To calculate N (E-Eq), the non-torsional transitional modes have been treated as vibrations as well as rotations [26]. The fomier approach is invalid when the transitional mode s barrier for rotation is low, while the latter is inappropriate when the transitional mode is a vibration. Hamionic frequencies for the transitional modes may be obtained from a semi-empirical model [23] or by perfomiing an appropriate nomial mode analysis as a fiinction of the reaction path for the reaction s potential energy surface [26]. Semiclassical quantization may be used to detemiine anliamionic energy levels for die transitional modes [27]. [Pg.1016]

Population anaiysis methods of assigning charges rely on the LCAO approximation and express the numbers of electrons assigned to an atom as the sum of the populations of the AOs centered at its nucleus. The simplest of these methods is the Coulson analysis usually used in semi-empirical MO theory. This analysis assumes that the orbitals are orthogonal, which leads to the very simple expression for the electronic population of atom i that is given by Eq. (53), where Natomic orbitals centered... [Pg.391]

A variety of methods have been developed by mathematicians and computer scientists to address this task, which has become known as data mining (see Chapter 9, Section 9.8). Fayyad defined and described the term data mining as the nontrivial extraction of impHcit, previously unknown and potentially useful information from data, or the search for relationships and global patterns that exist in databases [16]. In order to extract information from huge quantities of data and to gain knowledge from this information, the analysis and exploration have to be performed by automatic or semi-automatic methods. Methods applicable for data analysis are presented in Chapter 9. [Pg.603]

First, considerably greater emphasis has been placed on semimicro techniques and their application to preparations, separations, analysis and physical determinations such as those of molecular weight. We have therefore greatly expanded the section on Manipulation on a semi-micro scale which was in the Third Edition, and we have described many more preparations on this scale, some independent and others as alternatives to the larger-scale preparations which immediately precede them. Some 40 separate preparations on the semi-micro scale are described in detail, in addition to specific directions for the preparation of many classes of crystalline derivatives required for identification purposes. The equipment required for these small-scale reactions has been selected on a realistic basis, and care has been taken not to include the very curious pieces of apparatus sometimes suggested as necessary for working on the semi-micro scale. [Pg.585]

For the more advanced student, we have extended the section on Quantitative Semi-micro Analysis, and we have included a section dealing with Special Techniques in Separation and Purification, namely Adsorption Chromatography, Paper Chromatography, and Ion- Exchange Processes. [Pg.586]

We have also added an entirely new section dealing with semi-microanalysis. In our original Introduction (p. ix) we justified the retention of macro-methods of quantitative analysis on the grounds that they formed an excellent introduction to micromethods and also afforded a valuable training in exact manipulation generally. By now, however, the macro-estimation particularly of carbon and hydrogen and of nitrogen has disappeared entirely from most laboratories. On the other hand, the micro-... [Pg.588]

In Laser Ionization Mass Spectrometry (LIMS, also LAMMA, LAMMS, and LIMA), a vacuum-compatible solid sample is irradiated with short pulses ("10 ns) of ultraviolet laser light. The laser pulse vaporizes a microvolume of material, and a fraction of the vaporized species are ionized and accelerated into a time-of-flight mass spectrometer which measures the signal intensity of the mass-separated ions. The instrument acquires a complete mass spectrum, typically covering the range 0— 250 atomic mass units (amu), with each laser pulse. A survey analysis of the material is performed in this way. The relative intensities of the signals can be converted to concentrations with the use of appropriate standards, and quantitative or semi-quantitative analyses are possible with the use of such standards. [Pg.44]

Fracture mechanics analysis requires the determination of the mode I stress intensity factor for a surface crack having a circular section profile. Here the circular section flaw will be approximated by a semi-elliptical flaw. [Pg.509]

A bulk sample is the last choice and the least desirable. It should be submitted "for laboratory use only" if there is a possibility of contamination by other matter. The type of bulk sample submitted to the laboratory should be cross-referenced to the appropriate air samples. A reported bulk sample analysis for quartz (or cristobalite) will be semi-quantitative in nature because (1) The XRD analysis procedure requires a thin layer deposition for an accurate analysis. (2) The error for bulk samples analyzed by XRD is unknown because the particle size of nonrespirable bulk samples varies from sample to sample. [Pg.253]

Semi quantitive speetrographie analysis of other elements 2ppm... [Pg.111]

Knowledge of these types of reaetors is important beeause some industrial reaetors approaeh the idealized types or may be simulated by a number of ideal reaetors. In this ehapter, we will review the above reaetors and their applieations in the ehemieal proeess industries. Additionally, multiphase reaetors sueh as the fixed and fluidized beds are reviewed. In Chapter 5, the numerieal method of analysis will be used to model the eoneentration-time profiles of various reaetions in a bateh reaetor, and provide sizing of the bateh, semi-bateh, eontinuous flow stirred tank, and plug flow reaetors for both isothermal and adiabatie eonditions. [Pg.220]

The engineer is offered a large variety of flow-modeling methods, whose complexity ranges from simple order-of-magnitude analysis to direct numerical simulation. Up to now, the methods of choice have ordinarily been experimental and semi-theoretical, such as cold flow simulations and tracer studies. [Pg.812]

In the simplified a/s analysis of Section 4.2 we assumed identical and constant specific heats for the two streams. Now we assume semi-perfect gases with specific heats as functions of temperature but we must also allow for the difference in gas properties between the cooling air and the mainstream gas (combustion products). Between entry states (mainstream gas 3g, and cooling air, 2c) and exit state 5m (mixed out), the steady flow energy equation, for the flow through control surfaces (A + B) and C, yields, for a stationary blade row,... [Pg.61]

Corti. G. and Manfrida G. (1998), Analysis of a semi-closed gas lurbine/combined cycle (SCGT/CC) with CO2 removal by amines absorption. International Conference On Greenhouse Gas Control Technologies, Interlaken. [Pg.164]

One can easily extend the above analysis to dilute and semi-dilute solutions of EP [65,66] if one recalls [67] from ordinary polymers that the correlation length for a chain of length / in the dilute limit is given by the size R of the chain oc When chains become so long that they start to overlap at I I (X the correlation length of the chain decreases and reflects... [Pg.521]

It was concluded from the analysis that blowdown response time was affected more by the attitude of the platform personnel toward the system than the reaction times of the system components. Therefore the implementation of semi or fully automatic blowdown on the platforms would not necessarily enhance performance unless the workers had support in terms of philosophy, training, procedures, and hardware reliability. [Pg.342]

Population analysis with semi-empirical methods requires a special comment. These methods normally employ the ZDO approximation, i.e. the overlap S is a unit matrix. The population analysis can therefore be performed directly on the density matrix. In some cases, however, a Mulliken population analysis is performed with DS, which requires an explicit calculation of the S matrix. [Pg.220]

Decreased total analysis time Requkes automated or semi-automated... [Pg.111]

Figure 15.11 (a) Total ion clnomatogram of a Grob test mixture obtained on an Rtx-1701 column, and (b) re-injection of the entire clnomatogram on to an Rtx-5 column. Peak identification is as follows a, 2,3-butanediol b, decane c, undecane d, 1-octanol e, nonanal f, 2,6-dimethylphenol g, 2-ethylhexanoic acid h, 2,6-dimethylaniline i, decanoic acid methyl ester ], dicyclohexylamine k, undecanoic acid, methyl ester 1, dodecanoic acid, methyl ester. Adapted from Journal of High Resolution Chromatography, 21, M. J. Tomlinson and C. L. Wilkins, Evaluation of a semi-automated multidimensional gas chromatography-infrared-mass specti ometry system for initant analysis , pp. 347-354, 1998, with permission from Wiley-VCH. [Pg.424]

M. J. Tomlinson and C. L. Wilkins, Evaluation of a semi-automated multidimensional gas chromatography-infared-mass spectrometry system for initant analysis , ]. High Resolut. Chromatogr. 21 347-354 (1998). [Pg.431]

In addition to the obvious structural information, vibrational spectra can also be obtained from both semi-empirical and ab initio calculations. Computer-generated IR and Raman spectra from ab initio calculations have already proved useful in the analysis of chloroaluminate ionic liquids [19]. Other useful information derived from quantum mechanical calculations include and chemical shifts, quadru-pole coupling constants, thermochemical properties, electron densities, bond energies, ionization potentials and electron affinities. As semiempirical and ab initio methods are improved over time, it is likely that investigators will come to consider theoretical calculations to be a routine procedure. [Pg.156]

No exact mathematical analysis of the conditions within a turbulent fluid has yet been developed, though a number of semi-theoretical expressions for the shear stress at the walls of a pipe of circular cross-section have been suggested, including that proposed by BLAS1US.(6)... [Pg.83]


See other pages where Semi analysis is mentioned: [Pg.391]    [Pg.11]    [Pg.702]    [Pg.589]    [Pg.346]    [Pg.771]    [Pg.815]    [Pg.76]    [Pg.24]    [Pg.280]    [Pg.564]    [Pg.178]    [Pg.315]    [Pg.811]    [Pg.44]    [Pg.534]    [Pg.310]    [Pg.88]    [Pg.179]    [Pg.427]    [Pg.387]    [Pg.44]   
See also in sourсe #XX -- [ Pg.32 , Pg.412 ]




SEARCH



Analysis semi-automatic reaction

Clay semi-quantitative analysis

Convolutive or semi-integral analysis

Inductively coupled plasma mass semi-quantitative analysis

QUALITATIVE AND SEMI-QUANTITATIVE RISK ANALYSIS

Risk assessment process semi-quantitative analysis

Risk assessment semi-quantitative analysis (level

Semi-Empirical Flow Analysis

Semi-quantitative CDF Analysis. An Example

Semi-quantitative analysis

Semi-quantitative risk analysis

Semi-quantitative risk analysis example

Semi-quantitative risk analysis techniques

© 2024 chempedia.info