Control signal

The bulk of hydrauhc fluids is specified and purchased on bid. Specifications and approval fists are issued by some manufacturers of hydraulic pumps and system components that require lubrication as well as power for control signal transmission. U.S. government military specifications for hydraulic fluids are fisted ia Table 12, and ASTM tests that are applicable to hydraulic fluids iaclude the foUowiag ... [Pg.269]

Various accessories can be suppHed along with the control valves for special situations. Positioners ensure that the valve stem is accurately positioned following small or slowly changing control signals or where unbalanced valve forces exist. Boosters, which are actually pneumatic amplifiers, can increase the speed of response or provide adequate force in high pressure appHcations. Limit switches are sometimes included to provide remote verification that the valve stem has actually moved to a particular position. [Pg.67]

Fig. 12. Cascade control signal flow diagram, where SPP = primary control variable setpoint PVP = primary control variable measurement ... Fig. 12. Cascade control signal flow diagram, where SPP = primary control variable setpoint PVP = primary control variable measurement ...
Control signals from individual distillation towers... [Pg.73]

By the very nature of batch processing, it is inevitable that process equipment will have idle time between batches. The idle time also could occur if the controller is not being used at all times during the execution of the batch (e.g., a flow controller may only be used during the feed of one of the reactants). During the idle time, control considerations such as reset windup must be considered to prevent the control signal from going outside of the control limits. [Pg.112]

The best anti-surge control is the simplest and most basic that will do the job. The most obvious parameter is minimum-flow measurement, or if there is a relatively steep pressure-flow characteristic, the differentia pressure may be used. The latter parameter allows for a much faster response system, as flow measurement response is generally slow however, the speed of response need only be fast enough to accept expected transients. One major problem with the conventional methods of measurement and control is the need to move the set point for initiation of the control signal away from the exact surge point to allow some safety factor for control response time and other parameters not directly included... [Pg.364]

In equation (4.68), T is called the integral action time, and is formally defined as The time interval in which the part of the control signal due to integral action increases by an amount equal to the part of the control signal due to proportional action when the error is unchanging . (BS 1523). [Pg.84]

Proportional control, gain A lfV/m) Control signal U s) = KfX is) - ZmCv))... [Pg.93]

Figure 10.9 assumes that the output window contains seven fuzzy sets with the same linguistic labels as the input fuzzy sets. If the universe of discourse for the control signal u(t) is 9, then the output window is as shown in Figure 10.10. [Pg.332]

Fig. 10.10 Seven set fuzzy output window for control signal (u). Fig. 10.10 Seven set fuzzy output window for control signal (u).
Defuzzification is the procedure for mapping from a set of inferred fuzzy control signals contained within a fuzzy output window to a non-fuzzy (crisp) control signal. The centre of area method is the most well known defuzzification technique, which in linguistic terms can be expressed as... [Pg.335]

Hence, for given error of 2.5, and a rate of change of error of —0.2, the control signal from the fuzzy controller is 3.83. [Pg.336]

Burns, R.S. (1995) The Use of Artificial Networks for the Intelligent Optimal Control of Surface Ships, IEEE Journal of Oceanic Engineering, 20(1) Special Issue Advanced Control Signal Processing for Oceanic Applications, 20(1), pp. 66-72. [Pg.428]

Shown on vessel with power pack and control signal... [Pg.7]

When the energy flows in and out of a compartment do not balance, the energy difference accumulates and the temperature increases or decreases. The changes in core and skin temperature then in turn alter the physiological control signals to restore balance and thermal stability. [Pg.179]

The complete LDA system includes the appropriate transmission and detection optoelectronics, traverse mechanisms, computer-controlled signal processing, and a data acquisition and evaluation system. The LDA equipment is a powerful tool for the measurement of flow velocity and velocity fluctuation, as well as the local concentration of particles or droplets transported in the airflow. [Pg.1170]


See other pages where Control signal is mentioned: [Pg.599]    [Pg.2824]    [Pg.389]    [Pg.430]    [Pg.67]    [Pg.71]    [Pg.72]    [Pg.72]    [Pg.373]    [Pg.785]    [Pg.787]    [Pg.2134]    [Pg.2487]    [Pg.108]    [Pg.339]    [Pg.450]    [Pg.10]    [Pg.309]    [Pg.253]    [Pg.9]    [Pg.9]    [Pg.93]    [Pg.97]    [Pg.334]    [Pg.335]    [Pg.336]    [Pg.336]    [Pg.338]    [Pg.373]    [Pg.132]    [Pg.109]    [Pg.775]   
See also in sourсe #XX -- [ Pg.6 , Pg.7 , Pg.9 , Pg.10 ]




SEARCH



Actuators electrical control signals

Amplification of Control Signals

Analogue control signal

BFCs Controlled by Logically Processed Biochemical Signals

Computer Control, Signal Detection and Amplification

Control danger signals

Control of the Input Signal

Control signal specification

Crisp control signal

Digital control signal

Electric control signals

Fatty acid desaturation signalling pathways controlling

PWM control signal

Pneumatic controllers signal transmission

Sensor Control and Signal Evaluation with Discrete Electronics

Signal transduction pathways controlling morphogenesis and haematopoiesis

Signal-controlled roundabouts

Signaling control mechanism

© 2024 chempedia.info