Chromatography HPLC refractive index

Figure 7.3. HPLC analysis of triglycerides in olive oil using nonaqueous reversed-phase chromatography with refractive index detection. Reprinted with permission from reference 11. Figure 7.3. HPLC analysis of triglycerides in olive oil using nonaqueous reversed-phase chromatography with refractive index detection. Reprinted with permission from reference 11.
Note Each of these instruments is equipped with full sets of columns, a computer, and printer. Abbreviations GPC, gel permeation chromatography HPLC, high-performance liquid chromatography RI, refractive index LS, light-scattering UV, ultraviolet, usually for measuring fluorescence vis, visible light. [Pg.122]

Thin-layer chromatography (TLC) is used both for characterization of alcohol sulfates and alcohol ether sulfates and for their analysis in mixtures. This technique, combined with the use of scanning densitometers, is a quantitative analytical method. TLC is preferred to HPLC in this case as anionic surfactants do not contain strong chromophores and the refractive index detector is of low sensitivity and not suitable for gradient elution. A recent development in HPLC detector technology, the evaporative light-scattering detector, will probably overcome these sensitivity problems. [Pg.283]

The free oil can be determined by an ion exchange HPLC technique. A solution of the sample in ethyl alcohol is analysed by high-performance ion exchange chromatography using a specially prepared ion exchange resin stationary phase, ethanol mobile phase, and differential refractive index detection. [Pg.440]

Advances in size-exclusion chromatography, coupled with refractive index, absorption, viscosity, and lightscattering detectors, and MALDI-ToFMS, have made it possible to accurately determine molecular weight distribution (oligomer profiling), even at the relatively low values of polymeric additives (up to about 5000 Da). Advances in column design, e.g. high-resolution PS/DVB columns (> 105 plates m-1) mean that SEC can provide a valuable alternative to conventional HPLC techniques for the separation of small molecules. [Pg.733]

Detection in 2DLC is the same as encountered in one-dimensional HPLC. A variety of detectors are presented in Table 5.2. The choice of detector is dependent on the molecule being detected, the problem being solved, and the separation mode used for the second dimension. If MS detection is utilized, then volatile buffers are typically used in the second-dimension separation. Ultraviolet detection is used for peptides, proteins, and any molecules that contain an appropriate chromophore. Evaporative light scattering detection has become popular for the analysis of polymers and surfactants that do not contain UV chromophores. Refractive index (RI) detection is generally used with size exclusion chromatography for the analysis of polymers. [Pg.109]

There are many HPLC detectors that can turn the presence of your compound into an electrical signal to be written on a chart recorder. Time was the refractive index detector was common. Clean eluent, used as a reference, went through one side of the detector, and the eluent with the samples went through the other side. A difference in the refractive index between the sample and reference caused an electrical signal to be generated and sent to a chart recorder. If you ve read the section on gas chromatography and looked ahead at infrared, you shouldn t be surprised to find both a sample and a reference. I did tell you the reference/sample pair is common in instrumentation. [Pg.250]

Separation and quantitation of carbohydrate mixtures may be achieved using HPLC, a method that does not necessitate the formation of a volatile derivative as in GLC. Both partition and ion-exchange techniques have been used with either ultraviolet or refractive index detectors. Partition chromatography is usually performed in the reverse phase mode using a chemically bonded stationary phase and acetonitrile (80 20) in 0.1 mol U1 acetic acid as the mobile phase. Anion- and cation-exchange resins have both been used. Carbohydrates... [Pg.340]

Experimental Techniques. Chromatography was performed on a Varian model 5060 HPLC equipped with a RI-3 refractive index detector. A Vista Plus Gel Permeation Chromatography (GPC) data system was used consisting of a Vista 401 chromatography data system serially connected to an Apple II microcomputer. The Vista 401 performs data acquisition and allows data storage and automations capability while all SEC data processing is performed on the Apple II by means of user-interactive GPC software for automated, on-line calibration and polymer analysis. [Pg.77]

Analytical Method Development for TRIS. The detection of brominated compounds of very low volatility such as TRIS posed special analytical problems. Since TRIS has no recognizable chromophore, the detection systems which are commonly used with high performance liquid chromatography (hplc), such as refractive index or short wavelength (<220 nm) uv detectors, are too non-specific to be of much practical use for the analysis of environmental samples. Furthermore, the sensitivities available with these detection methods are generally inadequate. [Pg.217]

As a result of advances in detection technology, newer HPLC detection techniques may be utilized. For example, evaporative light-scattering detection and refractive index detection may be used to quantify impurities with poor or no UV chromophore. Conductivity detection may also be used. In some cases, when no chromophore is present, chemical derivatization may be used to add a chromophore. Increasingly, tandem techniques such as liquid chromatography mass spectrometry (LC-MS) and GC-MS are utilized for impurity characterization. The highly selective nature of LC-MS ensures that few impurities are undetected. [Pg.12]

Measurements of the common physical constants such as boiling point or refractive index are not sufficiently sensitive to determine the trace amounts of impurities in question. Besides the common spectroscopic methods, techniques like gas chromatography (GC), high-pressure liquid chromatography (HPLC), or thin-layer chromatography (TLC) are useful. The surest criterion for the absence of interfering foreign compounds lies in the polymerization itself the purification is repeated until test polymerizations on the course of the reaction under standard conditions are reproducible (conversion-time curve, viscosity number of the polymers). [Pg.65]

Since the development of HPLC as a separation technique, considerable effort has been spent on the design and improvement of suitable detectors. The detector is perhaps the second-most important component of an HPLC system, after the column that performs the actual separation it would be pointless to perform any separation without some means of identifying the separated components. To this end, a number of analytical techniques have been employed to examine either samples taken from a fraction collector or the column effluent itself. Although many different physical principles have been examined for their potential as chromatography detectors, only four main types of detectors have obtained almost universal application, namely, ultraviolet (UV) absorbance, refractive index (RI), fluorescence, and conductivity detectors. Today, these detectors are used in about 80% of all separations. Newer varieties of detector such as the laser-induced fluorescence (LIE), electrochemical (EC), evaporative light scattering (ELS), and mass spectrometer (MS) detectors have been developed to meet the demands set by either specialized analyses or by miniaturization. [Pg.207]

While lactose may be determined by gas liquid chromatography, high performance liquid chromatography (HPLC), using a refractive index detector, is now usually used. [Pg.77]

High-performance liquid chromatography (HPLC) system with refractive index detector and HPLC column (e.g., Aminex HPX-87H, Bio-Rad) fitted with suitable guard column... [Pg.739]

A nonaqueous reversed-phase high-performance liquid chromatography (NARP-HPLC) with refractive index (RI) detection was described and used for palm olein and its fractions obtained at 12.5°C for 12-24 h by Swe et al. (101). The objective of their research was to find the optimum separation for analysis of palm olein triglycerides by NARP-HPLC, and to find a correction factor to be used in calculating CN and fatty acid composition (FAC). The NARP-HPLC method used to determine the triglyceride composition was modified from the method of Dong DiCesare (88). Palm olein was melted completely at 70°C in an oven for 30 min prior to crystal-... [Pg.219]

In situations where impurities have low or no UV chromophores, HPLC-NMR provides a unique window on the separation process. This has been exemplified using a drug substance known as SKF-99085, where HPLC-MS, HPLC-NMR, refractive index, light scattering and gas chromatography methods were all used to quantify and identify impurities [30] ... [Pg.58]

Fig. 4.3. High performance liquid chromatography (HPLC) of the monosaccharides obtained from a partially purified preparation of microbubble glycopeptide surfactant from forest soil. Following hydrolysis (in 2 N HC1 for 6 hr at 100°C) and filtration, the carbohydrate mixture was charged on a Bio-Rad HPX-87 cation exchange column. For comparison, part A shows the chromatogram (using the same HPLC column) of a standard solution, which contained 4 pg of each of three different monosaccharides (i.e., the last three peaks shown are glucose, xylose and fiicose, in the order of increasing retention times). Part B shows the chromatogram obtained from hydrolysis of the partially purified (see text) microbubble surfactant (approximately 30 pg). All other experimental conditions were identical in the two cases, i.e., water eluent, 0.5 ml/min flow rate, 85°C, refractive index detector attenuation -2x. (Taken from ref. 322.)... Fig. 4.3. High performance liquid chromatography (HPLC) of the monosaccharides obtained from a partially purified preparation of microbubble glycopeptide surfactant from forest soil. Following hydrolysis (in 2 N HC1 for 6 hr at 100°C) and filtration, the carbohydrate mixture was charged on a Bio-Rad HPX-87 cation exchange column. For comparison, part A shows the chromatogram (using the same HPLC column) of a standard solution, which contained 4 pg of each of three different monosaccharides (i.e., the last three peaks shown are glucose, xylose and fiicose, in the order of increasing retention times). Part B shows the chromatogram obtained from hydrolysis of the partially purified (see text) microbubble surfactant (approximately 30 pg). All other experimental conditions were identical in the two cases, i.e., water eluent, 0.5 ml/min flow rate, 85°C, refractive index detector attenuation -2x. (Taken from ref. 322.)...
HPLC units have been interfaced with a wide range of detection techniques (e.g. spectrophotometry, fluorimetry, refractive index measurement, voltammetry and conductance) but most of them only provide elution rate information. As with other forms of chromatography, for component identification, the retention parameters have to be compared with the behaviour of known chemical species. For organo-metallic species element-specific detectors (such as spectrometers which measure atomic absorption, atomic emission and atomic fluorescence) have proved quite useful. The state-of-the-art HPLC detection system is an inductively coupled plasma/MS unit. HPLC applications (in speciation studies) include determination of metal alkyls and aryls in oils, separation of soluble species of higher molecular weight, and separation of As111, Asv, mono-, di- and trimethyl arsonic acids. There are also procedures for separating mixtures of oxyanions of N, S or P. [Pg.18]

Gel permeation chromatography on dissolved irradiated and non-irradiated films (THF/water 99V/1V) was performed on a Waters HPLC apparatus equipped with both UV (280 nm) and refractive index detectors and with 4 microstyragel columns (105, 104, 103, 500). THF was used as eluent. The elution time was calibrated with polystyrene standards. The same concentrations were employed for... [Pg.63]


See other pages where Chromatography HPLC refractive index is mentioned: [Pg.585]    [Pg.243]    [Pg.1287]    [Pg.24]    [Pg.284]    [Pg.445]    [Pg.493]    [Pg.309]    [Pg.498]    [Pg.394]    [Pg.22]    [Pg.1663]    [Pg.301]    [Pg.118]    [Pg.230]    [Pg.72]    [Pg.492]    [Pg.561]    [Pg.171]    [Pg.22]    [Pg.23]    [Pg.360]    [Pg.262]    [Pg.500]    [Pg.394]    [Pg.177]    [Pg.45]    [Pg.85]   