Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Standardized tools

The drawing software comprises a comprehensive collection of standard tools to sketch 2D chemical structures. To specify all its facilities and tools would go far beyond the scope of this overview, but there are some nice features that are very useful for chemists so they are mentioned here briefly. One of these enables the prediction of H and NMR shifts from structures and the correlation of atoms with NMR peaks (Figure 2-127). lUPAC standard names can be generated... [Pg.139]

Common Tools. Specialty tooling for maintenance repairs should be avoided. Standard tools readily available to the maintenance organization should be used. [Pg.5]

LEED is the most powerfiil, most widely used, and most developed technique for the investigation of periodic surface structures. It is a standard tool in the surface analysis of single-crystal surfaces. It is used very commonly as a method to check surface order. The evolution of the technique is toward greater use to investigate surface disorder. Progress in atomic-structure determination is focused on improving calculations for complex molecular surface structures. [Pg.262]

Since then, TXRE has become the standard tool for surface and subsurface microanalysis [4.7-4.11]. In 1983 Becker reported the angular dependence of X-ray fluorescence intensities in the range of total reflection [4.12]. Recent demands have set the pace of further development in the field of TXRE - improved detection limits [4.13] in combination with subtle surface preparation techniques [4.14, 4.15], analyte concentrations extended even to ultratraces (pg) of light elements, e. g. A1 [4.16], spe-dation of different chemical states [4.17], and novel optical arrangements [4.18] and X-ray sources [4.19, 4.20]. [Pg.181]

The heart of any drill pipe string is the threaded rotary shoulder connection (Figure 4-133), known as the tool joint. Today, the only API standard tool Joint is the weld-on Joint shown at the bottom of Figure 4-133. [Pg.748]

When the circulation is started, the poppet valve travels slowly down, generating one pressure pulse when passing each restriction. The measurement range in the standard tool is of 2.5° (also 7° ranges, 1° increments, max. 17°). [Pg.929]

Whole article tests Grain tests are open to the criticism that they do not necessarily reflect the behaviour of the finished product in service, hence various tests on complete glass articles have been developed. These are normally carried out under accelerated conditions, and on completion various relevant factors are determined, such as loss in weight, alkali or other constituents extracted, the weight of soluble and insoluble materials in the extract and an assessment of surface condition. The advent of the electron microscope as a standard tool has made the latter study much more objective. [Pg.876]

Our results demonstrate well the complexities of polyelectrolyte adsorption and provide a basis for various surface treatments utilizing polyelectrolytes. They especially afford physical-chemical support for alternate layer-by-layer film formation of polyelectrolytes, which is becoming a standard tool for building composite polymer nano-films in advanced materials science. [Pg.9]

However, adoption of ELNs as a standard tool within corporate research was hampered by both the legal and regulatory requirements of the time. The FDA, the federal courts, and the USPTO were not really aligned to adoption of electronic records for NDA submission or for patent purposes. This was to... [Pg.211]

It is therefore easy to see why this current drug safety paradigm, with its lack of standards in data collection and analysis, hinders the analysis of adverse events. Without data standards in place, it is difficult to build practical, reusable tools for systematic safety analysis. With no standard tools, truly standardized analyses cannot occur. Reviewers may forget their initial analytical processes if they are not using standardized data and tools. Comprehensive reproducibility and auditability, therefore, become nearly impossible. In practice, the same data sets and analytical processes cannot be easily reused, even by the same reviewers who produced the original data sets and analyses. Not using standardized tools slows the real-time systematic analysis... [Pg.652]

Transition-metal chemistry in particular was the field where pioneering density functional results have been of unprecedented accuracy for larger systems and impressive to any researcher in the field. Today, it seems that density functional theory has adopted the role of a standard tool for the prediction of molecular structures. [Pg.135]

Linssen and de Vries [285] have examined 1 % di-f-butyl-p-cresol (DBPC) in low-MW poly(tetrahydro-furan) by means of DOSY (Figure 5.13). DOSY is a powerful tool for the analysis of polydisperse samples and complex mixtures, such as anionic surfactants. It is not to be expected that DOSY will rapidly become a standard tool in polymer/additive analysis. [Pg.340]

Some of the most memorable scenes in a motion picture are the creation of special effects technicians. One standard tool in the entertainment industry to create ambience, simulate specific designs such as volcanoes or swamps, or accentuate optical effects is fog production. (In the theatrical sense, the terms fog and smoke are used interchangeably for mist consisting entirely of liquid droplets. In the chemical sense, fog refers to a liquid phase dispersed in a gas, while smoke contains solid particulate matter dispersed in a gas.) There are a variety of approaches to creating artificial fog or smoke. [Pg.23]

In summary, the Gibbs ensemble MC methodology provides a direct and efficient route to the phase coexistence properties of fluids, for calculations of moderate accuracy. The method has become a standard tool for the simulation community, as evidenced by the large number of applications using the method. Histogram reweighting techniques (Chap. 3) have the potential for higher accuracy, especially if... [Pg.359]

Computational fluid dynamics (CFD) is rapidly becoming a standard tool for the analysis of chemically reacting flows. For single-phase reactors, such as stirred tanks and empty tubes, it is already well-established. For multiphase reactors such as fixed beds, bubble columns, trickle beds and fluidized beds, its use is relatively new, and methods are still under development. The aim of this chapter is to present the application of CFD to the simulation of three-dimensional interstitial flow in packed tubes, with and without catalytic reaction. Although the use of... [Pg.307]

Complicating matters further is the fact that the platinum electrode, the standard tool for measuring Eh directly, does not respond to some of the most important redox couples in geochemical systems. The electrode, for example, responds incorrectly or not at all to the couples SO -HS-, O2-H2O, CO2-CH4, NOJ-N2, and N2-NH4 (Stumm and Morgan, 1996 Hostettler, 1984). In a laboratory experiment, Runnells and Lindberg (1990) prepared solutions with differing ratios of selenium in the Se4+ and Se6+ oxidation states. They found that even under controlled conditions the platinum electrode was completely insensitive to the selenium composition. The meaning of an Eh measurement from a natural water, therefore, may be difficult or impossible to determine (e.g., Westall, 2002). [Pg.103]

Since the discovery, in the early 1990s that polymers can be ionized by matrix-assisted laser desorption/ionization (MALDI see Section 2.1.22) in a fashion similar to proteins, MALDI is rapidly becoming a standard tool in polymer characterization [4-6]. [Pg.299]

It follows from the above facts that fluids can be treated as continuous media with continuous distributions of properties such as the pressure, density, temperature and velocity. Not only does this imply that it is unnecessary to consider the molecular nature of the fluid but also that meaning can be attached to spatial derivatives, such as the pressure gradient dP/dx, allowing the standard tools of mathematical analysis to be used in solving fluid flow problems. [Pg.2]

Raman scattering are generally different so information from Raman experiments in general supplements information that is obtainable from infrared absorption. Using lasers as light sources can greatly reduce experimental difficulties in this technique. At present it has become one of the standard tools for polymer analysis. [Pg.78]

If quantum theory is to be used as a chemical tool, on the same kind of basis as, say, n.m.r. or mass spectrometry, one must be able to carry out calculations of high accuracy for quite complex molecules without excessive cost in computation time. Until recently such a goal would have seemed quite unattainable and numerous calculations of dubious value have been published on the basis that nothing better was possible. Our work has shown that this view is too pessimistic semiempirical SCF MO treatments, if properly applied, can already give results of sufficient accuracy to be of chemical value and the possibilities of further improvement seem unlimited. There can therefore be little doubt that we are on the threshold of an era where quantum chemistry will serve as a standard tool in studying the reactions and other properties of molecules, thus bringing nearer the fruition of Dirac s classic statement, that with the development of quantum theory chemistry has become an exercise in applied mathematics. [Pg.28]


See other pages where Standardized tools is mentioned: [Pg.805]    [Pg.124]    [Pg.219]    [Pg.11]    [Pg.210]    [Pg.105]    [Pg.83]    [Pg.75]    [Pg.4]    [Pg.671]    [Pg.226]    [Pg.123]    [Pg.98]    [Pg.152]    [Pg.212]    [Pg.253]    [Pg.66]    [Pg.34]    [Pg.5]    [Pg.28]    [Pg.332]    [Pg.393]    [Pg.393]    [Pg.430]    [Pg.310]    [Pg.126]    [Pg.289]    [Pg.173]    [Pg.36]    [Pg.121]   
See also in sourсe #XX -- [ Pg.652 ]




SEARCH



Machine Tool Safety Standards Committee

Standard work tools

Standardized tools/techniques

Tablet tooling standard

Tablet tooling standardization

Tablet tooling standardized

Tools standardize

Tools standardize

Tools standards

Tools standards

© 2024 chempedia.info