The cathodic protection of reinforcing steel and stray current protection measures assume an extended electrical continuity through the reinforcing steel. This is mostly the case with rod-reinforced concrete structures however it should be verified by resistance measurements of the reinforcing network. To accomplish this, measuring cables should be connected to the reinforcing steel after removal of the concrete at different points widely separated from each other. To avoid contact resistances, the steel must be completely cleaned of rust at the contact points. [Pg.433]

In addition, with high solid content of the cooling water and at high flow velocities, severe corrosive conditions exist which continuously destroy surface films. Cathodic protection alone is not sufficient. Additional measures must be undertaken to promote the formation of a surface film. This is possible with iron anodes because the anodically produced hydrated iron oxide promotes surface film formation on copper. [Pg.469]

Interaction tests should be made on all unprotected structures in the vicinity of a proposed cathodic protection installation, and should be repeated annually or at some other suitable interval to ensure that alterations in the layout of plant or in the electrical conditions are taken into account. It is most convenient if the tests on all unprotected pipes or cables are made at the same time, the potential measurements being synchronised with the regular switching on and off of the protection current. It may then be convenient to continue with further tests to confirm that any remedial measures applied to one installation do not adversely affect other installations. [Pg.239]

Thermogalvanic corrosion is prevented by appropriate design and measures to avoid uneven heating/cooling and forming of hot spots. For heat-insulated pipes and equipment is important that the insulation is continuous. The corrosion form may under certain conditions be prevented by cathodic protection or coatings. [Pg.108]

Domestic or industrial hot-water heaters of galvanized steel through which hot aerated water passes continuously are not protected reliably in all types of water by nontoxic chemical additions such as silicates or polyphosphates. Adjustment of the saturation index to a more positive value, as discussed earlier, is sometimes helpful. Often, cathodic protection or use of nonferrous metals, such as copper or 70% Ni-Cu (Monel), is the best or only practical measure. [Pg.322]

The research on corrosion, started in this institute in the 1950s, continued successfully further. The intergranular corrosion of steels was measured by an electrochemical potentiodynamic reactivation method [310-312]. Since the 1960s, the passivity of brass was further studied, the rates of corrosion were measured by polarization resistance, the effect of deformation on anodic dissolution of steels was followed, and the surface roughness of metals was measured other subjects of research were, e.g., the behavior of passive films on steel, the effect of compositirai and motion of electrolyte on corrosion of passivated aluminum, the cathodic protection of passive metals against corrosion, the anodes for cathodic protection of steels, etc.[313-316]. Measurements of polarization resistance in the system iron—concentrated sulfuric acid or boiling nitric acid, of corrosion and matter... [Pg.27]

For the third step, if the determined total wall thickness (mechanical + CA) is not acceptable, great effort should be exercised to select and evaluate a suitable corrosion prevention measure to lower the required corrosion allowance. Some of these measures cannot withstand the process conditions, e.g. temperatures too high for polymer lining, no facilities for chemical injection, no continuous electrolyte for cathodic protection, and so on. [Pg.97]

Wherever possible, there should be a continuous secondary barrier for the entire pipeline system, in the form of jacket pipes, collecting basins, and channels. In some cases, this is not possible because it would impede cathodic corrosion protection or because differential expansion of the pipe and outer jacket threaten the systan. The secondary barrier can then only consist of intensive organizational and operative backup measures shorter inspection periods, shorter distances between shutoff points to limit possible losses, more elaborate provisions for leak detection, continual ronote monitoring of the pipeline systan, both internally and externally, equipment for tackling anergency events and catastrophes, contingency plans, and so forth. [Pg.642]

The potential control in anodic protection installations has two functions. First, the potential must be measured and compared to a desired preset value. Second, a control signal must then be sent to the power supply to force the dc current between the cathode and vessel wall. In early systems, this control function was done in an ON-OFF method because of the high costs of electronic drcuitiy. The recent progress in power electronics has resulted in all systems having a continuous proportional-fype control. Packaging these electronic components occasionally involves special requirements because most of the installations are made in chemical plants. Explosion-proof enclosures are sometimes required, and chemically resistant enclosures are necessary in other installations. [Pg.930]


See other pages where Cathodic protection continued measurements is mentioned: [Pg.261]    [Pg.261]    [Pg.472]    [Pg.647]    [Pg.171]    [Pg.257]    [Pg.676]    [Pg.225]    [Pg.226]    [Pg.351]    [Pg.472]    [Pg.550]    [Pg.704]    [Pg.432]    [Pg.436]    [Pg.626]    [Pg.888]    [Pg.272]    [Pg.241]    [Pg.218]    [Pg.168]    [Pg.245]    [Pg.218]    [Pg.301]    [Pg.174]    [Pg.22]    [Pg.373]    [Pg.276]    [Pg.283]    [Pg.312]    [Pg.256]   
See also in sourсe #XX -- [ Pg.10 , Pg.17 , Pg.18 , Pg.19 , Pg.36 ]

See also in sourсe #XX -- [ Pg.10 , Pg.17 , Pg.18 , Pg.19 , Pg.36 ]




SEARCH



Cathodic protection

Cathodic protection continued

Cathodic protection continued current measurement

Cathodic protection continued current-measuring

Cathodic protection continued potential measurement

Cathodic protection continued potential-measuring

Cathodic protection continued resistance-measuring

Cathodic protection continued resistivity measurements

Cathodic protection continued resistivity-measuring

Cathodic protection measuring

Cathodically protective

Continuous measurements

Measurement protection

Measures protection

Protective measures

© 2024 chempedia.info