Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Sensitization contaminants

Chemical analysis for specific redox couples is especially useful in studies of groundwaters contaminated by waste disposal, where redox gradients are often steep, and the fate of redox-sensitive contaminants may be rate dependent or otherwise unpredictable. In such a study of sewage-contaminated groundwaters, Kent et al. (1994) found that reduction of O2, Cr(VI), and Se(VI) did not occur, although it was thermodynamically favored. They concluded that the disequilbrium resulted from unfavorable microbial conditions and heterogeneity of groundwater flow. [Pg.415]

Contamination Problems. As analytical techniques become more sensitive, contamination becomes more of a problem. For example, Ochs (25) reported that many erroneous bands in polyacrylamide gels run with SDS were from proteins found on the skin of the researchers handling the gels. Her work indicates the need to exercise extreme care in sample preparation. In addition, suitable sample blanks handled in a parallel fashion would enable the researcher to identify contamination problems. Secondary checking of materials by two-dimensional electrophoresis would also help identify the nature and type of contamination. [Pg.106]

The lifetime of the quartz tube atomiser is variable and can range up to several months. New tubes initially perform poorly and must be conditioned by several runs before achieving optimum sensitivity. Contamination of the quartz surface may result in significant signal suppression. As the electrothermal quartz furnace atomiser is comparatively robust and offers high overall efficiency and sensitivity at relatively low cost, it has found widespread application for the analysis of organo-metallic species of the elements Sn, Se, As, Sb, Pb, and Hg. [Pg.468]

Benzophenones constitute another group of suntan preparations. Deoxyben-zone and/or oxybenzone caused allergic contact dermatitis in a few patients (Thompson et al. 1977 Parker 1977). A concomitant positive reaction to deoxy-benzone and oxybenzone was explained as cross-sensitization or concomitant sensitization contamination of one with the other was ruled out by chromatographic analysis in Pariser s case. Thompson et al. (1977) also mentioned a new suntan preparation sensitizer, cinoxate. [Pg.362]

Thermal sensitivity, contamination tendency, foaming properties, material properties... [Pg.217]

Heterogeneous catalysts are more common. However, they degrade and need replacement. If contaminants in the feed material or recycle shorten catalyst life, then extra separation to remove these contaminants before the feed enters the reactor might be justified. If the cataylst is sensitive to extreme conditions, such as high temperature, then some measures can help to avoid local hot spots and extend catalyst life ... [Pg.279]

Feedstocks come mainly from catalytic cracking. The catalyst system is sensitive to contaminants such as dienes and acetylenes or polar compounds such as water, oxygenates, basic nitrogen, organic sulfur, and chlorinated compounds, which usually require upstream treatment. [Pg.376]

Detection of cantilever displacement is another important issue in force microscope design. The first AFM instrument used an STM to monitor the movement of the cantilever—an extremely sensitive method. STM detection suffers from the disadvantage, however, that tip or cantilever contamination can affect the instrument s sensitivity, and that the topography of the cantilever may be incorporated into the data. The most coimnon methods in use today are optical, and are based either on the deflection of a laser beam [80], which has been bounced off the rear of the cantilever onto a position-sensitive detector (figme B 1.19.18), or on an interferometric principle [81]. [Pg.1693]

The most often used subphase is water. Mercury and otlier liquids [12], such as glycerol, have also occasionally been used [13,14]. The water has to be of ultrapure quality. The pH value of tire subphase has to be adjusted and must be controlled, as well as tire ion concentration. Different amphiphiles are differently sensitive to tliese parameters. In general it takes some time until tire whole system is in equilibrium and tire final values of pressure and otlier variables are reached. Organic contaminants cannot always be removed completely. Such contaminants, as well as ions, can have a hannful influence on tire film preparation. In general, all chemicals and materials used in tire film preparation have to be extremely pure and clean. [Pg.2611]

Standardizing the Method Equations 10.32 and 10.33 show that the intensity of fluorescent or phosphorescent emission is proportional to the concentration of the photoluminescent species, provided that the absorbance of radiation from the excitation source (A = ebC) is less than approximately 0.01. Quantitative methods are usually standardized using a set of external standards. Calibration curves are linear over as much as four to six orders of magnitude for fluorescence and two to four orders of magnitude for phosphorescence. Calibration curves become nonlinear for high concentrations of the photoluminescent species at which the intensity of emission is given by equation 10.31. Nonlinearity also may be observed at low concentrations due to the presence of fluorescent or phosphorescent contaminants. As discussed earlier, the quantum efficiency for emission is sensitive to temperature and sample matrix, both of which must be controlled if external standards are to be used. In addition, emission intensity depends on the molar absorptivity of the photoluminescent species, which is sensitive to the sample matrix. [Pg.431]

Eventually, multipliers become less sensitive and even fail because of surface contamination caused by the imperfect vacuum in the mass spectrometer and the impact of ions on the surfaces of the dynodes. [Pg.203]

Plutonium (Pu) is an artificial element of atomic number 94 that has its main radioactive isotopes at 2 °Pu and Pu. The major sources of this element arise from the manufacture and detonation of nuclear weapons and from nuclear reactors. The fallout from detonations and discharges of nuclear waste are the major sources of plutonium contamination of the environment, where it is trapped in soils and plant or animal life. Since the contamination levels are generally very low, a sensitive technique is needed to estimate its concentration. However, not only the total amount can be estimated. Measurement of the isotope ratio provides information about its likely... [Pg.369]

Chemical Gas Detection. Spectral identification of gases in industrial processing and atmospheric contamination is becoming an important tool for process control and monitoring of air quaUty. The present optical method uses the ftir (Fourier transform infrared) interference spectrometer having high resolution (<1 cm ) capabiUty and excellent sensitivity (few ppb) with the use of cooled MCT (mercury—cadmium—teUuride) (2) detectors. [Pg.295]

Process Concepts. Hybrid systems involving gas-phase adsorption coupled with catalytic processes and with other separations processes (especially distillation and membrane systems) will be developed to take advantage of the unique features of each. The roles of adsorption systems will be to efficiently achieve very high degrees of purification to lower fouUng contaminant concentrations to very low levels in front of membrane and other separations processes or to provide unique separations of azeotropes, close-boiling isomers, and temperature-sensitive or reactive compounds. [Pg.287]

Aqueous formaldehyde is corrosive to carbon steel, but formaldehyde in the vapor phase is not. AH parts of the manufacturing equipment exposed to hot formaldehyde solutions must be a corrosion-resistant alloy such as type-316 stainless steel. Theoretically, the reactor and upstream equipment can be carbon steel, but in practice alloys are required in this part of the plant to protect the sensitive silver catalyst from metal contamination. [Pg.494]

A second type of uv curing chemistry is used, employing cationic curing as opposed to free-radical polymerization. This technology uses vinyl ethers and epoxy resins for the oligomers, reactive resins, and monomers. The initiators form Lewis acids upon absorption of the uv energy and the acid causes cationic polymerization. Although this chemistry has improved adhesion and flexibility and offers lower viscosity compared to the typical acrylate system, the cationic chemistry is very sensitive to humidity conditions and amine contamination. Both chemistries are used commercially. [Pg.248]

Methods for iodine deterrnination in foods using colorimetry (95,96), ion-selective electrodes (94,97), micro acid digestion methods (98), and gas chromatography (99) suffer some limitations such as potential interferences, possibHity of contamination, and loss during analysis. More recendy neutron activation analysis, which is probably the most sensitive analytical technique for determining iodine, has also been used (100—102). [Pg.364]

Operation nd Control. Control of chromium chromate conversion coating baths is accompHshed by controlling chromium concentration and pH. The quaHty of the conversion coating is sensitive to aluminum accumulations in the coating bath as well as to rinse water purity. Sulfate contamination is a particular problem. [Pg.224]


See other pages where Sensitization contaminants is mentioned: [Pg.504]    [Pg.846]    [Pg.19]    [Pg.470]    [Pg.5027]    [Pg.735]    [Pg.481]    [Pg.112]    [Pg.504]    [Pg.846]    [Pg.19]    [Pg.470]    [Pg.5027]    [Pg.735]    [Pg.481]    [Pg.112]    [Pg.303]    [Pg.1800]    [Pg.1861]    [Pg.2745]    [Pg.552]    [Pg.228]    [Pg.190]    [Pg.24]    [Pg.45]    [Pg.131]    [Pg.142]    [Pg.231]    [Pg.502]    [Pg.12]    [Pg.40]    [Pg.180]    [Pg.514]    [Pg.577]    [Pg.526]    [Pg.391]    [Pg.107]    [Pg.229]    [Pg.356]    [Pg.356]    [Pg.276]   
See also in sourсe #XX -- [ Pg.81 ]




SEARCH



© 2024 chempedia.info