Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Resolution visual

AMD is a deterioration of the central portion of the retina (the macula). The macula facilitates central vision and high-resolution visual acuity because it has the highest concentration of photoreceptors in the retina. The loss of central... [Pg.942]

Parra, I. and Windle, B (1993) High-resolution visual mapping of stretched DNA by fluorescent hybridization. Nature Genet. 5, 17—21. [Pg.418]

Low-resolution visual analysis of surfaces High-resolution analysis of surfaces using high-energy electrons that cause resident electrons to be ejected. When these are detected, they can be converted into an image... [Pg.4592]

High-resolution visualization strictly limited to the laryngeal lumen and mucous surface Three-dimensional (3D) information on anatomical structures and pathologic processes beyond the mucosal surface demonstrates the extent of disease, as well as the involvement of surrounding vessels... [Pg.184]

Cons Low beam intensities (low time and spatial resolution) Visualization of light elements in the presence of metals Low beam intensities... [Pg.495]

This technique demonstrates the potential in combining the spatial specificity of microscopy with the powerful chemical specificity of spectroscopy. A balance between the need for sensitive spectral information and a need for high spatial resolution visualization is also necessary for morphological characterization. Hence, infrared microspectroscopy is performed in sequence with emphasis placed on instrumentation capabilities and experimental possibilities. [Pg.628]

Keywords Resolution Visual acuity MTF (Modulation Transfer Function) SFR (Spatial Frequency Response) Line widths per picture height Resolution chart Image height Nominal spatial frequency Normalized spatial frequency... [Pg.101]

Laminographical approaches can be used for layer-by-layer visualization of the internal microstructure for the flat objects (multilayers, PCBs etc.), that caimot be reconstructed by computerized tomography because of the limited possibilities in rotation. Depth and lateral spatial resolutions are limited by the tube, camera and rotation accuracy. Microfocus X-ray tubes and digital registration techniques with static cameras allow improving resolution. Precision object manipulations and more effective distortion corrections can do further improvement. [Pg.572]

In order to maintain Class and to comply with international legislation a ship must undergo surveys at prescribed intervals. Ships such as tankers and bulk carriers must comply with International Maritime Organisation resolutions which require a Class Enhanced Survey Programme. This programme includes Special Surveys at five yearly intervals with close-up visual inspection and thickness measurements to be made at specified locations, the number of which increases with the age of the ship. [Pg.1045]

Otlier fonns of microscopy have been used to evaluate nanocrystals. Scanning electron microscopy (SEM), while having lower resolution tlian TEM, is able to image nanoparticles on bulk surfaces, for direct visualization of... [Pg.2905]

A completely new method of determining siufaces arises from the enormous developments in electron microscopy. In contrast to the above-mentioned methods where the surfaces were calculated, molecular surfaces can be determined experimentally through new technologies such as electron cryomicroscopy [188]. Here, the molecular surface is limited by the resolution of the experimental instruments. Current methods can reach resolutions down to about 10 A, which allows the visualization of protein structures and secondary structure elements [189]. The advantage of this method is that it can be apphed to derive molecular structures of maaomolecules in the native state. [Pg.129]

Under certain conditions the sample is clearly visible throughout the process. Other times it is necessary to stain the matrix to visualize the components. In cases where a final staining procedure is required, a small amount of dye is often added to the sample before the analysis. The dye typically migrates faster than any sample component. The position of the dye in the matrix indicates the speed of the resolution of the components of the sample. Typically, the electrophoretic medium is discarded after use. Good resolution can be obtained from 1 to 20 hours, using applied voltages of 10 to 2000 V and currents of 5 to 100 m A. [Pg.180]

Good semi-quantitative agreements are found in diffraction patterns and proposed models obtained by molecular-dynamics[14], because the results of the ex-periments[31-34] are consistent with the atomic models proposed by us[14]. However, in the present state of high-resolution electron microscopy, taking into account, moreover, the number of sheets and the complicated geometry of the helix, it seems unlikely to directly visualize the pentagon-hexagon pairs. [Pg.84]

Since a considerable amount of review articles on both theoretical frameworks and calculated results have been reported[15-25], the main objective of the present study is placed on the comparisons with experimental results. The organization of the present report is as follows In the next section, for the sake of completeness, a brief theoretical description of the PPM is summarized from the previous articles. In the third section, disorder-LIq transition is focused and visualized atomic (spin) configuration is compared with recent high resolution electron micrograph. In the fourth section, ordering relaxation... [Pg.84]


See other pages where Resolution visual is mentioned: [Pg.333]    [Pg.33]    [Pg.289]    [Pg.20]    [Pg.115]    [Pg.127]    [Pg.159]    [Pg.23]    [Pg.140]    [Pg.117]    [Pg.240]    [Pg.858]    [Pg.259]    [Pg.333]    [Pg.33]    [Pg.289]    [Pg.20]    [Pg.115]    [Pg.127]    [Pg.159]    [Pg.23]    [Pg.140]    [Pg.117]    [Pg.240]    [Pg.858]    [Pg.259]    [Pg.449]    [Pg.472]    [Pg.539]    [Pg.697]    [Pg.1623]    [Pg.1656]    [Pg.1829]    [Pg.269]    [Pg.198]    [Pg.204]    [Pg.460]    [Pg.36]    [Pg.354]    [Pg.308]    [Pg.251]    [Pg.109]    [Pg.180]    [Pg.7]    [Pg.67]    [Pg.133]    [Pg.284]    [Pg.1080]   
See also in sourсe #XX -- [ Pg.56 , Pg.64 , Pg.65 ]




SEARCH



Enantiomers visual resolution

Spatial resolution visualization

© 2024 chempedia.info