Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Serial connection

Fig. 11. Particle size analyzer based on ultrasonic spectroscopy where DSP = digital signal processor, and RS 232 is a standard serial connection that allows... Fig. 11. Particle size analyzer based on ultrasonic spectroscopy where DSP = digital signal processor, and RS 232 is a standard serial connection that allows...
J. V. Hinshaw, Jr and L. S. Ettre, Selectivity tuning of serially connected open-tubular (capillary) columns in gas chromatography. Part 1 fundamental relationships , Chromatographia 21 561-572 (1986). [Pg.106]

Figure 8.17 Schematic diagram of a cross-section (a) tlvough the clamped plates, and views from above (b-d) of coupled plates serially connected to achieve multidimensional separation with stationary phases with different characteristics (hatched lines, glass plate light shading, stationary phase A dark shading, stationary phase B wavy lines, stationary phase C). Figure 8.17 Schematic diagram of a cross-section (a) tlvough the clamped plates, and views from above (b-d) of coupled plates serially connected to achieve multidimensional separation with stationary phases with different characteristics (hatched lines, glass plate light shading, stationary phase A dark shading, stationary phase B wavy lines, stationary phase C).
SERIALLY CONNECTED MULTILAYER FORCED-FLOW PLANAR CHROMATOGRAPHY... [Pg.188]

LD)-OPLC, involves the serial connection of the chromatographic plates. By application of this technique, it is also possible to use different stationary phases of decreasing polarity during a single development, as shown in Figure 8.18(a). [Pg.189]

The potential of serial connection of layers can be used for multidimensional planar chromatographic separations on different stationary phases of decreasing... [Pg.189]

Figure 8.18 Schematic diagrams showing (a) serially connected multilayer OPLC employing different types of stationaiy phase of decreasing polarity (A > B > C) as a type of MD-FFPC (b) fully off-line operational mode (c) fully on-line operational mode. Figure 8.18 Schematic diagrams showing (a) serially connected multilayer OPLC employing different types of stationaiy phase of decreasing polarity (A > B > C) as a type of MD-FFPC (b) fully off-line operational mode (c) fully on-line operational mode.
The total retention of a given solute and the gas holdup time of an unretained solute eluting through two serially connected columns is the sum of the retentions in the individual column units, and thus we can write that... [Pg.553]

The trial and error approach to optinizing a separation using serially connected columns can be Very time consuming. [Pg.554]

In this series of instruments for analytical electrochemistry, Philips also supplies the microprocessor-controlled PW 9527 digital conductivity meter with 16 push-buttons and on the rear an analogue output for connection to a recorder and a 25-way connector providing a two-way RS 232 serial connection (see Philips leaflet 9498 362 9326). [Pg.329]

The bipolar plate with multiple functions, also called a flow field plate or separation plate (separator), is one of fhe core components in fuel cells. In reality, like serially linked batteries, fuel cells are a serial connection or stacking of fuel cell unifs, or so-called unif cells fhis is why fuel cells are normally also called sfacks (Figure 5.1) [2]. The complicated large fuel cells or module can consist of a couple of serially connecfed simple fuel cells or cell rows. Excepf for the special unit cells at two ends of a simple stack or cell row, all the other unit cells have the same structure, shape, and functions. [Pg.308]

It is interesting to note that in chaotic regime, the flow rate outlet stream, which is manipulated by the control valve CVl (see Figure 12), and the reactor volume, are driven by the PI controller to the equilibrium point without chaotic oscillations. However, the other variables have a chaotic behavior as shown in Figure 18. So it is possible to obtain a reactor behavior, in which some variables are in steady state and the others are in regime of chaotic oscillations, due to the decoupling or serial connection phenomena. In this case the control system and the volumetric flow limitation of coolant flow rate through the control valve VC2, are the responsible of this behavior. Similar results can be obtained from model. [Pg.272]

Experimental Techniques. Chromatography was performed on a Varian model 5060 HPLC equipped with a RI-3 refractive index detector. A Vista Plus Gel Permeation Chromatography (GPC) data system was used consisting of a Vista 401 chromatography data system serially connected to an Apple II microcomputer. The Vista 401 performs data acquisition and allows data storage and automations capability while all SEC data processing is performed on the Apple II by means of user-interactive GPC software for automated, on-line calibration and polymer analysis. [Pg.77]

Whether sympathetic or parasympathetic, all efferent visceromotor nerves are made up of two serially connected neurons. The point of contact (synapse) between the first and second neurons occurs mainly in ganglia therefore, the first neuron is referred to as preganglionic and efferents of the second as postganglionic. [Pg.108]

The hypothalamic releasing hormones are peptides. They reach their target cells in the AH lobe by way of a portal vascular route consisting of two serially connected capillary beds. The first of these lies in the hypophyseal stalk, the second corresponds to the capillary bed of the AH lobe. Here, the hypothalamic hormones diffuse from the blood to their target cells, whose activity they control. Hormones released from the AH cells enter the blood, in which they are distributed to peripheral organs (1),... [Pg.242]

The experimental arrangement of LA-ICP-MS using a powerful laser ablation system coupled to a double-focusing sector field ICP-MS (Element, Thermo Fisher Scientific, Bremen) is shown in Figure 5.22. A cooled laser ablation chamber using two Peltier elements in serial connection... [Pg.151]

R 4] The micro structured mixer/reactor of the Forschungszentrum Karlsruhe (Figure 4.57) consists of a serial connection of five identical modules [68], Here modularity in the sense of using identical units stands more in the foreground than the supplier-specific assembly, which consists of different modules combined with a common base module as in the example above. [Pg.573]

In order to produce oxime 199 in greater quantities, the authors subsequently evaluated the use of DMF as the reaction solvent due to the increased solubility of the nitrite precursor 277 (36 mM). In conjunction with two serially connected microreactors, each containing 16 microchannels [1,000 pm (wide) x 500 pm (deep) x 1.0 m (length)] and eight black lights, the photochemical synthesis was performed continuously for 20h at a flow rate of 250 pi min 1 (residence time = 32 min). After an off-line aqueous extraction and silica gel column, 3.1 g of the oxime 199 was obtained equating to an isolated yield of 60% and successfully demonstrating the ability to use photochemical synthesis for the scalable preparation of pharmaceutically relevant compounds. [Pg.190]

Bolz S, Gotzenberger M, Knorr R, Lugert G, Siemens AG. Device and method for equalising the charge of serially connected capacitors belonging to a double layer capacitor. WO patent /2005/074092. [Pg.466]

Thus, the proposed model of the serial connection of the effective resistances, which correspond to the particles with the different types of conductivity satisfactorily describes the experimental results. [Pg.152]

High sensitivity DSC (HS-DSC) instruments are used to measure small heats of transition. They were developed originally for measuring to heat of denaturation of biopolymers in dilute solution (Hatakeyama and Quinn, 1994). The sensitivity of a heat flux instrument, for example, can be improved by increasing sample size, using multiple serially-connected thermocouples to measure both sample and reference temperatures, and increasing the heat sink capability of the heat flux plate (Hatakeyama and Quinn, 1994). [Pg.736]


See other pages where Serial connection is mentioned: [Pg.186]    [Pg.191]    [Pg.111]    [Pg.34]    [Pg.524]    [Pg.83]    [Pg.111]    [Pg.25]    [Pg.186]    [Pg.191]    [Pg.335]    [Pg.71]    [Pg.239]    [Pg.346]    [Pg.74]    [Pg.80]    [Pg.150]    [Pg.251]    [Pg.463]   


SEARCH



Connecting Serial Devices

Serially connected columns

© 2024 chempedia.info