Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Trace metals mass spectrometry

Table 1. Lead contamination blanks for serum collection, processing, and analysis by isotope dilution thermal ionization mass spectrometry in the WIGS Trace Metal/Mass Spectrometry facihty. University of California, Santa Cruz. Lead values are based upon repeated measurements. Table 1. Lead contamination blanks for serum collection, processing, and analysis by isotope dilution thermal ionization mass spectrometry in the WIGS Trace Metal/Mass Spectrometry facihty. University of California, Santa Cruz. Lead values are based upon repeated measurements.
To measure trace metals to the levels required in the guidelines involves the use of state-of-the-art instmmentation such as inductively coupled plasma/mass spectrometry (icp/ms). [Pg.447]

The conventional method for quantitative analysis of galHum in aqueous media is atomic absorption spectroscopy (qv). High purity metallic galHum is characteri2ed by trace impurity analysis using spark source (15) or glow discharge mass spectrometry (qv) (16). [Pg.160]

Mass spectrometry can be specific in certain cases, and would even allow on-line QA in the isotope dilution mode. MS of molecular ions is seldom used in speciation analysis. API-MS allows compound-specific information to be obtained. APCI-MS offers the unique possibility of having an element- and compound-specific detector. A drawback is the limited sensitivity of APCI-MS in the element-specific detection mode. This can be overcome by use of on-line sample enrichment, e.g. SPE-HPLC-MS. The capabilities of ESI-MS for metal speciation have been critically assessed [546], Use of ESI-MS in metal speciation is growing. Houk [547] has emphasised that neither ICP-MS (elemental information) nor ESI-MS (molecular information) alone are adequate for identification of unknown elemental species at trace levels in complex mixtures. Consequently, a plea was made for simultaneous use of these two types of ion source on the same liquid chromatographic effluent. [Pg.676]

Nearly every area of measurement science can boast of progress in measuring ever-smaller quantities of chemicals, but several stand out in their stunning trace-analysis capabilities. Trace-metal analysis has come to be dominated by methods that volatilize the sample and then either measure its spectroscopic emission or absorption, or measure the masses of the gaseous metal ions using mass spectrometry. Volatilization is accomplished by various thermal means that include flames, furnaces, and inductively coupled or microwave plasmas. The com-... [Pg.63]

Measurement techniques that can be employed for the determination of trace metals include atomic absorption spectrometry, anodic stripping voltammetry, differential pulse cathodic stripping voltammetry, inductively coupled plasma atomic emission spectrometry, liquid chromatography of the metal chelates with ultraviolet-visible absorption and, more recently, inductively coupled plasma mass spectrometry. [Pg.128]

In the analysis of seawater, isotope dilution mass spectrometry offers a more accurate and precise determination than is potentially available with other conventional techniques such as flameless AAS or ASV. Instead of using external standards measured in separate experiments, an internal standard, which is an isotopically enriched form of the same element, is added to the sample. Hence, only a ratio of the spike to the common element need be measured. The quantitative recovery necessary for the flameless atomic absorption and ASV techniques is not critical to the isotope dilution approach. This factor can become quite variable in the extraction of trace metals from the salt-laden matrix of seawater. Yield may be isotopically determined by the same experiment or by the addition of a second isotopic spike after the extraction has been completed. [Pg.286]

A logical approach which serves to minimise such uncertainties is the use of a number of distinctly different analytical methods for the determination of each analyte wherein none of the methods would be expected to suffer identical interferences. In this manner, any correspondence observed between the results of different methods implies that a reliable estimate of the true value for the analyte concentration in the sample has been obtained. To this end Sturgeon et al. [21] carried out the analysis of coastal seawater for the above elements using isotope dilution spark source mass spectrometry. GFA-AS, and ICP-ES following trace metal separation-preconcentration (using ion exchange and chelation-solvent extraction), and direct analysis by GFA-AS. These workers discuss analytical advantages inherent in such an approach. [Pg.335]

Lazof DB, Goldsmith JKG, Rufty TW, Suggs C, Linton RW. The preparation of cryosections from plant tissue an alternative method appropriate for secondary ion mass spectrometry studies of nutrient tracers and trace metals. JMicrosc 1994 176 99-109. [Pg.290]

The analysis of tetramethylammonium hydroxide (TMAH) solutions manufactured by SACHEM Inc. of Cleburne, Texas, includes the determination of trace elements. These elements cause less-than-optimum performance of integrated circuit boards manufactured by SACHEM s customers that use these solutions in their processes. Alkali and alkaline earth metals (e.g., Li, Na, K, Mg, Ca, and Ba) can reduce the oxide breakdown voltage of the devices. In addition, transition and heavy metal elements (e.g., Ti, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ag, Au, and Pb) can produce higher dark current. Doping elements (e.g., B, Al, Si, P, As, and Sn) can alter the operating characteristics of the devices. In SACHEM s quality control laboratory, ICP coupled to mass spectrometry is used to simultaneously analyze multiple trace elements in one sample in just 1 to 4 min. This ICP-MS instrument is a state-of-the-art instrument that can provide high throughput and low detection Emits at the parts per thousand level. Trace elemental determination at the parts per thousand level must be performed in a clean room so that trace elemental contamination from airborne particles can be minimized. [Pg.292]

The primary and immediate need is for a trace metal reference material, but a certified reference material would provide even greater benefits. A technique based on isotope dilution with detection by inductively-coupled plasma mass spectrometry (ICP-MS) (Wu and Boyle, 1998) most clearly meets the traceability criteria required for a certified reference material. Although useful for iron and several other metals, isotope dilution is not possible for monoisotopic elements like cobalt, so other techniques must also be used. Indeed, it is advisable that several techniques be used to certify a trace metal reference material. [Pg.49]

Cadmium in acidified aqueous solution may be analyzed at trace levels by various instrumental techniques such as flame and furnace atomic absorption, and ICP emission spectrophotometry. Cadmium in solid matrices is extracted into aqueous phase by digestion with nitric acid prior to analysis. A much lower detection level may be obtained by ICP-mass spectrometry. Other instrumental techniques to analyze this metal include neutron activation analysis and anodic stripping voltammetry. Cadmium also may be measured in aqueous matrices by colorimetry. Cadmium ions react with dithizone to form a pink-red color that can be extracted with chloroform. The absorbance of the solution is measured by a spectrophotometer and the concentration is determined from a standard calibration curve (APHA, AWWA and WEF. 1999. Standard Methods for the Examination of Water and Wastewater, 20th ed. Washington, DC American Public Health Association). The metal in the solid phase may be determined nondestructively by x-ray fluorescence or diffraction techniques. [Pg.143]

Iron metal can be analyzed by x-ray spectroscopy, flame- and furnace atomic absorption, and ICP atomic emission spectroscopy at trace concentration levels. Other instrumental techniques include ICP-mass spectrometry for extreme low detection level and neutron activation analysis. [Pg.414]

Molybdenum may be identified at trace concentrations by flame atomic absorption spectrometry using nitrous oxide-acetylene flame. The metal is digested with nitric acid, diluted and analyzed. Aqueous solution of its compounds alternatively may be chelated with 8—hydroxyquinobne, extracted with methyl isobutyl ketone, and analyzed as above. The metal in solution may also be analyzed by ICP/AES at wavelengths 202.03 or 203.84 nm. Other instrumental techniques to measure molybdenum at trace concentrations include x-ray fluorescence, x-ray diffraction, neutron activation, and ICP-mass spectrometry, this last being most sensitive. [Pg.584]

Internal standards are also used in trace metal analysis by inductively coupled plasma atomic emission spectrometry (ICP-AES) and inductively coupled plasma mass spectrometry (ICP-MS) techniques. An internal standard solution is added to ICP-MS and ICP-AES samples to correct for matrix effects, and the response to the internal standard serves as a correction factor for all other analytes (see also chapter 2). [Pg.133]

A semi-quantitative multi-element analysis - limited in accuracy and precision - is performed in solid-state mass spectrometry if the concentration of at least one element - used as an internal standard element - is known. For example, if trace impurities have to be analyzed in high purity copper metal, then Cu with a known concentration of 100% is chosen as the internal... [Pg.188]


See other pages where Trace metals mass spectrometry is mentioned: [Pg.395]    [Pg.85]    [Pg.416]    [Pg.230]    [Pg.113]    [Pg.527]    [Pg.648]    [Pg.651]    [Pg.55]    [Pg.64]    [Pg.141]    [Pg.259]    [Pg.286]    [Pg.125]    [Pg.135]    [Pg.306]    [Pg.8]    [Pg.6]    [Pg.99]    [Pg.539]    [Pg.46]    [Pg.20]    [Pg.621]    [Pg.18]    [Pg.6]    [Pg.16]    [Pg.67]    [Pg.178]    [Pg.188]    [Pg.209]    [Pg.255]    [Pg.256]    [Pg.260]   