Chromatography refractive index

Composition Chromatography Refractive index Density Conductivity pH Infrared/ultraviolet absorption... [Pg.224]

The ratio of 1-chlorobutane to 1-bromo-butane, 2-chlorobutane to 2-bromo-butane, or ferf-butyl chloride to tert-hutyl bromide must be determined. At your instructor s option, you may do this by one of three methods gas chromatography, refractive index, or NMR spectroscopy. The products obtained from the reactions of 1-butanol and 2-butanol, however, cannot be analyzed by the refractive index method (they... [Pg.196]

Different liquid chromatography modes in polymer analysis were successfully interfaced with electrospray ionisation time-of-flight mass spectrometry in a single experimental set-up the mass spectrometry data from size exclusion chromatography/mass spectrometry of PMMA were used as absolute calibration points in the size exclusion chromatography/refractive index chromatogram, and monomer mass and end groups were inferred from the isotopically resolved mass spectra. 44 refs. [Pg.97]

Solution Polymers. Acryflc solution polymers are usually characterized by their composition, solids content, viscosity, molecular weight, glass-transition temperature, and solvent. The compositions of acryflc polymers are most readily determined by physicochemical methods such as spectroscopy, pyrolytic gas—liquid chromatography, and refractive index measurements (97,158). The solids content of acryflc polymers is determined by dilution followed by solvent evaporation to constant weight. Viscosities are most conveniently determined with a Brookfield viscometer, molecular weight by intrinsic viscosity (158), and glass-transition temperature by calorimetry. [Pg.171]

Table 4 lists the specifications set by Du Pont, the largest U.S. producer of DMF (4). Water in DMF is deterrnined either by Kad Fischer titration or by gas chromatography. The chromatographic method is more rehable at lower levels of water (<500 ppm) (4). DMF purity is deterrnined by gc. For specialized laboratory appHcations, conductivity measurements have been used as an indication of purity (27). DMF in water can be measured by refractive index, hydrolysis to DMA followed by titration of the Hberated amine, or, most conveniendy, by infrared analysis. A band at 1087 cm is used for the ir analysis. [Pg.514]

When simple Hquids like naphtha are cracked, it may be possible to determine the feed components by gas chromatography combined with mass spectrometry (gc/ms) (30). However, when gas oil is cracked, complete analysis of the feed may not be possible. Therefore, some simple definitions are used to characterize the feed. When available, paraffins, olefins, naphthenes, and aromatics (PONA) content serves as a key property. When PONA is not available, the Bureau of Mines Correlation Index (BMCI) is used. Other properties like specific gravity, ASTM distillation, viscosity, refractive index. Conradson Carbon, and Bromine Number are also used to characterize the feed. In recent years even nuclear magnetic resonance spectroscopy has been... [Pg.434]

Composition The law of mass aclion is expressed as a rate in terms of chemical compositions of the participants, so ultimately the variation of composition with time must be found. The composition is determined in terms of a property that is measured by some instrument and cahbrated in terms of composition. Among the measures that have been used are titration, pressure, refractive index, density, chromatography, spectrometry, polarimetry, conduclimetry, absorbance, and magnetic resonance. In some cases the composition may vary linearly with the observed property, but in every case a calibration is needed. Before kinetic analysis is undertaken, the data are converted to composition as a function of time (C, t), or to composition and temperature as functions of time (C, T, t). In a steady CSTR the rate is observed as a function of residence time. [Pg.707]

Thin-layer chromatography (TLC) is used both for characterization of alcohol sulfates and alcohol ether sulfates and for their analysis in mixtures. This technique, combined with the use of scanning densitometers, is a quantitative analytical method. TLC is preferred to HPLC in this case as anionic surfactants do not contain strong chromophores and the refractive index detector is of low sensitivity and not suitable for gradient elution. A recent development in HPLC detector technology, the evaporative light-scattering detector, will probably overcome these sensitivity problems. [Pg.283]

The free oil can be determined by an ion exchange HPLC technique. A solution of the sample in ethyl alcohol is analysed by high-performance ion exchange chromatography using a specially prepared ion exchange resin stationary phase, ethanol mobile phase, and differential refractive index detection. [Pg.440]

The normalization method is the easiest and most straightforward to use but, unfortunately, it is also the least likely to be appropriate for most LC analyses. To be applicable, the detector must have the same response to all the components of the sample. An exceptional example, where the normalization procedure is frequently used, is in the analysis of polymers by exclusion chromatography using the refractive index detector. The refractive index of a specific polymer is a constant for all polymers of that type having more than 6 monomer units. Under these conditions normalization is the obvious quantitative method to use. [Pg.271]

Gel permeation chromatography studies using both refractive index and UV(260 nm) absorption detections have confirmed that both Acacia Senegal and Acacia seyal gums consist of three main components (Islam et al., 1997, Idris et al., 1998, Williams Phillips, 2000, Al Assaf 2006) ... [Pg.6]

Adsorption chromatography using small particle silica or alumina has also been employed in the separation of biologically meaningful substances. Phospholipids, for example, have been separated on silica (38). One of the big problems for such substances is detection, since many of the compounds are not U.V. active. Generally, the refractive index detector is employed for isocratic operation, and the moving wire detector for gradient operation. Formation of U.V.-active derivatives is also possible (39). [Pg.240]

Both recycled and non-recycled essential oils met the standards for specific gravity, angular rotation and refractive index of the Food Chemicals Codex [22] and United States Pharmacopeia [23] for cold-pressed lemon peel oil. Results of gas chromatography analysis show the same compounds and levels in both systems, specially for the oxygenated compounds as citral (neral and geranial). Therefore, recycling the aqueous discharges to the extractor does not cause undesirable modifications. [Pg.969]

It is important to know the influence of the physicochemical parameters of the mobile phase (dipole moment, dielectric constant, and refractive index) on solvent strength and selectivity. The main interactions in planar chromatography between the molecules of the mobile phases and those of solutes are caused by dispersion forces related to the refractive index, dipole-dipole forces related to the dipole moment, induction forces related to a permanent dipole and an induced one, hydrogen bonding, and dielectric interactions related to the dielectric constant. Solvent strength depends mainly on the dipole moment of the mobile phase, whereas the solvent selectivity depends on the dielectric constant of the mobile phase. [Pg.95]

Detection requirements in preparative-scale chromatography also differ from analytical erations where detectors are selected for their sensitivity. Sensitivity is not of overriding importance in preparative-scale chromatography the ability to accommodate large column flow rates and a wide linear response range are more useful. The sensitivity of the refractive index detector is usually quite adequate for prqtaratlve work but the ... [Pg.255]


See other pages where Chromatography refractive index is mentioned: [Pg.277]    [Pg.583]    [Pg.171]    [Pg.262]    [Pg.844]    [Pg.32]    [Pg.277]    [Pg.583]    [Pg.171]    [Pg.262]    [Pg.844]    [Pg.32]    [Pg.1287]    [Pg.585]    [Pg.261]    [Pg.693]    [Pg.54]    [Pg.68]    [Pg.134]    [Pg.270]    [Pg.181]    [Pg.317]    [Pg.24]    [Pg.260]    [Pg.556]    [Pg.284]    [Pg.445]    [Pg.493]    [Pg.309]    [Pg.465]    [Pg.498]    [Pg.598]    [Pg.242]    [Pg.217]    [Pg.296]    [Pg.302]    [Pg.442]   
See also in sourсe #XX -- [ Pg.101 ]




SEARCH



Chromatography (HPLC refractive index

Chromatography refractive index detectors

High performance liquid chromatography refractive index

High-performance liquid chromatography refractive-index detectors

Liquid chromatography refractive index detection

© 2024 chempedia.info