Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Sample Archive

In many cases, sample archives have proven to be very useful. Analytical techniques have been developed, making it possible to determine concentrations of new elements and other parameters and there are often new needs for information [Pg.10]

Alexander, J., and Marriott, S. B. (1999). Introduction. In Floodplains Interdisciplinary Approaches (S. B. Marriott andj. Alexander, eds.), pp. 1—13. The Geological Society, London, Special Publ. No. 163. [Pg.11]

Bplviken, B., Bergstrom, J., Bjorklund, A., Kontio, M., Ottesen, R. T., Steenfelt, A., and Volden, T. (1986). Geochemical Adas of Northern Fennoscandia. Scale 1 4 000 000. Geological surveys of Finland, Greenland, Norway and Sweden, 19 p. 155 map sheets. [Pg.11]

Bradshaw, P. M. D., Clews, D. R., and Walker, J. L. (1972). Exploration geochemistry A series of seven articles. Reprinted from Mining in Canada and Canadian Mining Journal. Barringer Research Ltd., Toronto, Ontario, 49 p. [Pg.11]

Darnley, A. G., Bjorklund, A., Bolviken, B., Gustavsson, N., Koval, P. V., Plant, J. A., Steenfelt, A., Tauchid, M., and Xie, X. (1995). A global geochemical database for environmental and resource management. Final report of IGCP Project 259. In Earth Sciences. Vol. 19, 122 pp. UNESCO Publishing, Paris. [Pg.11]


I. Howarth, A modem view of the past verifying the work of pioneering organic chemists through examination of remnants of their sample archives ,./. Chem. Educ., 1994, 71, 726-729. [Pg.75]

A variety of biomarkers have been shown to be valuable individually for one or several toxicant or disease situations. Few of these biomarkers have been systematically evaluated for the plethora of situations that might provoke false positive responses. Acceleration of the current pace of biomarker evaluation and qualification demands (a) the availability of panels of biomarker-assays that can be comparatively evaluated on well-defined common sample sets, (b) fit-for-purpose performance evaluation in controlled animal studies with carefully benchmarked histological endpoints and samples from well-defined focused clinical trial cohorts, and (c) ready availability of banked blood and urine sample archives from clinical trial populations with carefully documented morbidities such as the Framingham Heart Study,45 or the Drug-Induced Liver Injury Network (DILIN) prospective study,46 to name a few. Availability of such panels of validated biomarker assays and well-documented preclinical and clinical samples, as well as increased cooperation between animal model researchers and clinical researchers will enable individual biomarkers to be qualified for sensitivity of specifically defined adverse events, qualified for appropriate specificity using samples of defined benign events, and collected into panels that yield complementary information about the health and safety of animals and patients. [Pg.310]

For each specimen collected in the selected site the sample archiving database is displayed in a window (see Figure 12.7) showing the following data ... [Pg.314]

Contamination. Contamination of samples by external sources can be a serious source of error and may be extremely variable. An excellent example of how serious this can be has been documented in the analysis of samples for polychlorinated biphenyls (PCBs). PCBs are synthetic mixtures of organochlorine compounds that were first manufactured in 1929 and have become of concern as significant environmental pollutants. It has been demonstrated that samples archived since 1914, before PCBs were manufactured, picked up measurable amounts of PCBs in a few hours just sitting in a modem laboratory (Erickson). Aluminum levels in the dust in a normal laboratory are so high that dust prohibits the determination of low ppb levels of aluminum in samples. A special dust-free clean lab or clean bench with a filter to remove small dust particles may be required, similar to the clean rooms needed in the semiconductor industry, for determination of traces of aluminum, silicon, and other common elements such as iron. When trace (inorganic analysis is required, the laboratory environment can be a significant source of contamination. [Pg.29]

In conclusion, nano-LC combined with further improvements in MS sensitivity and speed will continue to reduce whole proteome analysis time for microbial strains by producing tens of thousands of peptide sequence-to-spectrum matches (PSMs) in less than 1 h (Hebert et al. 2014). However, LC-MALDI-MS/MS analyses may be better suited for specific applications requiring sample archiving. [Pg.99]

A First targeted analysis of ambient air for an illicit drug cocaine quantified in particulates from all air sampled around Rome and several other Mediterranean locations (also in air samples archived several years prior) Cecinato and Balducci (2007)... [Pg.6]

Sample scan data is a good way to archive the results of an inspection. The inspection could be re-visited later to see how the eddy-current response has changed over time. Random audits of the quality of inspection detection could be monitored. The inspection could also be reviewed if new information becomes known, say from inspection conducted using alternate methods. [Pg.1020]

The historical data is sampled at user-specified intervals. A typical process plant contains a large number of data points, but it is not feasible to store data for all points at all times. The user determines if a data point should be included in the list of archive points. Most systems provide archive-point menu displays. The operators are able to add or delete data points to the archive point hsts. The samphng periods are normally some multiples of their base scan frequencies. However, some systems allow historical data samphng of arbitraiy intei vals. This is necessaiy when intermediate virtual data points that do not have the scan frequency attribute are involved. The archive point lists are continuously scanned bv the historical database software. On-line databases are polled for data. The times of data retrieval are recorded with the data ootained. To consei ve storage space, different data compression techniques are employed by various manufacturers. [Pg.773]

Tokunaga R, Takahata S, Onoda M, Ishi-i T, Sato K (1974) Evaluation of the exposure to organic solvent mixture. Comparative studies on detection tube and gas-liquid chromatographic methods, personal and stationary sampling, and urinary metabolite determination. Internationales Archiv Arbeitsmedizin 33 257-267. [Pg.234]

Copies of the final sampling reports must be submitted to the headquarters of JPPA and two analytical laboratories, immediately after the trial is finished. The original of the final sampling report should be archived at the trial site. [Pg.47]

This section discusses treatment of the water samples in preparation for instrumental analysis after they have been received, archived and stored in the laboratory. Many approaches may be taken in preparation of water samples for final analysis. The techniques employed will depend upon the type of matrix, e.g., groundwater vs surface water (containing organic materials), the instrumental method and the required detection limits. [Pg.821]

Purity analysis and characterization of the test substance should be performed for each lot. A retention sample from each batch of the test substance should be archived. All unused test substance and partially empty containers should be retained until the final report is signed, unless a prior waiver has been obtained from the EPA. [Pg.963]

There is little doubt on the basis of the above review that speleothems are useful in an extremely wide range of applications and the frequency of publications devoted to speleothem-based archives is increasing rapidly. Fundamental to all applications is a robust and high-precision chronology and uranium-series techniques currently set the standard in this regard for speleothems. Reliable ages can be obtained for most samples where material appears to be well-preserved. However, it will become increasingly important to demonstrate reliability as the spatial resolution of analysis improves further. [Pg.449]


See other pages where Sample Archive is mentioned: [Pg.1]    [Pg.10]    [Pg.193]    [Pg.196]    [Pg.196]    [Pg.197]    [Pg.26]    [Pg.286]    [Pg.160]    [Pg.282]    [Pg.1]    [Pg.10]    [Pg.193]    [Pg.196]    [Pg.196]    [Pg.197]    [Pg.26]    [Pg.286]    [Pg.160]    [Pg.282]    [Pg.183]    [Pg.773]    [Pg.312]    [Pg.261]    [Pg.5]    [Pg.5]    [Pg.122]    [Pg.58]    [Pg.175]    [Pg.159]    [Pg.192]    [Pg.24]    [Pg.7]    [Pg.202]    [Pg.204]    [Pg.318]    [Pg.931]    [Pg.396]    [Pg.407]    [Pg.408]    [Pg.450]   


SEARCH



Archival

Archival samples

Archiving

© 2024 chempedia.info