Scanning electron microscopy sample preparation

Scanning Electron Microscopy. Samples of unweathered and weathered untreated and formaldehyde-treated wools were mounted or specimen stubbs using conducting silver paint and coated with two thin layers of silver. Scanning electron micrographs of the samples were prepared and examined for changes In the fiber surface (Fig. 1). [Pg.286]

In contrast to many other surface analytical techniques, like e. g. scanning electron microscopy, AFM does not require vacuum. Therefore, it can be operated under ambient conditions which enables direct observation of processes at solid-gas and solid-liquid interfaces. The latter can be accomplished by means of a liquid cell which is schematically shown in Fig. 5.6. The cell is formed by the sample at the bottom, a glass cover - holding the cantilever - at the top, and a silicone o-ring seal between. Studies with such a liquid cell can also be performed under potential control which opens up valuable opportunities for electrochemistry [5.11, 5.12]. Moreover, imaging under liquids opens up the possibility to protect sensitive surfaces by in-situ preparation and imaging under an inert fluid [5.13]. [Pg.280]

Scanning electron microscopy and replication techniques provide information concerning the outer surfaces of the sample only. Accurate electron microprobe analyses require smooth surfaces. To use these techniques profitably, it is therefore necessary to incorporate these requirements into the experimental design, since the interfaces of interest are often below the external particle boundary. To investigate the zones of interest, two general approaches to sample preparation have been used. [Pg.39]

The authors wish to acknowledge the work of Paul McCarthy in scanning electron microscopy, Michael Saculla in x-ray radiography, and Steven Buckley and Chuck Chen in sample preparation and modulus measurement. This work was performed under the auspices of the U.S. Department of Energy by the Lawrence Livermore National Laboratory under Contract No. W-7405-ENG-48. [Pg.86]

Suhtnicion nickel powders luive been synthesized successfully from aqueous NiCh at various tempmatuTKi and times with ethanol-water solvent by using the conventional and ultrasonic chemical reduction method. The reductive condition was prepared by flie dissolution of hydrazine hydrate into basic solution. The samples synthesized in various conditions weae claractsiz by the m ins of an X-ray diffractometry (XRD), a scanning electron microscopy (SEM), a thermo-gravimetry (TG) and an X-ray photoelectron spectroscopy (XPS). It was found that the samples obtained by the ultrasonic method were more smoothly spherical in shape, smaller in size and narrower in particle size distribution, compared to the conventional one. [Pg.773]

This technique can be applied to samples prepared for study by scanning electron microscopy (SEM). When subject to impact by electrons, atoms emit characteristic X-ray line spectra, which are almost completely independent of the physical or chemical state of the specimen (Reed, 1973). To analyse samples, they are prepared as required for SEM, that is they are mounted on an appropriate holder, sputter coated to provide an electrically conductive surface, generally using gold, and then examined under high vacuum. The electron beam is focussed to impinge upon a selected spot on the surface of the specimen and the resulting X-ray spectrum is analysed. [Pg.369]

Our investigation of sNPS showed that the samples prepared by the chemical etching method described above have consistent photoluminescence, conductivity and photoconductivity properties, which have remained unchanged over 5 years. sNPS structure was investigated by scanning electronic microscopy (Fig. 9.1). [Pg.89]

Optical microscopy and scanning electron microscopy (SEM) were used to evaluate the drug incorporation and surface shape of the microspheres prepared under the various conditions. Particle size was determined using a Tiyoda microscope. Samples of microspheres (180-200) were dispersed on a slide and their diameter was then sized using suitable objectives. [Pg.105]

The consolidated titanate waste pellets are similar in appearance to their glass counterparts, i.e., both are dense, black and apparently homogeneous. Microscopic analyses, however, reveal important differences between these two waste forms. While little definitive work has been done with glassy waste forms, it is apparent that several readily soluble oxide particulates of various nuclides are simply encapsulated in the glass matrix. The titanate waste form has undergone extensive analyses which includes optical microscopy, x-ray, scanning electron microscopy, microprobe, and transmission electron microscopy (l ) The samples of titanate examined were prepared by pressure sintering and consisted of material from a fully loaded titanate column. Zeolite and silicon additions were also present in the samples. [Pg.139]

Recently, scanning electron microscopy has been used in our laboratory to investigate the effects of abrasion on the morphology of fibrous cellulose copolymers (36). For example, cotton cellulose was woven into fabric form (print cloth construction and weight). Cellulose copolymer fabrics were prepared by irradiating a sample of this fabric, followed by copolymerization of the irradiated fabric with a binary mixture of acrylo-... [Pg.338]

Wet samples can be analyzed without a previous preparation by the so-called environmental scanning electron microscopy (ESEM). In this technique, instead of the vacuum conditions, the sample chamber is kept in a modest gas pressure (Bache and Donald, 1998). The upper part of the column (illumination source) is kept in high vacuum conditions. A system of differential pumps allows to create a pressure gradient through the column (Bache and Donald, 1998 Stokes and Donald, 2000). The choice of the gas depends on the kind of food hydrated food is kept under water vapor. [Pg.218]


See other pages where Scanning electron microscopy sample preparation is mentioned: [Pg.377]    [Pg.377]    [Pg.152]    [Pg.151]    [Pg.464]    [Pg.127]    [Pg.308]    [Pg.242]    [Pg.202]    [Pg.486]    [Pg.177]    [Pg.19]    [Pg.10]    [Pg.600]    [Pg.151]    [Pg.160]    [Pg.483]    [Pg.131]    [Pg.142]    [Pg.189]    [Pg.341]    [Pg.444]    [Pg.211]    [Pg.190]    [Pg.12]    [Pg.13]    [Pg.72]    [Pg.118]    [Pg.278]    [Pg.306]    [Pg.1554]    [Pg.16]    [Pg.343]    [Pg.18]    [Pg.208]    [Pg.306]    [Pg.479]    [Pg.277]   
See also in sourсe #XX -- [ Pg.203 ]




SEARCH



Electron microscopy sample preparation

Electron samples

Sample electron microscopy

Sample microscopy

Sample scanning electron

Sampling microscopy

Scanning electron microscopy

Scanning electron microscopy sample

Scanning electronic microscopy

Scanning preparation

Scanning sample preparation

© 2024 chempedia.info