Analysis evolving gases

Evolved Gas Detection iEGD). This term covers any technique of detecting whether or not a volatile product is formed during thermal analysis. Evolved Gas. 4 mi lysis (EG.4). A technique of determining the nature and amount of volatile product or products formed during thermal analysis. [Pg.461]

There have been few reviews of the topic as a whole and only one book dedicated to it. The technique is, however, widely used, though the subject matter is dispersed through the literature, and not readily found. There seems to be a problem in correct choice of keywords the official Chemical Abstracts term, thermal analysis - evolved gas , is rarely used, and searches using this are disappointing. [Pg.174]

Thermogravimetric analysis Differential thermal analysis Differential scanning calorimetry Thermal volatiUszation analysis Evolved gas analysis Mass spectroscopy methods Matrix-assisted laser desorption/ionization Imaging chemiluminescence... [Pg.154]

Kitahara Y, Takahashi S, Kuiamoto N, Sala M, Tsugoshi T, Sablier M, Fujii T. Ion attachment mass spectrometry combined with infrared image furnace for thermal analysis evolved gas analysis studies. Anal Chem. 2009 81 3155-8. [Pg.201]

Evolutionary technology Evolved gas analysis Ewens-Bassett numbers... [Pg.387]

Measurements of product gas evolution, mass loss or evolved gas analysis may all be used to study the kinetics of a solid—solid interaction provided that there is strict adherence to the condition that gas evolution occurs concurrently with the solid state process. Clearly this approach is only applicable if there is direct experimental support for a single step process. For example, carbon dioxide release is identified [410] as being... [Pg.37]

Thermal-programmed solid insertion probe mass spectrometry (TP-SIP-MS) has been proposed [247,248], in which the solid insertion probe consisting of a water-cooled microfumace enters the mass spectrometer via an airlock. The sample is contained in a small Pyrex tube (i.d. 1 mm, length 20 mm). The TIC trace gives a characteristic evolved gas profile for each compound in a mixture of materials, and the mass spectra associated with each TIC peak give a positive identification of that component as it is vaporised. TP-SIP-MS is appropriate for analysis of small solid particles which are volatile, or produce volatile decomposition products. The technique is a form of evolved gas analysis. [Pg.410]

Although the majority of studies focus on the solid state, many applications focus more or additionally on the volatile products arising from polymer degradation. Evolved gas analysis (EGA) from thermal analysers and pyrolysers by spectroscopic and coupled chromatography-spectroscopy techniques can be particularly important from a safety and hazard viewpoint, since data from such measurements can be used to predict toxic or polluting gases from fires, incinerators, etc. [Pg.389]

A thorough study of the mechanism of degradation of several fire retardant melamine salts is carried out using thermogravimetry, evolved gas analysis and spectroscopic characterisation of the products of degradation. [Pg.211]

The ability of the new precursors to decompose thermally to yield singlephase CIS was investigated by powder XRD analysis and EDS on the nonvolatile solids from the TGA experiments of selected compounds. Furthermore, using TGA-evolved gas analysis (EGA), the volatile components from the degradation of the SSPs could be analyzed via real-time fourier transform infrared (FTIR) and mass spectrometry (MS), thus providing information for the decomposition mechanism.3 The real-time FTIR spectrum for 7 and 8 shows absorptions at approximately 3000,1460,1390,1300, and 1250 cm-1 (see Fig. 6.7). [Pg.166]

Evolved gas analysis (EGA) is based on the study of gases or volatile breakdown products emitted by a sample on heating. The identity and properties of the volatile materials emitted serve as a basis for the analysis of the sample. One particular technique of EGA which has attracted sub-... [Pg.497]

Evolved gas analysis (ega), 14 234 Ewens-Bassett numbers, 17 391, 392 Examiners citations, 18 237, 238 Exanta, 4 100t, 102 Excess properties, ideal mixture and,... [Pg.339]

This is the primary degradation process accompanying processing of the polymer. The early stage of the dehydrochlorination process is uncomplicated by interfering processes. The only product observed by evolved gas analysis is hydrogen chloride (scheme 1). The sample... [Pg.274]

Air Adsorb to qnartz filter Evolved Gas Analysis 10-g NR Daisey and Gnndel 1991... [Pg.147]


See other pages where Analysis evolving gases is mentioned: [Pg.290]    [Pg.298]    [Pg.176]    [Pg.149]    [Pg.113]    [Pg.21]    [Pg.329]    [Pg.36]    [Pg.436]    [Pg.102]    [Pg.105]    [Pg.753]    [Pg.757]    [Pg.9]    [Pg.70]    [Pg.70]    [Pg.79]    [Pg.223]    [Pg.249]    [Pg.215]    [Pg.192]    [Pg.115]    [Pg.382]    [Pg.174]    [Pg.128]    [Pg.146]    [Pg.176]   
See also in sourсe #XX -- [ Pg.13 ]




SEARCH



Analysis of Evolving Gases from Polymers

Evolvability

Evolved gas analysis

Evolved gas analysis

Evolved gas analysis, EGA

G4 Evolved gas analysis

Gas Evolving

Gases analysis

Hyphenated TGA techniques and evolved gas analysis