Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Setting times adjustment

P 19] Two micro syringes were filled with 0.32 mM p-nitrophenyl-y9-D-galacto-pyranoside in phosphate buffer (pH 8) and /3-galactosidase (20 U) in 10 ml of the same buffer [26]. Both solutions were pumped into the micro channel at the same flow rate (a few pi min ). The reaction was carried out for 0-30 min at 37 °C using a hot-plate. The residence time was set by adjusting the flow rate. After passing the micro channel, the reaction mixture was dropped into hot water to inactivate the enzyme. [Pg.442]

Data adequacy The key study was well conducted and documented. Supporting data include both human and animal studies. Animal studies covered acute, subchronic, and chronic exposure durations and addressed systemic toxicity as well as neurotoxicity, reproductive and developmental effects, cardiac sensitization, genotoxicity, and carcinogenicity. Other effects in animal studies occurred at much higher concentrations or with repeated exposures the latter are not relevant for setting short-term exposures. No effects other than narcosis occurred in rats and mice exposed at 200,000 ppm for various periods of time. Adjustment by a total UF of 10 results in a higher value (20,000 ppm) than from the cardiac sensitization test with dogs. ... [Pg.180]

When added at dosage of 2% by weight of cement to a concrete mixture with 460 kg m of cement without adjustment for the volume of the water introduced by the admixture, the concrete s slump and porosity are increased. However, when substituted for an equal volume of water, the SRA has little or no effect on concrete slump. It does have a slight retarding effect on the rate of hydration and may extend the setting time up to about an hour. The admixture also affects the air content of fresh concrete and therefore when used in air-entrained concrete, the air-entraining admixture dosage must be increased to achieve a specified air content. [Pg.382]

Trial mixtures can be made with a range of cement contents or water- cement ratios or other properties to bracket the job requirements. The evaluation will permit adjustment of the manufacturer s recommended dosage required to meet the difference in air content and setting time produced in bulk mixes and also the dosage that may be necessary to enhance a particular secondary effect. It will also enable determination of the cost of using the admixture for the specific application. [Pg.517]

These fuzes, sometimes called "Posit" Buck Rogers" "Special" "Influence" and "Bonzo" are in effect "automatic time fuzes". Without "setting" or "adjustment" they detonate the missiles that carry them on approach to the target at the desired point on their trajectories, such as... [Pg.918]

Its function is to expand the pressurized solution to separate the "solvent gas" from dissolved extracted components. If a fixed restrictor is used, the mass flow rate of the fluid changes as a function of pressure (density) mass flow can increase by a factor of 25 as pressure is increased from 80 to 400 bar (24). Not only are the pressure and flow coupled, the coupling is via a static conduit whose dimensions are imprecisely controlled during an extraction (partial plugging by particulates and precipitated components, temperature) and from component to component during maintenance replacements. This results in a lack of control in operating parameters (density) and timed sequences (via flow rate and time). A variable restrictor whose dimensions are set and adjusted by an electronic feedback control loop is an alternative solution. [Pg.272]

Other tools you will need for HPLC are fairly standard for a lab with a few exceptions. I keep two of the small open wrenches supplied with an HPLC system or a column for use with compression fittings, 1/4-in, a 5/8-in box wrench, and a 6-in crescent wrench for column work, a file, a Terry tool tubing cutter, a couple of pairs of blunt nose pliers for tube flexing during cutting, a reversible screw driver, a jeweler s screwdriver for phoenix block s screws, a universal Allen wrench set, an adjustable-head dental mirror (for seeing behind boxes to hook up leads), and a stopwatch for timing flow. The key is to lock up your tool kit to prevent tool evaporation. [Pg.129]

At the same time, it seems reasonable to reduce considerably the set of adjustable parameters. Actually, certain relations exist between them, originating both from their physical nature and the method of their determination. So the overlap intergrals SAB, which alongside the VOIP of atom A affect essentially the main characteristics of the electron structure of a cluster, depend on nA, /A, A, and RAB. The arbitrariness in choosing these parameters is therefore obvious. Taking into account, in addition, the model nature of the very cluster scheme which is directed to make some qualitative conclusions, it seems inappropriate to attach too much importance to this maximal optimization. [Pg.141]

To account for this in the computer calculations, an oxidation step was incorporated into the SECTOR code as described earlier. The proportionality constant A of equation (3) was determined empirically to be that which gave the best fit for a number of experimentally determined profiles obtained under various conditions of acidity and heavy element concentration. When using HAN as reductant, a value of A = 1.5 L/mol per unit of setting time appears to be most appropriate. The calculated profile incorporating the oxidation step is also shown in Figure 5 as solid lines. Note that the shape of the experimental profile is reproduced extremely well, using only this single adjustable parameter in the pseudo kinetic expression for the Pu(III) oxidation. [Pg.347]

Computers continued to get smaller, faster, and cheaper. The accuracy and speed of chemical analysis continued to improve. With real-time chemical analysis of process streams and a mathematical model for each unit in the process, the computer was programmed to set controllers on process streams using the new process control algorithms. With some additional programming and with the process control set points adjusted by the computer control system, the quality of the product improved. The physical property data for the chemicals in the process streams required for these model calculations were built into the process control program. [Pg.815]

There are several methods, visual, quantitative, and semiquantitative, to determine the tumor uptake of FDG. Visual assessment is commonly used in tumor diagnosis and staging, and is based on differences in contrast between tumor and adjacent tissue. This is a simplified method requiring only a single static image at a set time after injection and can be equally applied to assess the therapeutic response of the tumor. In the visual technique, it is important to adjust the image intensities of the tumor and adjacent tissues to the same gray or color scale. [Pg.227]

The traditional limit is three times the noise level. Turn on the instrument, set every adjustment at the highest sensitivity, and record the signal with no sample present. The random fluctuation is the noise level. Three times this is taken as the minimum level of detection. [Pg.230]

Fluorescence spectra and UVA IS spectra of compound solutions were recorded freshly, after one day and two months against its solvents and then they were compared to each other. Optimum fluorescence measurement settings were adjusted as 2 = 337 nm, int time 0.1, step size 0.5, averages 3, slit with completely open and then they were compared to each other. [Pg.412]

The screw-crammer system uses a conical hopper with a screw that is driven by a separate gear reducer and variable-speed drive motor. The output and effectiveness of the crammer are determined by the screw configuration and the available speed. The ram-type system, on the other hand, uses a pneumatic ram to stuff material into the screw. The ram is a piston-driven unit with the stroke timing adjustable by setting a series of timers located in the control panel. The feed section used by the ram system has an opening that is 12-14 times larger than that of a standard screw extruder. This allows low-bulk-density material to flow freely into the feed throat where the ram can compress it into the screw. Depending on the extruder size, the ram can compact materials with a force of 2000-9000 psi. [Pg.731]

This longer setting time of slag cement can be turned to account in the ready mix concrete technology the concrete mixture should have delayed set adjusted to the transport period. [Pg.550]


See other pages where Setting times adjustment is mentioned: [Pg.289]    [Pg.289]    [Pg.1424]    [Pg.401]    [Pg.187]    [Pg.474]    [Pg.118]    [Pg.364]    [Pg.450]    [Pg.100]    [Pg.446]    [Pg.468]    [Pg.886]    [Pg.995]    [Pg.187]    [Pg.115]    [Pg.182]    [Pg.335]    [Pg.353]    [Pg.298]    [Pg.1972]    [Pg.429]    [Pg.257]    [Pg.236]    [Pg.157]    [Pg.4]    [Pg.1424]    [Pg.460]    [Pg.100]    [Pg.520]    [Pg.202]    [Pg.741]    [Pg.366]    [Pg.507]    [Pg.72]   
See also in sourсe #XX -- [ Pg.4 ]




SEARCH



Adjustment time

Setting time

© 2024 chempedia.info