Wide range samples

The second field of application involves the occasional analysis of wide range samples. In this category we find samples which only occur in the laboratory occasionally and in small numbers, so that only a small number of chromatographic analyses have to be performed. For samples of this kind it is usually sufficient to realize a separation and it is not rewarding to try and optimize the selectivity, not even if the analysis time is rather long and the required number of plates high. [Pg.256]

The pattern of the variation of retention with composition in LC is affected by the choice of both the stationary and the mobile phase. The optimum shape of the gradient for unknown wide range samples is dictated by the phase system. Linear or slightly convex gradients are optimal for RPLC. Concave gradients are optimal for LSC. [Pg.266]

An important application of this type of analysis is in the determination of the calculated cetane index. The procedure is as follows the cetane number is measured using the standard CFR engine method for a large number of gas oil samples covering a wide range of chemical compositions. It was shown that this measured number is a linear combination of chemical family concentrations as determined by the D 2425 method. An example of the correlation obtained is given in Figure 3.3. [Pg.52]

Clearly, the physical chemistry of surfaces covers a wide range of topics. Most of these subjects are sampled in this book, with emphasis on fundamentals and important theoretical models. With each topic there is annotation of current literature with citations often chosen because they contain bibliographies that will provide detailed source material. We aim to whet the reader s appetite for surface physical chemistry and to provide the tools for basic understanding of these challenging and interesting problems. [Pg.3]

Once the above restrictions on isotope, solubility, chemical lability and paramagnetism are met, then a very wide range of samples can be investigated. Gases can be studied, especially at higher pressures. Solutions for... [Pg.1439]

Even when well defined model systems are used, colloids are ratlier complex, when compared witli pure molecular compounds, for instance. As a result, one often has to resort to a wide range of characterization teclmiques to obtain a sufficiently comprehensive description of a sample being studied. This section lists some of tire most common teclmiques used for studying colloidal suspensions. Some of tliese teclmiques are discussed in detail elsewhere in tliis volume and will only be mentioned in passing. A few teclmiques tliat are relevant more specifically for colloids are introduced very briefly here, and a few advanced teclmiques are highlighted. [Pg.2671]

A possible explanation of the hysteresis could be the non-equilibrium of the DNA hydration. In that case the value of hysteresis has to depend on the size of the experimental sample. However, such a dependence is not observed in the wide range of DNA film thicknesses (0.05-0.2 fmi) [14], [12]. Thus, hysteresis cannot be a macroscopic phenomenon and does reflect the molecular interaction of water and the biopolymer. [Pg.117]

As already mentioned, the choice of the supercooled liquid as reference state has been questioned by some workers who use the saturation vapour pressure of the solid, which is measured at the working temperature in the course of the isotherm determination. The effect of this alternative choice of p° on the value of a for argon adsorbed on a number of oxide samples, covering a wide range of surface areas, is clear from Table 2.11 the average value of is seen to be somewhat higher, i.e. 18 OA. ... [Pg.76]

The comparison plot offers a particularly simple and direct means of comparing the shapes of a pair of isotherms but for more general applications which involve a numt>er of samples of a solid covering a wide range of specific surface, the a,-method is preferable. The j-curve represents a convenient way of recording and using the reference isotherm. [Pg.100]

In Unger and Fischer s study of the effect of mercury intrusion on structure, three samples of porous silica were specially prepared from spherical particles 100-200 pm in diameter so as to provide a wide range of porosity (Table 3.16). The initial pore volume n (EtOH) was determined by ethanol titration (see next paragraph). The pore volume u (Hg, i) obtained from the first penetration of mercury agreed moderately well with u fEtOH),... [Pg.182]

Thus the m/z value for such ions is [M -i- n-l]/n, if the mass of hydrogen is taken to be one. As a particular example, suppose M = 10,000. Under straightforward Cl conditions, [M + H]+ ions will give an m/z value of 10,001/1 = 10,001, a mass that is difficult to measure with any accuracy. In electrospray, the sample substance can be associated with, for example, 20 hydrogens. Now the ion has a mass-to-change ratio of [M -t 20-H] and therefore m/z = 10,020/20 = 501. This mass is easy to measure accurately with a wide range of instruments. [Pg.57]

If a sample solution is introduced into the center of the plasma, the constituent molecules are bombarded by the energetic atoms, ions, electrons, and even photons from the plasma itself. Under these vigorous conditions, sample molecules are both ionized and fragmented repeatedly until only their constituent elemental atoms or ions survive. The ions are drawn off into a mass analyzer for measurement of abundances and mJz values. Plasma torches provide a powerful method for introducing and ionizing a wide range of sample types into a mass spectrometer (inductively coupled plasma mass spectrometry, ICP/MS). [Pg.87]

Isotopic dilution analysis is widely used to determine the amounts of trace elements in a wide range of samples. The technique involves the addition to any sample of a known quantity (a spike) of an isotope of the element to be analyzed. By measuring isotope ratios in the sample before and after addition of the spike, the amount of the trace element can be determined with high accuracy. The method is described more fully in Figure 48.13. [Pg.366]

M is a small fractional order, this can amount to a considerable effect over a wide range of M values. For example, in the limit described in item (2), where a a, two samples of the same polymer showing a 1000-fold range of M will differ in a—as well as and (rg /M) -by a factor of 2. This... [Pg.621]

Agricultural Uses. Pesticides represent the second largest commercial market for hydrazine. Hundreds of hydrazine derivatives have been patented for a wide range of agricultural appHcations. Table 13 presents a sampling of the 50—60 that are commercially available or developmental products. These compounds are made from hydrazine, MMH, and UDMH and are for the most part heterocycHc nitrogen compounds (see Insect control technology). [Pg.289]

Hardness of the aimealed metals covers a wide range. Rhodium (up to 40%), iridium (up to 30%), and mthenium (up to 10%) are often used to harden platinum and palladium whose intrinsic hardness and tensile strength are too low for many intended appHcations. Many of the properties of rhodium and indium. Group 9 metals, are intermediate between those of Group 8 and Group 10. The mechanical and many other properties of the PGMs depend on the physical form, history, and purity of a particular metal sample. For example, electrodeposited platinum is much harder than wrought metal. [Pg.163]

The objective ia any analytical procedure is to determine the composition of the sample (speciation) and the amounts of different species present (quantification). Spectroscopic techniques can both identify and quantify ia a single measurement. A wide range of compounds can be detected with high specificity, even ia multicomponent mixtures. Many spectroscopic methods are noninvasive, involving no sample collection, pretreatment, or contamination (see Nondestructive evaluation). Because only optical access to the sample is needed, instmments can be remotely situated for environmental and process monitoring (see Analytical METHODS Process control). Spectroscopy provides rapid real-time results, and is easily adaptable to continuous long-term monitoring. Spectra also carry information on sample conditions such as temperature and pressure. [Pg.310]

The data available are generally for the Athabasca materials, although workers at the University of Utah (Salt Lake City) have carried out an intensive program to determine the processibiUty of Utah bitumen and considerable data have become available. Bulk properties of samples from several locations (Table 3) (9) show that there is a wide range of properties. Substantial differences exist between the tar sands in Canada and those in the United States a difference often cited is that the former is water-wet and the latter, oil-wet (10). [Pg.355]


See other pages where Wide range samples is mentioned: [Pg.58]    [Pg.313]    [Pg.257]    [Pg.58]    [Pg.367]    [Pg.65]    [Pg.58]    [Pg.313]    [Pg.257]    [Pg.58]    [Pg.367]    [Pg.65]    [Pg.1439]    [Pg.1561]    [Pg.1779]    [Pg.1941]    [Pg.2265]    [Pg.2956]    [Pg.116]    [Pg.99]    [Pg.222]    [Pg.93]    [Pg.332]    [Pg.770]    [Pg.105]    [Pg.108]    [Pg.83]    [Pg.201]    [Pg.407]    [Pg.279]    [Pg.396]    [Pg.188]    [Pg.305]    [Pg.60]    [Pg.310]    [Pg.333]    [Pg.393]    [Pg.393]   