Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Records modification

The use of time-stamped audit trails (Part 11.10(c) and (e) to keep track of any record modifications carried out by the database administrator. [Pg.110]

Audit trails refer to a journal that records modifications to electronic records. The persons or automated processes operating on the user s behalf may perform these modifications. The audit-trail mechanism provides the capability to reconstruct the data prior to a modification, and therefore must not obscure the previously recorded data. The tracking mechanism must include a computer-generated time stamp that indicates the time of the entry. Audit trails are computer generated and can be part of the record that has been modified or a standalone record linked to the modified record. [Pg.115]

Interaction between a fluorophore and a molecule or between two molecules induces usually perturbation or modification in the fluorescence parameters such as intensity, quantum yield or/ and lifetime. These fluorescence perturbations will allow to explain and to understand the nature and the origin of interactions between the different molecules. Since we are applying fluorescence measurements to follow these interactions, then one should expect to record modifications occurring within the range of the fluorescence lifetime. [Pg.141]

The application of load in materials produces internal modifications such as crack growth, local plastic deformation, corrosion and phase changes, which are accompanied by the emission of acoustic waves in materials. These waves therefore contain information on the internal behaviour of the material and can be analysed to obtain this information. The waves are detected by the use of suitable sensors, that converts the surface movements of the material into electric signal. These signals are processed, analysed and recorded by an appropriate instrumentation. [Pg.31]

Additional assistance is provided by secondary modification options that allow among others for a depiction of the original signal, the reconstruction of the depiction of the impedance plane of the eddy-current signals or for modifications of phase, amplification or zero point virtually in real time. That way, once C-scan images have been recorded, they can now be evaluated as needed without having to repeat the test. [Pg.309]

The fir.-fit line of the file (see Figure 2-110) - the HEADER record - hold.s the moleculc. s classification string (columns 11-50), the deposition date (the date when the data were received by the PDB) in columns 51-59, and the PDB (Dcode for the molecule, which is unique within the Protein Data Bank, in columns 63-66. The second line - the TITLE record - contains the title of the experiment or the analysis that is represented in the entry. The subsequent records contain a more detailed description of the macromolecular content of the entiy (COMPND), the biological and/or chemical source ofeach biological molecule in the entiy (SOURCE), a set ofkeywords relevant to the entiy (KEYWDS). information about the experiment (EXPDTA), a list of people responsible for the contents of this entiy (.AUTHOR), a history of modifications made to this entiy since its release (REVDAT), and finally the primaiy literature citation that describes the experiment which resulted in the deposited dataset ()RNL). [Pg.115]

After obtaining the described decomposition the set of equations can be readily solved. This is because all of the information required for transfonnation of the coefficient matrix to an upper triangular fonn is essentially recorded in the lower triangle. Therefore modification of the right-hand side is quite straightforward and can be achieved using the lower triangular matrix as... [Pg.204]

The safety review report is distributed to the committee which meets to work its way through the report, section by section, discussing safety concerns and potential improvements to the process or procedure. An individual must be designated to take minutes at the meeting and record suggested modifications. If the review concerns an existing process, the committee should perform a site visit to examine the actual equipment. [Pg.470]

The EPIDOS Register available direcdy on the EPIDOS computer is unique in providing behind-the-scenes information, such as the expected date of grant for a pending patent apphcation, and a record of correspondence between examiner and apphcant. This file is somewhat user-unfriendly, and as a result probably has limited use however, modifications that could increase its use are likely. [Pg.61]

Provide employee accident experience for the past 5 years, including the current year. The submittal shall specifically include OSHA recordable cases rate, lost and restricted workday cases rate, vehicle accident rate, and number of fatalities with a description of each. The workers compensation interstate experience modification rate should be less than 1.0, and applicable SIC codes should be noted. [Pg.217]

The records to be produced as evidence that the modification has been embodied (see also clause 4.5.2.2 of ISO/TS 16949)... [Pg.273]

Create and maintain records of the embodiment of modifications in production. [Pg.277]

Are recorded and maintained indicating their serviceability and their design standards, including records of repairs and modifications. [Pg.530]

Let us examine some batch results. In trials in which 5 mL of a dye solution was added by pipet (with pressure) to 10 mL of water in a 25-mL flask, which was shaken to mix (as determined visually), and the mixed solution was delivered into a 3-mL rectangular cuvette, it was found that = 3-5 s, 2-4 s, and /obs 3-5 s. This is characteristic of conventional batch operation. Simple modifications can reduce this dead time. Reaction vessels designed for photometric titrations - may be useful kinetic tools. For reactions that are followed spectrophotometrically this technique is valuable Make a flat button on the end of a 4-in. length of glass rod. Deliver 3 mL of reaction medium into the rectangular cuvette in the spectrophotometer cell compartment. Transfer 10-100 p.L of a reactant stock solution to the button on the rod. Lower this into the cuvette, mix the solution with a few rapid vertical movements of the rod, and begin recording the dead time will be 3-8 s. A commercial version of the stirrer is available. [Pg.177]

When the temperature of the analyzed sample is increased continuously and in a known way, the experimental data on desorption can serve to estimate the apparent values of parameters characteristic for the desorption process. To this end, the most simple Arrhenius model for activated processes is usually used, with obvious modifications due to the planar nature of the desorption process. Sometimes, more refined models accounting for the surface mobility of adsorbed species or other specific points are applied. The Arrhenius model is to a large extent merely formal and involves three effective (apparent) parameters the activation energy of desorption, the preexponential factor, and the order of the rate-determining step in desorption. As will be dealt with in Section II. B, the experimental arrangement is usually such that the primary records reproduce essentially either the desorbed amount or the actual rate of desorption. After due correction, the output readings are converted into a desorption curve which may represent either the dependence of the desorbed amount on the temperature or, preferably, the dependence of the desorption rate on the temperature. In principle, there are two approaches to the treatment of the desorption curves. [Pg.346]

OSHA. 1982. Access to employee exposure and medical records proposed modification request for comments and notice of public hearing. Occupational Safety and Health Administration. Federal Register 47 30420. [Pg.309]

Maintenance embraces regular inspection, periodic examination by competent persons , and repairs. All maintenance on equipment used with chemicals should be properly planned and recorded. Maintenance operations, particularly those which are non-routine, require a sound system of work with strict administrative procedures, e.g. permit-to-work, to avoid risks arising from modifications to established safe practices. A permit-to-work should be used wherever the method by which a job is done is likely to be critical to the safety of the workers involved, nearby workers, or the public it is required whenever the safeguards provided in normal operations are no longer available. Examples include ... [Pg.282]

Procedures should be established to periodically monitor all operations that may have an environmental impact, and similar scheduled periodic checks should be made to ensure that procedures and operations are still in line with regulatory and other requirements. If equipment is involved in the monitoring process then procedures should also be in place to ensure correct calibration. Procedures are also needed to record any preventative or corrective actions identified and to ensure that they are completed to schedule. The whole EMS should be audited periodically to check that it is consistent with the planned policy and has been properly implemented. The details of audits should be discussed and reviewed by management at the highest level with a view to continuous improvement through the modification of both policy and procedures. [Pg.52]

Hi) Sulfamates.—The two most well known sweet compounds in this class are cyclamate (9) and saccharin (10). Considerable structural modifications have been recorded, and their tastes ascertained. [Pg.297]


See other pages where Records modification is mentioned: [Pg.739]    [Pg.739]    [Pg.2615]    [Pg.237]    [Pg.494]    [Pg.197]    [Pg.389]    [Pg.409]    [Pg.107]    [Pg.417]    [Pg.444]    [Pg.439]    [Pg.507]    [Pg.261]    [Pg.297]    [Pg.298]    [Pg.146]    [Pg.789]    [Pg.36]    [Pg.289]    [Pg.370]    [Pg.208]    [Pg.246]    [Pg.189]    [Pg.396]    [Pg.397]    [Pg.51]    [Pg.262]    [Pg.825]    [Pg.441]    [Pg.417]   