolism and, together with insulin, is responsible for the clearance of glucose from the blood-stream. Tungsten too has been found to have a role in some enzymes converting CO2 into formic acid but, from the point of view of biological activity, the focus of interest in this group is unquestionably on molybdenum. [Pg.1035]

The non-ferrous alloys include the misleadingly named nickel silver (or German silver) which contains 10-30% Ni, 55-65% Cu and the rest Zn when electroplated with silver (electroplated nickel silver) it is familiar as EPNS tableware. Monel (68% Ni, 32% Cu, traces of Mn and Fe) is used in apparatus for handling corrosive materials such as F2 cupro-nickels (up to 80% Cu) are used for silver coinage Nichrome (60% Ni, 40% Cr), which has a very small temperature coefficient of electrical resistance, and Invar, which has a very small coefficient of expansion are other well-known Ni alloys. Electroplated nickel is an ideal undercoat for electroplated chromium, and smaller amounts of nickel are used as catalysts in the hydrogenation of unsaturated vegetable oils and in storage batteries such as the Ni/Fe batteries. [Pg.1146]

The sotrace elements, such as boron, cobalt, iron,copper, zinc, manganese, chromium, molybdenum and still others may also be used to advantage. Generally, these trace elements occur in sufficient quantities in the carbonaceous and nitrogenous constituents of the medium, particularly if derived from natural sources, or in the tap water, and the addition of further quantities of these trace elements may consequently be unnecessary. [Pg.1062]

Films produced in oxalic acid contain smaller amounts (about 3%) of the electrolyte and only traces of chromium are found in chromic acid films. Sealed films show the electron diffraction pattern of the monohydrate, bohmite. [Pg.693]

Alkyl radical addition reactions to styrene chromium tricarbonyl can be accomplished using alkyl halides (10 equiv) and (TMSlsSiH (5 equiv) in the presence of AIBN in refluxing benzene, for 18 h (Reaction 66). " These reactions are believed to proceed through intermediates in which the unpaired electron is interacting with the adjacent arene chromium tricarbonyl moiety since the analogous reaction with styrene affords only traces of addition products. [Pg.148]

Mass Balance Estimates. Based on National Pollutant Discharge Elimination System monitoring reports, the total daily discharge of trace elements into the main stem Willamette River is of the order of 100 pounds per day. Seventy-five percent of the total is zinc with the bulk of the remainder due to chromium and copper. Table 6 identifies industrial and natural sources of trace elements into the Willamette basin. The table indicates that an average of 97 percent of all trace element loading to the basin is natural in origin. The natural component is due to weathering of soil and rocks in the basin and this... [Pg.276]

Aqueous standard solutions are a source of certain difficulties In electrothermal atomic absorption spectrometry of trace metals In biological fluids The viscosities and surface tensions of aqueous standard solutions are substantially less than the viscosities and surface tensions of serum, blood and other proteln-contalnlng fluids These factors Introduce volumetric disparities In pipetting of standard solutions and body fluids, and also cause differences In penetration of these liquids Into porous graphite tubes or rods Preliminary treatment of porous graphite with xylene may help to minimize the differences of liquid penetration (53,67) A more satisfactory solution of this problem Is preparation of standards In aqueous solutions of metal-free dextran (50-60 g/llter), as first proposed by Pekarek et al ( ) for the standardization of serum chromium analyses This practice has been used successfully by the present author for standardization of analyses of serum nickel The standard solutions which are prepared In aqueous dextran resemble serum In regard to viscosity and surface tension Introduction of dextran-contalnlng standard solutions Is an Important contribution to electrothermal atomic absorption analysis of trace metals In body fluids. [Pg.255]


See other pages where Chromium traces is mentioned: [Pg.55]    [Pg.55]    [Pg.348]    [Pg.380]    [Pg.68]    [Pg.502]    [Pg.55]    [Pg.56]    [Pg.373]    [Pg.7]    [Pg.54]    [Pg.377]    [Pg.241]    [Pg.412]    [Pg.90]    [Pg.141]    [Pg.486]    [Pg.415]    [Pg.3]    [Pg.435]    [Pg.1020]    [Pg.959]    [Pg.1087]    [Pg.385]    [Pg.760]    [Pg.249]    [Pg.523]    [Pg.342]    [Pg.81]    [Pg.84]    [Pg.275]    [Pg.1480]   