Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Applications, resolution

Waterborne Epoxy Dispersions in Adhesive Applications, Resolution Performance Products LLC,... [Pg.288]

EPON 1124-A-80 425-443 Acetone solution Conventional brominated epoxy for FR-4 applications Resolution... [Pg.476]

So far in this chapter we have discussed the reactions of chiral compounds only with optically inactive reagents. Now let us turn to reactions with optically active reagents, and examine one of their most useful applications resolution of a racemic modification, that is, the separation of a racemic modification into enantiomers. [Pg.235]

ProUposome technologies have been introduced as a potentially applicable resolution to the stability problems of liposomes. Proliposomes are phospholipid preparations that generate liposomes by addition of aqueous phase and shaking. Proliposomes can be classified into two types particulate-based proliposomes [48] and solvent-based proliposomes [49],... [Pg.408]

Best applications Resolution of secondary alcohols, primary alcohols, hydrophoblc-water-Insoluble substrates. Amides, sterically hindered esters, polar substrate, synthesis of peptides... [Pg.128]

Systems, based on a method of inspection of slice by slice, in a number of cases allow to solve put problems. But for obtaining of higher resolution it is necessary to have an opportunity to increase number of inspected slices. It results in significant increasing of collection data time that is inadmissible in some applications. Besides this, the maximum allowable number of researched slices is rigidly limited by hardware opportunities of tomographs, and also by level of emission of x-ray sources. [Pg.216]

Application of experimental devices allows to perform NDT of products, made out of materials of low density (Al-Mg - alloys, Be, plastics) with high defectoscopic sensitivity up to 0,5 %. Inch-size X-ray vidicons used complete with microfocal X-ray tubes and X-ray image enlargement method allow to obtain resolution up to SO pairs of lines per mm. [Pg.449]

Recently commercially available X-ray systems for laminography have a spatial resolution limited to hundred microns, which is not enough for modem multilayer electronic devices and assembles. Modem PCBs, flip-chips, BGA-connections etc. can contain contacts and soldering points of 10 to 20 microns. The classical approach for industrial laminography in electronic applications is shown in Fig.2. [Pg.569]

Composite transducers will replace conventional transducers in applications where the improvement of test sensitivity, signal to noise ratio and axial resolution are mandatory. It must nevertheless also be noted in connection with the broadband feature that though composite probes have a specified nominal frequency, the echo signals allow no echo amplitude... [Pg.711]

Although the processing time unit basically could be further improved table 1 gives some idears what the achieved results and axial resolution mean in several interesting applications and low center frequencies. With low frequencies a lot of attenuation problems available in new engineered materials could be solved. [Pg.843]

Table 1 several applications, frequencies and thickness / depth resolution... [Pg.843]

The sample frequency of the ADC (analogue to digital converter) should be 8 times higher than the test frequency (centre frequency of the spectrum). In dependence of the application, different ADC- boards are used. A standard board (20520) provides 8 bit resolution and up to 100 Msamples/s in single shot mode. For manual tests, up to 400 Msamples/s can be reached in the repetition mode. For scanning systems with high frequencies boards up to 400 Msamples/s (single shot) are available. [Pg.858]

A recent design of the maximum bubble pressure instrument for measurement of dynamic surface tension allows resolution in the millisecond time frame [119, 120]. This was accomplished by increasing the system volume relative to that of the bubble and by using electric and acoustic sensors to track the bubble formation frequency. Miller and co-workers also assessed the hydrodynamic effects arising at short bubble formation times with experiments on very viscous liquids [121]. They proposed a correction procedure to improve reliability at short times. This technique is applicable to the study of surfactant and polymer adsorption from solution [101, 120]. [Pg.35]

A newer and perhaps more useful application of ellipsometry to Langmuir films is their lateral characterization via ellipsometric microscopy [146], A simple modification of the nuU ellipsometer allows one to image features down to 10-/im resolution. Working with a fixed polarizer and analyzer, some domains are at extinction while others are not and appear bright. This approach requires no fluorescent label and can be applied to systems on reflective supports. [Pg.129]

The resolution of this issue is based on the application of the Pauli exclusion principle and Femii-Dirac statistics. From the free electron model, the total electronic energy, U, can be written as... [Pg.128]

The field ion microscope (FIM) has been used to monitor surface self-diflfiision in real time. In the FIM, a sharp, crystalline tip is placed in a large electric field in a chamber filled with Fie gas [14]. At the tip. Fie ions are fonned, and then accelerated away from the tip. The angular distribution of the Fie ions provides a picture of the atoms at the tip with atomic resolution. In these images, it has been possible to monitor the diflfiision of a single adatom on a surface in real time [15]. The limitations of FIM, however, include its applicability only to metals, and the fact that the surfaces are limited to those that exist on a sharp tip, i.e. difhision along a large... [Pg.292]

One of the more recent advances in XPS is the development of photoelectron microscopy [ ]. By either focusing the incident x-ray beam, or by using electrostatic lenses to image a small spot on the sample, spatially-resolved XPS has become feasible. The limits to the spatial resolution are currently of the order of 1 pm, but are expected to improve. This teclmique has many teclmological applications. For example, the chemical makeup of micromechanical and microelectronic devices can be monitored on the scale of the device dimensions. [Pg.308]

Other than the obvious advantages of reduced fluorescence and high resolution, FT Raman is fast, safe and requires mmimal skill, making it a popular analytic tool for the characterization of organic compounds, polymers, inorganic materials and surfaces and has been employed in many biological applications [41]. [Pg.1200]


See other pages where Applications, resolution is mentioned: [Pg.199]    [Pg.251]    [Pg.392]    [Pg.372]    [Pg.136]    [Pg.199]    [Pg.251]    [Pg.392]    [Pg.372]    [Pg.136]    [Pg.206]    [Pg.208]    [Pg.224]    [Pg.365]    [Pg.439]    [Pg.443]    [Pg.459]    [Pg.469]    [Pg.472]    [Pg.472]    [Pg.505]    [Pg.507]    [Pg.697]    [Pg.708]    [Pg.711]    [Pg.856]    [Pg.1061]    [Pg.873]    [Pg.1021]    [Pg.1209]    [Pg.1233]    [Pg.1248]    [Pg.1283]    [Pg.1296]   
See also in sourсe #XX -- [ Pg.18 ]




SEARCH



Antibody 38C2-Catalyzed Retro-aldol Reactions and their Application to Kinetic Resolution

Application of High-Resolution NMR

Application of Low-Resolution NMR for Simultaneous Moisture and Oil Determination in Food (Oilseeds)

Applications dynamic kinetic resolution

Applications of Dynamic Kinetic Resolution

Applications of high-resolution solid-state NMR

Applications of high-resolution solid-state NMR spectroscopy

High resolution applications

High-resolution NMR chemometric applications

High-resolution mass spectrometry environmental applications

Liquid chromatography—high-resolution applications

Some Applications of Kinetic Resolution

Ultrahigh-resolution applications

© 2024 chempedia.info