Nominal capacity, defined

The specified nominal capacity mostly defines the maximum capacity. [Pg.392]

In 1990, Giglioli et al. proposed a model valid for charge and discharge processes, with time variable current, and taking into account the thermal behavior of the battery (Figure 9.14) [35]. The nominal capacity is defined by... [Pg.263]

The discharge rate C is defined by the discharge current and the nominal capacity of the secondary cell. It is equal to the reciprocal value of the discharging time ... [Pg.17]

The nominal capacity of every system is defined by a specific value of C for example, for the nickel-cadmium system, it is Cj20. By discharging with a higher current, the final capacity obtainable becomes lower. [Pg.17]

Another important parameter for describing a secondary electrochemical cell is the achievable number of cycles or the lifetime. For economic and ecological reasons, systems with a high cycle life are preferred. The number of cycles indicates how often a secondary battery can be charged and discharged repeatedly before a lower limit (defined as a failure) of the capacity is reached. This value is often set at 80 percent of the nominal capacity. To compare different battery systems, besides the number of cycles, the depth of discharge must be quoted. [Pg.18]

The uncertainties of the aggregated scheduling problem are modeled by discrete scenarios. The demand scenarios are defined by random variations around a nominal profile where the variations represent new or changed orders. The scenarios for the uncertain capacity are generated by assuming the failure of one polymerization reactor with a certain probability for each period. [Pg.208]

Flow-through relief valves have traditionally been analyzed by treating the valve as a convergent noz-2ie [i 29.30] discharge coefficient (kactual mass flow rate to the theoretical ideal mass flow rate through a one-dimensional convergent nozzle of exit area equal to the nominal bore of the tested valve. Measured discharge coefficients are derated by 10% (Aidr) to specify valve capacity. [Pg.2430]

The rated or nominal capacity is the value for the Ah capacity given by the manufacturer at nominal operating conditions (defined by temperature, current, and end-of-discharge voltage). As a standard, the 10 h capacity (N = 10) should be used. A transformation between any temperature between 10 and 30°C and the nominal temperature is possible with the given equation. If the manufacturer only specifies values for the 100-h, 20-h, or 5-h capacity, then a rough approximation of the capacity can be gained from the rules-of-thumb ... [Pg.214]

The boiler is a product able to supply hot water in a central heating application. The appliance may be developed to provide the sanitary hot water. The performance parameters of the boiler are the nominal heating capacity in kW defined as full load mode and the nominal partial load capacity at 30% of nominal heating capacity. Tests are performed at standard conditions, which means supply plant temperatures outlet 80°C inlet 60°C and for condensing boilers, supply plant temperatures outlet 50°C and inlet 30°C. [Pg.718]

Bi e 82 = estimated bases for ESn e TDE .When ESn is equal to 120% or more of the nominal declared capacity of considered sector n, and the duration time of this overload (TDE ) is equal to 12 minutes, the respective Workload must be WL = 50 (Siewerdt E. 2003). For each value of sector capacity, there is a pair of bases 81 e 82, that in conjunction with ESn e TDEn, define the value of the instantaneous workload — 3VLinstantaneous of sector... [Pg.141]

Nominal capacity of MAC layer (B)—It is defined as the maximum achievable throughput at the MAC layer in one-hop network. It can be calculated as presented in (Jun (April) 2003). [Pg.2114]

The profile of the current entering into an SLI battery, and the evolution of the state of charge (SOC, defined in section 2.4.2) are shown qualitatively below (Figure 1.1). T q)ically, car batteries have a nominal voltage of 12 V. Their capacity is usually between 40 and 80 Ah. Start currents can... [Pg.4]

Instead of nominal capacity, the European standards define the assigned capacity, notated as C,. This is the minimum amount of electricity, indicated by the manufacturer, that a battery is capable of delivering in specific conditions after a complete recharge. It is this capacity which is indicated on a battery. However, in practice, documentation usually employs the term nominal capacity. [Pg.36]

For individual portable sealed lithium devices, the EOL is defined for a ratio of measured capacity to nominal capacity less than 60% (EN 61960 2004 which replaces lEC 61960 2003). [Pg.38]

The tests for qualification are performed by the manufacturer and can be defined as a type test, e.g., that a battery shall have 100% of the nominal capacity... [Pg.207]

The nominal capacity of valve-regulated batteries is defined between I5 and I20 according to the application and the technology of the battery. For definition the rated capacity following discharge rates is valid at T = 20°C ... [Pg.421]

Here E is still constant and R is defined in Equation 9.81. Given the large number of parameters of the proposed model, the complete identification of all of them is particularly complex. For discharge modeling only, the whole i-branch as well as Rp can be omitted. The dimensional parameters used in the expressions of and Rp vary a little among different batteries built with the same technology. When batteries of the same manufacturer in different models (and capacities) are considered, the parameters with the dimensions of a resistance can be taken in approximation as inversely proportional to the respective nominal capacities. [Pg.268]

In the liquid-level process presented in Chap. 1, the measurement h was defined as representing the fractional contents of the tank. This trick enabled us to find the time constant of the vessel in terms of its capacity V and its nominal throughput F. When instrumenting a plant, however, it is not necessary that every liquid-level transmitter be scaled to measure the entire volume of the vessel. If, instead, the transmitter span represents only a small percentage of the vessel volume, the vessel will have effectively shrunk to the span of the transmitter. To state it another way for control purposes, those parts of the vessel beyond the range of the transmitter do not exist. [Pg.45]

The battery shown in Figure 23.2 has a nominal voltage of 1.35 V and a nominal capacity of 1000 mA h defined for a load of 1250 Q, with a cut-off voltage of 0.9 V. For lighter loads, tests on early production batteries have given the results shown in Table 23.1. [Pg.267]


See other pages where Nominal capacity, defined is mentioned: [Pg.148]    [Pg.69]    [Pg.141]    [Pg.83]    [Pg.66]    [Pg.121]    [Pg.69]    [Pg.869]    [Pg.245]    [Pg.141]    [Pg.48]    [Pg.149]    [Pg.1272]    [Pg.195]    [Pg.199]    [Pg.35]    [Pg.797]    [Pg.285]    [Pg.197]    [Pg.207]    [Pg.200]    [Pg.708]    [Pg.940]    [Pg.28]    [Pg.7]    [Pg.534]   