In filled thermometers the thermal expansion of a gas or a liquid is transmitted through a thin capillary tube to a bellows or helix, where the deformation indicates the temperature. The temperature range of filled thermometers is very wide, approximately -200 to +700 °C. They are extremely robust but are not very high in accuracy. The application is mainly for process instrumentation and as stand-alone control devices. [Pg.1137]

A setting knob is provided on the more traditional stand-alone controllers for the adjustment of Kc as well as a pointer to set the desired value. The setting knob for Kc is sometimes graduated in terms of proportional band. This quantity is defined as the error required to move the final control element over its whole range and is expressed as a percentage of the total range of the measured variable (see Example 7.1). In the newer MBC installations, the control action is simulated in the form of software and values of Kc and of the desired value are entered via an appropriate keyboard with the relevant values displayed on a VDU (Visual Display Unit)—see Section 7.19. [Pg.567]

The maximum deviation etc. of the controlled variable is determined by the settings of both Kc and r, which can be keyed into an MBC system as required. A second knob is provided on a stand-alone controller and is calibrated either in terms of r, min or 1/T>(min)-1. The latter is called the reset rate. [Pg.569]

Automatic control systems can be based on individual stand-alone controllers or computer based systems. Individual controllers are easier to specify, readily available, and require less design and little or no programming. However, system integration is very difficult and data gathering remains a separate problem. System installation and maintenance are expensive and overall system... [Pg.2157]

A perfect workable control structure for a stand-alone unit can become unfeasible because of interactions with other units by recycles. The opposite might also be true an infeasible stand-alone control structure can become feasible when the interactions along... [Pg.509]

The conhol system has the task of coordinating the machine movement sequences. It is usually housed in a stand alone control cabinet alongside the machine... [Pg.140]

The system can be operated from stand-alone control via an LCD and a membrane keypad screen on the instrument. Seven pre-programmed protocols are provided and a maximum of 36 sequences containing 101 amino acids in length in each of the eight user profiles is allowed. Alternatively, for more flexibility, full protocol editing, chemical editing, and database capability, the system can be controlled from a computer workstation with icon-driven easy-to-use Windows 95-based software. [Pg.291]

Where a simple stand-alone controller performs the control function it is easy to consider that the controller may fail in a limited set of modes, e.g. output to a valve could go high, low or frozen or even oscillating. [Pg.104]

Now that we have covered how the controller works it is necessary to discuss controller hardware. Figures 4.19 and 4.20 are examples of single-loop stand alone controllers. Figure 4.19 is an electronic analog controller from the 1970s. [Pg.113]

Stand-alone computer systems, usually based on a personal computer (PC) or programmable logic controller (PLC), provide a separate computer system for each pilot plant. This allows for economical expansion for new units, separates pilot plants completely for maintenance and troubleshooting, and often has the lowest initial cost. Standardization can be a problem and software control, data gathering, and storage packages can be limited in size, scope, and capabiUty these are usually acceptable trade-offs. [Pg.42]

The maintenance of analytical instmmentation requkes trained personnel and is a time-consuming task (39,40). An additional problem is the necessity of frequentiy checking the caUbration of the analysis instmmentation and recahbrating if requked. Stand-alone data gathering instmmentation, once common in pilot plants, has been vktuaHy replaced in all but the simplest pilot plants by a data gathering computer, usually used for process control as well. [Pg.42]

An important feature of the typical system is its modularity. The most powerful EMCS installations have all three components, but often only a single module is necessai y for simple applications, such as controlling a single air-conditioning unit, or for most applications in the residential sector. Thus local and control modules arc capable of stand-alone operation without higher-level components. The functions,... [Pg.465]

Here is a typical example of a stand-alone cleaner that temporarily supplants the existing deposit control product. The program still demands the use of an oxygen scavenger and condensate line treatment. [Pg.629]

Cyclone separators Often used as roughing systems in process industries before other forms of emission control equipment, seldom satisfactory as stand-alone equipment. [Pg.678]

When the first of our new pilot plants was designed we had the option of full computer control. We decided to Install stand-alone solid state controllers and safety systems to allow the fullest operating flexibility and the best possible data retrieval. The computers chosen for the latter have the capability when we wish to control temperature, pressure or feeds using our own algorithms. [Pg.455]

Semiautomatic devices suited for preparative purposes are the CAMAG Linomat 5, the Desaga HPTLC applicator AS 30, and the Alltech TLC sample streaker. For all devices, the syringe has to be filled manually with sample solution and rinsed after sample application. Except for the Alltech TLC sample streaker, each of these instruments can be employed either as software-controlled or as a stand-alone device. The former is more convenient for creation, editing, and saving of the application pattern and instrument parameters. [Pg.107]

Figure 5-1 illustrates a method that will produce a system in which the parts fit together to accomplish the common goal of good control. Control valve share of total system flowing pressure drop will be 60% at normal flow. The system will still achieve maximum flow as long as the control valve trim selected can pass maximum flow at operating head loss (line 23 of Figure 5-1). The procedure described in Figure 5-1 is intended as a stand-alone device for guiding the calculations, and worksheets can be prepared from it. Figure 5-1 illustrates a method that will produce a system in which the parts fit together to accomplish the common goal of good control. Control valve share of total system flowing pressure drop will be 60% at normal flow. The system will still achieve maximum flow as long as the control valve trim selected can pass maximum flow at operating head loss (line 23 of Figure 5-1). The procedure described in Figure 5-1 is intended as a stand-alone device for guiding the calculations, and worksheets can be prepared from it.
A Phase II study was recently completed whereby Org-25935 was compared against placebo for the ability to improve negative symptoms in 246 subjects maintained on a stable dose of an atypical antipsychotic (data not disclosed) [46]. A second Phase II study in progress (200 patients) is designed to assess the efficacy of Org-25935 as a stand-alone therapy versus placebo, using olanzapine as the active control [46]. Org-25935 is also being investigated in separate Phase II studies as a treatment for panic disorder and for recidivism in subjects with alcohol dependence [46]. [Pg.24]

For energy security reasons, the presence of an auxiliary power supply unit is necessary. This unit can be preferably either a hydrogen internal combustion engine (H2 ICE) or a fuel cell of corresponding capacity to meet at least the minimum needs of the system. In this case, the system is an autonomous power plant. Figure 5.11 shows a stand-alone wind-hydrogen system that is autonomous. The dashed line in some parts of it implies that these connections may not exist as well. The DC/AC converter/controller should have the capability to operate vice versa and power up the lines through the power controller. [Pg.175]

Throughout the book I have tried to constrain the wonders of imagination inspired by the subject by using simple calculations. Can all of the water on the Earth have been delivered by comets if so, how many comets How do I use molecular spectroscopy to work out what is happening in a giant molecular cloud Calculations form part of the big hard-sell for astrochemistry and they provide a powerful control against myth. I have aimed the book at second-year undergraduates who have had some exposure to quantum mechanics, kinetics, thermodynamics and mathematics but the book could easily be adapted as an introduction to all of these areas for a minor course in chemistry to stand alone. [Pg.360]

Stand alone fire or gas detection and alarm panels are normally provided in the main control facility for the installation. Recent trends also incorporate the transmittal of fire and gas alarms through the DCS into the main process alarm real time control panel. When alarm panels are located within a protected building, they should be located for easy access for emergency response personnel and proximity to manual electrical power shut off facilities. [Pg.190]

The LC control software, either stand-alone or as part of an overall data-handling system, should be tested by means of a separate OQ protocol. This protocol only needs to address the communica-tions/control integrity of the hardware (e.g., setting up a run/sequence with the proper instrument parameters, the ability to start and stop the pump, etc.). It should cover all the required instrument control functions listed as part of the protocol s functional specifications. It does not need to include specific hardware performance testing, such as linearity or flow rate. The latter tests are performed separately, as part of the individual hardware validation described below. [Pg.310]


See other pages where Stand-alone controller is mentioned: [Pg.321]    [Pg.283]    [Pg.321]    [Pg.283]    [Pg.156]    [Pg.42]    [Pg.61]    [Pg.33]    [Pg.399]    [Pg.363]    [Pg.504]    [Pg.156]    [Pg.124]    [Pg.30]    [Pg.42]    [Pg.608]    [Pg.29]    [Pg.62]    [Pg.42]    [Pg.323]    [Pg.141]    [Pg.262]    [Pg.169]    [Pg.170]    [Pg.178]    [Pg.287]    [Pg.220]    [Pg.449]    [Pg.158]    [Pg.222]   