Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Analysis Method

Analysis of binding experiments required a careful comparison of (i) the MYKO 63 bands, either in the presence or absence of DNA bands and (ii) the DNA Raman bands, either in the presence or absence of MYKO 63 bands. This comparison was achieved by computer-subtracting variable amounts of one spectrum from another. Previously, the various spectra were normalized to the same relative Raman intensity, with the 934 cm band (CIO symmetric stretch) as an internal standard. The intensity of the CIO. scattering measures the combined effect of such experimental factors as counting time, optical alignment and laser power. [Pg.34]

Comparison of the complete spectra of the solvent (10 mM NaClO in water) and of the solutions (MYKO 63 or MYKO 63-DNA in the solvent) showed that the region around 1850 cm can be considered to have nearly zero Raman intensity at least for the lower wave numbers. Thus, for each spectrum, a horizontal base-line is drawn from this point, then the solvent spectrum is subtracted taking into account a coefficient determined from the compound concentration of the solution in order to keep the horizontal base-line unchanged for the new spectrum. [Pg.34]

For comparison of bound and unbound DNA (see Figs. 27 and 28) the procedure was performed in the same way. The spectrum of partially bound DNA was obtained by subtracting the free MYKO difference spectrum (Fig. 26A) from the spectrum of MYKO-DNA complex (Fig. 27, set I and Fig. 28, set II). [Pg.35]

Raman scattering were obtained for the first time for NjPjAzg and for NjPjAzg-DNA complexes (sets I and II). [Pg.35]

During the study of N3P3AZ6-DNA complexes by the Scatchard technique it was shown that an incubation time of at least 5 days is necessary after mixing the MYKO 63 with DNA on Day D before complete interaction is observed. These results are clearly confirmed by the present work as no fundamental discrepancy was observed between the spectra of the free and bound MYKO 63 when the latter was deduced from the recorded spectrum of the MYKO 63-DNA complex on Day (D -h 1). [Pg.37]

The reference method most commonly used to test other analysis methods and historically used to analyze lead in samples is the dithizone complexiometric method. In this method, a dithizone-lead complex is formed, which has a broad and intense absorption peak at 510 nm [53]. Quantitative, precise results can be obtained when care is taken in sample and reference preparation. Advantages of the dithizone complexiometric method include simple and relatively inexpensive equipment, linear absorption to lead concentration, need for only a small sample, adaptability to large samples, and ready removal of interferances [73]. [Pg.10]

Atomic absorption (AA) spectrometry is a generally accepted method for the analysis of many metals [74]. In a typical A A method, a liquid sample is aspirated into a flame, where ions within the liquid are reduced to the atomic state. The metals in the atomic state can then quantitatively absorb light at the wavelengths characteristic of their resonance frequencies, 217.0 and 283.3 nm for lead. Alternately, the ions may either be chemically reduced by a cold vapor technique [32] or be thermally reduced in a graphite furnace before analysis, which usually gives better sensitivities than flame AA (as low as 50 pg/kg). [Pg.10]

Several hundred samples can be analyzed in a work day if the samples are already prepared. In flame techniques and cold vapor techniques, the sample must be in solution. Procedures for solution of some samples may be time consuming. Use of a graphite furnace for sample reduction eliminates many problems in sample preparation. [Pg.10]

Anodic stripping voltammetry is an electroanalytical analysis method, that can be employed in the study of many metals [74]. Lead is analyzed by selective deposition on an electrode (reduction) to facilitate concentration. The lead is then stripped (oxidized) by a linearly variable applied voltage, with the output being a plot of current and voltage in which peak area corresponds to the oxidation of lead. The method is accurate and reliable to the 1 pg/L level [73]. [Pg.10]

Optical emission spectroscopy includes the observation of flame-, arc-, and spark-induced emission phenomena in the ultraviolet, visible, and near infrared regions of the electromagnetic spectrum [38]. Qualitative and quantitative information can be gained from the intensity of the characteristic emission wavelengths. Analysis of lead in environmental samples (e.g., soils, rocks, and minerals) may be performed reproducibly down to the 5 ppm level. Emission spectroscopy is best used for the multi-elemental analysis of samples, because of the high cost of equipment. Usually, single element analyses are not performed on a emission spectrograph. [Pg.11]

The output from gravitational wave detectors is generally time series data that provide a direct measure of the strain on the detector. Extraction of the gravitational wave signal is frustrated by noise which limits the sensitivity of the instrument. If the calibrated strain signal from a given detector is h(t), the detector sensitivity can be expressed in terms of the mean square instrumental noise per unit frequency. Specifically, the noise power spectral density of the instrumental strain noise is [Pg.99]

TABLE III Physical Data for Modern Ground-Based Interferometrio Detectors [Pg.100]


Stone A J and Alderton M 1985 Distributed multipole analysis—methods and applications Mol. Phys. 56 1047... [Pg.216]

The disadvantage of TPD is that, in order to derive the kinetie parameters, rather involved eomputations are neeessary [21, 24]. As an alternative to the eomplete desorption analysis, many authors rely on simplified methods. The analysis of speetra using simplified analysis should be made with eare, as simplified analysis methods may easily give erroneous results [21]. [Pg.1864]

The essential slow modes of a protein during a simulation accounting for most of its conformational variability can often be described by only a few principal components. Comparison of PGA with NMA for a 200 ps simulation of bovine pancreatic trypsic inhibitor showed that the variation in the first principal components was twice as high as expected from normal mode analy-si.s ([Hayward et al. 1994]). The so-called essential dynamics analysis method ([Amadei et al. 1993]) is a related method and will not be discussed here. [Pg.73]

To enable the application of electronic data analysis methods, the chemical structures have to be coded as vectors see Chapter 8). Thus, a chemical data set consists of data vectors, where each vector, i.e., each data object, represents one chemical structure. [Pg.443]

Sections 9A.2-9A.6 introduce different multivariate data analysis methods, including Multiple Linear Regression (MLR), Principal Component Analysis (PCA), Principal Component Regression (PCR) and Partial Least Squares regression (PLS). [Pg.444]

The electronic data analysis service (ELECTRAS), which was developed at the Com-puter-Chemie-Centrum of the University of Erlangen-Ntlmberg through a project supported by the DFN-Verein and the BMBF, is a web-based application which presents an interface to various kinds of data analysis methods. It offers the methods... [Pg.449]

An additional feature of ELECTRAS is a module which provides an introduction to various data analysis techniques One part of this module provides a typical work flow for data analysis. It explains the important steps when conducting a data analysis and describes the output of the data analysis methods. The second part gives a description of the methods offered. This modvJe can be used both as a guideline for novice users and as a reference for experts. [Pg.452]

Distributed multipole models for Nj and HF. (Figure adapted from Stone A j and M Alderton 19S5. ibuted Multipole Analysis Methods and Applications. Molecular Physics 56 3 047-1064.)... [Pg.214]

The Fermi contact density is defined as the electron density at the nucleus of an atom. This is important due to its relationship to analysis methods dependent... [Pg.110]

Q-Chem includes HF, ROHF, UHF, and MP2 Hamiltonians as well as a good selection of DFT functionals. Mulliken and NBO population analysis methods are available. Multiple options are available for SCF convergence, geometry optimization, and initial guess. IR and Raman intensities can also be computed. In addition, the documentation was well written. [Pg.340]

The magnitude of a method s relative error depends on how accurately the signal is measured, how accurately the value of k in equations 3.1 or 3.2 is known, and the ease of handling the sample without loss or contamination. In general, total analysis methods produce results of high accuracy, and concentration methods range from high to low accuracy. A more detailed discussion of accuracy is presented in Chapter 4. [Pg.39]

Suppose that for a particular total analysis method the signal is a measurement of mass using a balance whose smallest increment is 0.0001 g. If the method s... [Pg.39]

In a typical total analysis method, the procedure might read... [Pg.51]

Keith, L. H., ed. Compilation ofEPA s Sampling and Analysis Methods, Lewis Boca Raton, 1996. [Pg.52]

Despite the variety of methods that had been developed, by 1960 kinetic methods were no longer in common use. The principal limitation to a broader acceptance of chemical kinetic methods was their greater susceptibility to errors from uncontrolled or poorly controlled variables, such as temperature and pH, and the presence of interferents that activate or inhibit catalytic reactions. Many of these limitations, however, were overcome during the 1960s, 1970s, and 1980s with the development of improved instrumentation and data analysis methods compensating for these errors. ... [Pg.624]

Duarte and colleagues used a factorial design to optimize a flow injection analysis method for determining penicillin potentiometricallyd Three factors were studied—reactor length, carrier flow rate, and sample volume, with the high and low values summarized in the following table. [Pg.702]

Analysis of Surface Elemental Composition. A very important class of surface analysis methods derives from the desire to understand what elements reside at the surface or in the near-surface region of a material. The most common techniques used for deterrnination of elemental composition are the electron spectroscopies in which electrons or x-rays are used to stimulate either electron or x-ray emission from the atoms in the surface (or near-surface region) of the sample. These electrons or x-rays are emitted with energies characteristic of the energy levels of the atoms from which they came, and therefore, contain elemental information about the surface. Only the most important electron spectroscopies will be discussed here, although an array of techniques based on either the excitation of surfaces with or the collection of electrons from the surface have been developed for the elucidation of specific information about surfaces and interfaces. [Pg.274]

D. J. Coimor, B. A. Sexton, and R. St. C. Smart, eds., Suface Analysis Methods in Materials Science, Springer Series in Suface Sciences, Vol. 23,... [Pg.288]

Anhydrous hydrogen fluoride is also available in cylinders, and aqueous hydrogen fluoride, either 50% or 70%, is also shipped in polyethylene bottles and carboys. Typical product specifications and analysis methods are given in Table 4. [Pg.197]

Oxidation of a glycol can lead to a variety of products. Periodic acid quantitatively cleaves 1,2-glycols to aldehydes and is used as an analysis method for glycols (12,13). The oxidation of propylene glycol over Pd/C modified with Pb, Bi, or Te forms a mixture of lactic acid, hydroxyacetone, and pymvic acid (14). Air oxidation of propylene glycol using an electrolytic crystalline silver catalyst yields pymvic aldehyde. [Pg.366]

There are three heat-transfer modes, ie, conduction, convection, and radiation, each of which may play a role in the selection of a heat exchanger for a particular appHcation. The basic design principles of heat exchangers are also important, as are the analysis methods employed to determine the right size heat exchanger. [Pg.481]

Entrance andExit SpanXireas. The thermal design methods presented assume that the temperature of the sheUside fluid at the entrance end of aU tubes is uniform and the same as the inlet temperature, except for cross-flow heat exchangers. This phenomenon results from the one-dimensional analysis method used in the development of the design equations. In reaUty, the temperature of the sheUside fluid away from the bundle entrance is different from the inlet temperature because heat transfer takes place between the sheUside and tubeside fluids, as the sheUside fluid flows over the tubes to reach the region away from the bundle entrance in the entrance span of the tube bundle. A similar effect takes place in the exit span of the tube bundle (12). [Pg.489]

Numerous collections of herbicide analysis methods have been pubUshed (276—279). An increased emphasis has been placed on the first step in the environmental sampling process, that of obtaining a representative, uncontaminated sample. If this is to be accompUshed, consideration must be made of such factors as sample size and location (280—283). After the sample has been obtained, it must be stored in such a way as to minimize degradation. This generally consists of refrigeration, possibly preceded by some type of drying (284). [Pg.49]


See other pages where Analysis Method is mentioned: [Pg.195]    [Pg.65]    [Pg.66]    [Pg.263]    [Pg.1824]    [Pg.63]    [Pg.440]    [Pg.99]    [Pg.207]    [Pg.39]    [Pg.39]    [Pg.40]    [Pg.40]    [Pg.43]    [Pg.45]    [Pg.45]    [Pg.47]    [Pg.58]    [Pg.264]    [Pg.538]    [Pg.640]    [Pg.663]    [Pg.268]    [Pg.220]    [Pg.191]   
See also in sourсe #XX -- [ Pg.17 ]

See also in sourсe #XX -- [ Pg.147 ]




SEARCH



© 2019 chempedia.info