Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Population Analysis Methods

Assume an experiment in which a group of subjects selected to represent a spectrum of severity of some condition (e.g., renal insufficiency) is given a dose of drug, and drug concentrations are measured in blood samples collected at intervals after dosing. The structural kinetic models used when performing a population analysis do not differ at all from those used for analysis of data from an individual patient. One still needs a model for the relationship of concentration to dose and time, and this relationship does not depend on whether the fixed-effect parameter changes [Pg.131]

The advantages of this method are its simplicity, familiarity, and the fact that it can be used with sparse data and differing numbers of data points per individual. The disadvantages are that it is not possible to determine the fixed-effect sources of inter individual variability, such as creatinine clearance (CLcr). It also cannot distinguish between variability within and between individuals, and an imbalance between individuals results in biased parameter estimates. [Pg.131]

The intercept in this equation provides an estimate of nonrenal clearance. [Pg.132]

The advantages of this method are that it is easy and most investigators are familiar with it. Because parameters are estimated for each individual, these [Pg.132]

FIGURE 10.2 Fit obtained using a one-compartment model to fit plasma concentration-vs-time data observed following intravenous bolus administration of a drug. Each panel represents an individual patient. [Pg.132]


Q-Chem includes HF, ROHF, UHF, and MP2 Hamiltonians as well as a good selection of DFT functionals. Mulliken and NBO population analysis methods are available. Multiple options are available for SCF convergence, geometry optimization, and initial guess. IR and Raman intensities can also be computed. In addition, the documentation was well written. [Pg.340]

Following Vincent and Radom s comprehensive ab initio study (1978), Escudero et al. (1985) also performed ab initio calculations at the STO-3G level for seven 4-substituted benzenediazonium ions. For the unsubstituted benzenediazonium ion, the optimized geometries are the same as in Figure 4-1 (I). For charge density calculations another population analysis method was used (Escudero and Yanez, 1982), and this gave results different from those of Vincent and Radom. However,... [Pg.86]

In these examples, the condensed Fukui functions were computed using Hirsh-feld population analysis [26], which is unique among the commonly employed population analysis methods, because the same results are obtained from the response of molecular fragment and the fragment of molecular response approaches [24]. There are other arguments in favor of the Hirshfeld scheme too [27,28], many of them based on the tendency for the atom-condensed Hirshfeld Fukui functions to be nonnegative [25,29,30]. Nonetheless, condensed Fukui functions maybe computed using any population analysis method common methods... [Pg.261]

Using a population analysis method, an atom-localized version of the Fukui functions is defined as [Yang and Mortier, 1986] ... [Pg.361]

Until recently the primary interest in the electronic stmcture calculations has been to derive partial charges on the imidazohum cation for use in classical simulations [11,13,14,16,62,83]. The charge distribution however depends strongly on the method of analysis. The Natural Atomic Orbital (NAO) [84-88] and MuUiken population analysis methods have been apphed to the imidazolium cations [16,64]. A number of methods have been used to determine partial charges from the electrostatic potential these also show significant variation. There is an especially large... [Pg.218]

By looking at the maximum localized Wannier functions and using different population analysis methods. Buhl et al. suggested that there is a donor-acceptor interaction between the lone pairs of Q and the anti-bonding population analysis revealed that the amount of charge transferred from anions to cations ( 0.2 5e) fluctuated very little during the M D trajectory. [Pg.243]

The population analysis methods use all the available data to estimate the population. The best estimates for the parameters of an individual study are only obtained after the population distribution has been estimated by Bayesian estimation. Essentially, the various methods estimate the population parameters d in h(fi,6 ). The methods differ primarily in the form that h(fi,6jc) is assumed to have. Despite the fact that all arrive at a quantitative description of h(fi,Ooc), the different forms have been divided into parametric, semiparametric, and nonparametric. Each of these will be described. [Pg.274]

The CHelpG population analysis method implemented in Gaussian 09 was used to calculate Merz-Kollman atomic charges [27, 40] for each atom within the optimized diene reactant states as described above. [Pg.238]


See other pages where Population Analysis Methods is mentioned: [Pg.207]    [Pg.440]    [Pg.315]    [Pg.2509]    [Pg.57]    [Pg.59]    [Pg.131]    [Pg.2950]    [Pg.63]    [Pg.271]    [Pg.414]    [Pg.414]    [Pg.226]    [Pg.79]    [Pg.189]    [Pg.99]    [Pg.211]    [Pg.272]    [Pg.342]    [Pg.4]    [Pg.440]    [Pg.17]    [Pg.248]    [Pg.2509]    [Pg.46]    [Pg.414]    [Pg.414]    [Pg.847]    [Pg.1792]    [Pg.1793]    [Pg.229]    [Pg.229]    [Pg.214]    [Pg.216]    [Pg.219]    [Pg.220]   


SEARCH



Population Analyses for Semiempirical Methods

Population analyses, semiempirical methods

Population analysis

Population methods

Population pharmacokinetics analysis methods

© 2024 chempedia.info